Daniel Kwasi Amponsah

Dr. Daniel Kwasi Amponsah

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2022 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
DCDaniela R. Crousillat
Daniela R. Crousillat
DADaniel Kwasi Amponsah
Daniel Kwasi Amponsah
ACAlexander Camacho
Alexander Camacho
RKRitvik R. Kandanelly
Ritvik R. Kandanelly
DBDevavrat Bapat
Devavrat Bapat
SESammy Elmariah
Sammy Elmariah
Background: Racial and ethnic minority groups are underrepresented among patients undergoing aortic valve replacement in the United States. We evaluated the impact of race and ethnicity on the diagnosis of aortic stenosis (AS). Methods and Results: In patients with transthoracic echocardiography (TTE)‐confirmed AS, we assessed rates of AS diagnosis as defined by assignment of an International Classification of Diseases, Ninth Revision (ICD‐9) and Tenth Revision (ICD‐10) code for AS within a large multicenter electronic health record. Multivariable Cox proportional hazard and competing risk regression models were used to evaluate the 1‐year rate of AS diagnosis by race and ethnicity. Among 14 800 patients with AS, the 1‐year diagnosis rate for AS following TTE was 37.4%. Increasing AS severity was associated with an increased likelihood of receiving an AS diagnosis (moderate: hazard ratio [HR], 3.05 [95% CI, 2.86–3.25]; P <0.0001; severe: HR, 4.82 [95% CI, 4.41–5.28]; P <0.0001). Compared with non‐Hispanic White, non‐Hispanic Black (HR, 0.65 [95% CI, 0.54–0.77]; P <0.0001) and non‐Hispanic Asian individuals (HR, 0.72 [95% CI, 0.57–0.90], P =0.004) were less likely to receive a diagnosis of AS. Additional factors associated with a decreased likelihood of receiving an AS diagnosis included a noncardiology TTE ordering provider (HR, 0.92 [95% CI, 0.86–0.97]; P =0.005) and TTE performed in the inpatient setting (HR, 0.72 [95% CI, 0.66–0.78]; P <0.0001). Conclusions: Rates of receiving an ICD diagnostic code for AS following a diagnostic TTE are low and vary significantly by race and ethnicity and disease severity. Further studies are needed to determine if efforts to maximize the clinical recognition of TTE‐confirmed AS may help to mitigate disparities in treatment.

6 February 2026 in Nature Medicine
Verified
Journal Article
Open access
PDF file
JOJack W. O’SUllivan
Jack W. O’SUllivan
APAnil Palepu
Anil Palepu
KSKhaled Saab
Khaled Saab
WWWei-Hung Weng
Wei-Hung Weng
DADaniel Kwasi Amponsah
Daniel Kwasi Amponsah
TTTao Tu
Tao Tu
The scarcity of subspecialist medical expertise poses a considerable challenge for healthcare delivery. This issue is particularly acute in cardiology, where timely, accurate management determines outcomes. We explored the potential of Articulate Medical Intelligence Explorer (AMIE), a large language model-based experimental medical artificial intelligence system, to augment clinical decision-making in this challenging context. We conducted a randomized controlled trial comparing large language model-assisted care with the usual care of complex patients suspected of having a genetic cardiomyopathy, and we curated a real-world dataset of complex cases from a subspecialist cardiology practice. Nine participating general cardiologists were provided with access to both clinical text reports and raw diagnostic data—including electrocardiograms, echocardiograms, cardiac magnetic resonance imaging scans and cardiopulmonary exercise testing—and were randomized to manage these cases, either with or without assistance from AMIE. We developed a ten-domain evaluation rubric used by three blinded subspecialists to evaluate the quality of triage, diagnosis and management. In our randomized controlled trial with retrospective patient data, subspecialists favored large language model-assisted responses overall, and for the management plan and diagnostic testing domains, with the remaining domains considered a tie. Overall, subspecialists preferred AMIE-assisted cardiology assessments 46.7% of the time, compared with 32.7% for cardiologists alone ( P = 0.02), with 20.6% rated as a tie. Subspecialists also quantified errors, extra and missing content, reasoning and potential bias. Cardiologists alone had more clinically significant errors (24.3% versus 13.1%, P = 0.033) and more missing content (37.4% versus 17.8%, P = 0.0021) than cardiologists assisted by AMIE. Lastly, cardiologists who used AMIE reported that AMIE helped their assessment more than half the time (57.0%) and saved time in 50.5% of cases.

16 July 2024 in Circulation
Verified
Journal Article
Closed access
NSNancy Song
Nancy Song
TBTariku J. Beyene
Tariku J. Beyene
DADaniel Kwasi Amponsah
Daniel Kwasi Amponsah
SASteven M. Asch
Steven M. Asch
PHPaul Heidenreich
Paul Heidenreich
CYCelina M. Yong
Celina M. Yong

20 November 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DADaniel Kwasi Amponsah
Daniel Kwasi Amponsah
WFWilliam F Fearon
William F Fearon
Angiography-derived physiology (ADP) has emerged as a validated, wire-free method for the functional assessment of coronary artery disease (CAD). By avoiding pressure-wire instrumentation and hyperemic agents, ADP reduces procedure time, radiation exposure, and cost, while maintaining strong diagnostic performance with invasive physiology. These platforms include FFRangio (CathWorks), QFR (Medis Medical Imaging), and vFFR (Pie Medical Imaging), which have undergone extensive validation and are FDA approved for use. Randomized trials, predominantly with QFR, thus far demonstrate improved outcomes of ADP-guided strategies compared with angiography alone, whereas non-inferiority to wire-based FFR guidance has not yet been established. As clinical trials continue, thoughtful integration into routine practice requires careful image acquisition, platform-specific training, and awareness of limitations. In particular, validation remains incomplete in complex subsets such as left main disease, bifurcations, and bypass grafts, though evidence is growing in the application in acute coronary syndromes, post-PCI prognostication, and surgical planning. As ongoing studies mature and ADP technology evolves, these tools are poised to reshape physiologic assessment, streamline catheterization laboratory workflow, and become integral to contemporary PCI planning and optimization. This review summarizes current evidence, clinical applications, limitations, integration into the catheterization lab, and future directions of ADP.

17 April 2026 in JACC: Advances
Verified
Journal Article
Open access
SSShirin Sadri
Shirin Sadri
DADaniel Kwasi Amponsah
Daniel Kwasi Amponsah
TBTariku J. Beyene
Tariku J. Beyene
TBThomas A. Burdon
Thomas A. Burdon
WFWilliam F. Fearon
William F. Fearon
CYCelina M. Yong
Celina M. Yong

10 March 2026 in JACC: Case Reports
Verified
Journal Article
Open access
SHSofia Hu
Sofia Hu
DADaniel Kwasi Amponsah
Daniel Kwasi Amponsah
SMSachin Malik
Sachin Malik
Patricia NguyenPatricia Nguyen
Patricia Nguyen
NMNeha Mantri
Neha Mantri
GKGuson Kang
Guson Kang
Infolding is a known complication of self-expandable transcatheter valves that typically causes hemodynamic compromise. Delayed diagnosis of infolding is rare and can result in premature leaflet degeneration, with limited treatment options. A 71-year-old man presented 5 years after transcatheter aortic valve replacement (TAVR) with severe intravalvular regurgitation. Transesophageal echocardiography revealed significant infolding of the valve. The patient underwent valve-in-valve TAVR, which successfully resolved the aortic insufficiency. This is the first reported case of a chronically infolded TAVR, which is a rare but significant complication of self-expandable valves. We demonstrate that valve-in-valve replacement can successfully overcome chronic frame distortion and endothelialization. Transcatheter valve infolding does not necessarily cause significant hemodynamic changes, which can lead to delays in diagnosis and treatment. Chronic infolding can be visualized by 3D computed tomography and can result in premature leaflet degeneration. Structural distortion of self-expandable valves, even years after implant, can be overcome with high-pressure valvuloplasty and valve-in-valve replacement.