This paper addresses the issue of fault diagnosis in high-speed train bogie bearings under complex working conditions and proposes a method for calculating the characteristic frequency of rolling bearings that takes into account the influence of radial clearance. By establishing a five-degree-of-freedom nonlinear dynamic model, this study systematically analyzes the modulation mechanism of radial clearance on the fault characteristic frequency of bearings and verifies the findings through an experimental platform. The results indicate that an increase in clearance not only leads to significant attenuation of the fault characteristic frequency amplitude, but also induces sideband modulation effects, thereby interfering with fault diagnosis accuracy. The experimental data show good agreement with the theoretical calculations, verifying the effectiveness of the proposed method. Specifically, the nonlinear stiffness-based characteristic frequency calculation reduces the prediction error from 6.9–5.7% under traditional theory to 2.3–3.4% across a wide range of rotational speeds. Meanwhile, the clearance-induced amplitude attenuation predicted by the model is also experimentally confirmed, with measured amplitude reductions of 35–42% as clearance increases from 0.2 μm to 0.5 μm. These results not only demonstrate the accuracy and engineering applicability of the method but also provide new theoretical foundations and practical references for health monitoring and early fault diagnosis of high-speed train bearings.
Objective: Lumbar interbody fusion (LIF) is widely used to treat degenerative spinal disorders; however, both fixation strategies and interbody Cage designs still present biomechanical limitations. This study aimed to develop a posterior lumbar interbody fusion Cage using topology optimization and to compare the biomechanical performance of oblique pedicle screw fixation with conventional fixation. Methods: A validated three-dimensional nonlinear finite element model of the L1–L5 lumbar spine was established based on CT data. A two-step weighted topology optimization was applied to the L3–L4 interbody Cage to determine both the external contour and the internal bone graft window. Finite element models with oblique pedicle screw fixation and conventional pedicle screw–rod fixation were constructed and evaluated under static physiological loads and whole-body vibration conditions. Results: Compared with the conventional Cage, the topology-optimized Cage combined with oblique fixation significantly reduced the maximum von Mises stress on adjacent endplates and decreased Cage displacement under both static and dynamic loading. Although stresses in the Cage and screws increased relative to traditional fixation, all values remained well below material yield limits. Conclusions: The combination of a topology-optimized Cage and oblique pedicle screw fixation improves load transfer and structural stability while reducing the risk of endplate damage and Cage subsidence. This approach provides a promising alternative design strategy for posterior lumbar interbody fusion.