Panida Lorwongtragool

Dr. Panida Lorwongtragool

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WKWarunee Krudpun
Warunee Krudpun
NCNonchanutt CHUDPOOTI
Nonchanutt CHUDPOOTI
PLPanida Lorwongtragool
Panida Lorwongtragool
SSSomporn Seewattanapon
Somporn Seewattanapon
PAPrayoot Akkaraekthalin
Prayoot Akkaraekthalin
This paper presents, for the first time, a microwave gas sensor utilizing Poly (styrene-co-maleic acid) partial isobutyl/methyl mixed ester (PSE), which is a sensing material, as a coating on an interdigital resonator. The proposed sensor is based on a near-field transmission-line technique to detect the changing of the dielectric properties of the sensing material. The sensor was designed based on a DiClad 880 substrate with an interdigital resonator, operating at 4 GHz, on the middle of an ungrounded coplanar waveguide transmission line structure with rejection characteristic by coating the PSE solution as a sensed-gas material. The measured transmission coefficient, S21, was changed depending on the dielectric properties of the PSE change due to various concentrations of gas targeted in a range of 50 to 1,000 ppm (50 ppm, 200 ppm, 500 ppm, 1,000 ppm) under a static system in a closed chamber at room temperature. The extracted results of differential transmission coefficient change, S21, from four samples of ammonia concentration can be separated impressively. To confirm the selectivity performance of ammonia gas, three interfering gases, i.e., acetone, ethanol and methanol, were investigated. The measured results show that the proposed sensor can discriminate ammonia gas from three interfering gases over the entire concentration range in only three minutes. Moreover, it has many advantages, such as low cost, real-time monitoring and room temperature operating. The PSE-coated sensor described in this paper is suitable for a high-performance selectivity in ammonia gas sensing applications both in industrial processes and in agricultural products.

29 October 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PLPanida Lorwongtragool
Panida Lorwongtragool
SLSuthisa Leasen
Suthisa Leasen
This study presents a cost-effective and accurate method for assessing nitrogen concentration in vermicompost fertilizer using a low-cost TCS3200 color sensor and a K-Nearest Neighbors (KNN) machine learning model. The objective was to evaluate the performance of four different color spaces—RGB, Lab, LCh, and CMYK—identify the most effective feature representation for a multi-class classification task based on accuracy and theoretical robustness to ambient light variations. A total of 2400 data points were collected from a standard chemical test kit and processed. A rigorous 60-fold cross-validation approach was used to determine the optimal model hyperparameters and to ensure the robustness of the findings. The results demonstrate that the model trained on the LCh color space achieved the highest classification accuracy of 0.9708 with an optimal K-value of 6, significantly outperforming Lab (0.9688), RGB (0.9625), and CMYK (0.9583). A detailed analysis of the confusion matrix revealed that the model successfully classified the ‘High’ and ‘Medium’ nitrogen levels with near-perfect accuracy, while minor misclassifications occurred between the ‘Low’ and ‘Trace’ categories (5 Low ⟶ Trace, 6 Trace ⟶ Low). The proposed system offers a practical, robust, and accessible tool for precision agriculture, enabling farmers to make informed decisions regarding fertilization, and directly supporting sustainable agriculture and responsible resource management. The findings indicate that the LCh color space is highly effective for this application, providing a viable solution for the rapid and reliable assessment of vermicompost quality. Most importantly, this inexpensive, on-site system removes the need for costly, time-consuming laboratory analyses, giving farmers and compost users the instantaneous, accurate nitrogen data they need to maximize crop yield, optimize nutrient application, and significantly reduce input costs from overfertilization.

2 February 2026 in Forensic Sciences
Verified
Journal Article
Open access
PDF file
SLSuthisa Leasen
Suthisa Leasen
PLPanida Lorwongtragool
Panida Lorwongtragool
Sittichoke ChaiwanSittichoke Chaiwan
Sittichoke Chaiwan
Montri DonphoongpriMontri Donphoongpri
Montri Donphoongpri
Background: In forensic ballistics, identifying ammunition types on physical evidence is critical, particularly when metallic residues are minimal. This study comparatively analyzes the elemental signatures deposited by two common projectiles—Full Metal Jacket (FMJ) (Cu/Zn jacket) and Lead Round Nose (LRN) (exposed Pb core)—on complex targets, including pig bone/tissue and mango wood. Methods: Using a semi-automatic handgun at an intermediate range of 5.0 m, residues were examined through high-resolution benchtop Micro-XRF (M4 Tornado) for micro-spatial analysis and Portable XRF (Elio) for rapid field characterization. Additionally, fresh pork leg samples were subjected to a 3-month environmental degradation period to assess trace persistence. Results: Observations indicated that LRN projectiles exhibit markedly elevated Lead (Pb) concentrations along the wound track in bone, hence confirming Pb as a reliable indicator for unjacketed ammunition; specifically, the median Pb concentrations at bullet wiping were 10.39 wt% for M4 and 7.34 wt% for Elio. Conversely, FMJ traces remain strictly confined to the surface bullet wipe area, with median concentrations of Pb, Cu, and Zn being 2.21 wt%, 0.24 wt%, and 0.59 wt% via M4, respectively. Statistical analysis showed a strong correlation for high-concentration elements on tissue, but significantly greater variance on wooden surfaces where FMJ traces exhibited a very weak negative correlation (r = −0.2774) due to minimal and irregular metal transfer. Taphonomic evaluation revealed that the Pb signature from LRN is exceptionally stable (r ≈ 0.9999) even after decomposition, while FMJ signatures are highly sensitive to environmental exposure. Conclusions: This research underscores the necessity of high-sensitivity Micro-XRF (M4) for definitive ammunition verification, providing a refined analytical framework for shooting incident reconstruction even involving degraded remains or complex environmental scenes.