Tomas Ward

Dr. Tomas Ward

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2007 in Journal of Neural Engineering
Verified
Journal Article
Closed access
SCShirley Coyle
Shirley Coyle
TWTomas Ward
Tomas Ward
CMCharles M Markham
Charles M Markham
A brain-computer interface (BCI) is a device that allows a user to communicate with external devices through thought processes alone. A novel signal acquisition tool for BCIs is near-infrared spectroscopy (NIRS), an optical technique to measure localized cortical brain activity. The benefits of using this non-invasive modality are safety, portability and accessibility. A number of commercial multi-channel NIRS system are available; however we have developed a straightforward custom-built system to investigate the functionality of a fNIRS-BCI system. This work describes the construction of the device, the principles of operation and the implementation of a fNIRS-BCI application, 'Mindswitch' that harnesses motor imagery for control. Analysis is performed online and feedback of performance is presented to the user. Mindswitch presents a basic 'on/off' switching option to the user, where selection of either state takes 1 min. Initial results show that fNIRS can support simple BCI functionality and shows much potential. Although performance may be currently inferior to many EEG systems, there is much scope for development particularly with more sophisticated signal processing and classification techniques. We hope that by presenting fNIRS as an accessible and affordable option, a new avenue of exploration will open within the BCI research community and stimulate further research in fNIRS-BCIs.

2 February 2023 in ACM Computing Surveys
Verified
Journal Article
Open access
EBEoin Brophy
Eoin Brophy
ZWZhengwei Wang
Zhengwei Wang
QSQi She
Qi She
TWTomas Ward
Tomas Ward
Generative adversarial network (GAN) studies have grown exponentially in the past few years. Their impact has been seen mainly in the computer vision field with realistic image and video manipulation, especially generation, making significant advancements. Although these computer vision advances have garnered much attention, GAN applications have diversified across disciplines such as time series and sequence generation. As a relatively new niche for GANs, fieldwork is ongoing to develop high-quality, diverse, and private time series data. In this article, we review GAN variants designed for time series related applications. We propose a classification of discrete-variant GANs and continuous-variant GANs, in which GANs deal with discrete time series and continuous time series data. Here we showcase the latest and most popular literature in this field—their architectures, results, and applications. We also provide a list of the most popular evaluation metrics and their suitability across applications. Also presented is a discussion of privacy measures for these GANs and further protections and directions for dealing with sensitive data. We aim to frame clearly and concisely the latest and state-of-the-art research in this area and their applications to real-world technologies.

22 February 2012 in IEEE Transactions on Information Technology in Biomedicine
Verified
Journal Article
Closed access
KSKevin T. Sweeney
Kevin T. Sweeney
TWTomas Ward
Tomas Ward
SMSean McLoone
Sean McLoone
The combination of reducing birth rate and increasing life expectancy continues to drive the demographic shift toward an aging population. This, in turn, places an ever-increasing burden on healthcare due to the increasing prevalence of patients with chronic illnesses and the reducing income-generating population base needed to sustain them. The need to urgently address this healthcare “time bomb” has accelerated the growth in ubiquitous, pervasive, distributed healthcare technologies. The current move from hospital-centric healthcare toward in-home health assessment is aimed at alleviating the burden on healthcare professionals, the health care system and caregivers. This shift will also further increase the comfort for the patient. Advances in signal acquisition, data storage and communication provide for the collection of reliable and useful in-home physiological data. Artifacts, arising from environmental, experimental and physiological factors, degrade signal quality and render the affected part of the signal useless. The magnitude and frequency of these artifacts significantly increases when data collection is moved from the clinic into the home. Signal processing advances have brought about significant improvement in artifact removal over the past few years. This paper reviews the physiological signals most likely to be recorded in the home, documenting the artifacts which occur most frequently and which have the largest degrading effect. A detailed analysis of current artifact removal techniques will then be presented. An evaluation of the advantages and disadvantages of each of the proposed artifact detection and removal techniques, with particular application to the personal healthcare domain, is provided.

23 July 2004 in Physiological Measurement
Verified
Journal Article
Closed access
SCShirley Coyle
Shirley Coyle
TWTomas Ward
Tomas Ward
CMCharles Markham
Charles Markham
GMGary McDarby
Gary McDarby
A brain-computer interface (BCI) gives those suffering from neuromuscular impairments a means to interact and communicate with their surrounding environment. A BCI translates physiological signals, typically electrical, detected from the brain to control an output device. A significant problem with current BCIs is the lengthy training periods involved for proficient usage, which can often lead to frustration and anxiety on the part of the user. Ultimately this can lead to abandonment of the device. The primary reason for this is that relatively indirect measures of cognitive function, as can be gleaned from the electroencephalogram (EEG), are harnessed. A more suitable and usable interface would need to measure cognitive function more directly. In order to do this, new measurement modalities, signal acquisition and processing, and translation algorithms need to be addressed. In this paper, we propose a novel approach, using non-invasive near-infrared imaging technology to develop a user-friendly optical BCI. As an alternative to the traditional EEG-based devices, we have used practical non-invasive optical techniques to detect characteristic haemodynamic responses due to motor imagery and consequently created an accessible BCI that is simple to attach and requires little user training.

18 October 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KSKevin T. Sweeney
Kevin T. Sweeney
SMSean McLoone
Sean McLoone
TWTomas Ward
Tomas Ward
Biosignal measurement and processing is increasingly being deployed in ambulatory situations particularly in connected health applications. Such an environment dramatically increases the likelihood of artifacts which can occlude features of interest and reduce the quality of information available in the signal. If multichannel recordings are available for a given signal source, then there are currently a considerable range of methods which can suppress or in some cases remove the distorting effect of such artifacts. There are, however, considerably fewer techniques available if only a single-channel measurement is available and yet single-channel measurements are important where minimal instrumentation complexity is required. This paper describes a novel artifact removal technique for use in such a context. The technique known as ensemble empirical mode decomposition with canonical correlation analysis (EEMD-CCA) is capable of operating on single-channel measurements. The EEMD technique is first used to decompose the single-channel signal into a multidimensional signal. The CCA technique is then employed to isolate the artifact components from the underlying signal using second-order statistics. The new technique is tested against the currently available wavelet denoising and EEMD-ICA techniques using both electroencephalography and functional near-infrared spectroscopy data and is shown to produce significantly improved results.

1 April 2007 in Review of Scientific Instruments
Verified
Journal Article
Closed access
KHKenneth Humphreys
Kenneth Humphreys
TWTomas Ward
Tomas Ward
CMCharles Markham
Charles Markham
We present a camera-based device capable of capturing two photoplethysmographic (PPG) signals at two different wavelengths simultaneously, in a remote noncontact manner. The system comprises a complementary metal-oxide semiconductor camera and dual wavelength array of light emitting diodes (760 and 880nm). By alternately illuminating a region of tissue with each wavelength of light, and detecting the backscattered photons with the camera at a rate of 16frames∕wavelengths, two multiplexed PPG wave forms are simultaneously captured. This process is the basis of pulse oximetry, and we describe how, with the inclusion of a calibration procedure, this system could be used as a noncontact pulse oximeter to measure arterial oxygen saturation (SpO2) remotely. Results from an experiment on ten subjects, exhibiting normal SpO2 readings, that demonstrate the instrument’s ability to capture signals from a range of subjects under realistic lighting and environmental conditions are presented. We compare the signals captured by the noncontact system to a conventional PPG signal captured concurrently from a finger, and show by means of a J. Bland and D. Altman [Lancet 327, 307 (1986); Statistician 32, 307 (1983)] test, the noncontact device to be comparable to a contact device as a monitor of heart rate. We highlight some considerations that should be made when using camera-based “integrative” sampling methods and demonstrate through simulation, the suitability of the captured PPG signals for application of existing pulse oximetry calibration procedures.