Ali M. M. Ashour

Dr. Ali M. M. Ashour

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2025 in Heat Transfer
Verified
Journal Article
Closed access
Farhan LaftaFarhan Lafta
Farhan Lafta
Mudhar A. Al-ObaidiMudhar A. Al-Obaidi
Mudhar A. Al-Obaidi
NMNajah M. L. Al Maimuri
Najah M. L. Al Maimuri
Saif Ali KadhimSaif Ali Kadhim
Saif Ali Kadhim
SAShabbir Ahmad
Shabbir Ahmad
ABAbdallah Bouabidi
Abdallah Bouabidi

9 October 2025 in International Journal of Air-Conditioning and Refrigeration
Verified
Journal Article
Open access
PDF file
AAAli M. M. Ashour
Ali M. M. Ashour
HAHayder Mohsin Ali
Hayder Mohsin Ali
Saif Ali KadhimSaif Ali Kadhim
Saif Ali Kadhim
KHKarrar A. Hammoodi
Karrar A. Hammoodi
Farhan LaftaFarhan Lafta
Farhan Lafta
ABAbdallah Bouabidi
Abdallah Bouabidi
The sustainability concern of high Global Warming Potential (GWP) refrigerants like R410A has spurred universal efforts in searching for low-GWP replacements in vapor-compression air conditioning systems. This study undertakes a comprehensive energy, exergy, and environmental analysis of five low-GWP refrigerants R32, R290, R454B, R454C, and R513A to be used as alternatives to R410A. A model of a single-stage vapor compression cycle was constructed and simulated with Engineering Equation Solver (EES) with real fluid property data under steady-state conditions. Simulation was undertaken using evaporating temperatures of –5 °C to 5 °C and condensing temperatures of 30 °C to 50 °C with fixed subcooling (5 K) and superheat (7 K) values. To maintain accuracy and credibility, the model was checked against literature data of experiments under similar working conditions with deviation of less than 10% in mass flow rate, discharge temperature, cooling capacity, power to compressor, and Coefficient of Performance (COP). From the analysis, it is found that R290 has the best thermodynamic performance with an optimal COP value of 7.91, 5.6% better than R410A and an optimal cooling capacity of 4.30 kW, 19.3% greater than R410A. It achieves the highest exergy efficiency of 0.52 and the lowest exergy destruction in components. R454B, with slightly lower COP performance, has the lowest Total Equivalent Warming Impact (TEWI) of 13.3 tons CO₂, which is some 16% less than R410A. On the other hand, R454C has the highest exergy destruction of 120.4 W and TEWI of 18.4 tons CO₂. R290 and R454B are thus found to be the best low-GWP options to fulfill the transition to environment-friendly and energy-efficient air conditioning systems.

15 July 2025 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
AAAli M. M. Ashour
Ali M. M. Ashour
Saif Ali KadhimSaif Ali Kadhim
Saif Ali Kadhim
MAMoafaq K.S. Al-Ghezi
Moafaq K.S. Al-Ghezi
Issa OmleIssa Omle
Issa Omle
Ravishankar SathyamurthyRavishankar Sathyamurthy
Ravishankar Sathyamurthy

9 October 2025 in Energy Conversion and Management
Verified
Journal Article
Closed access
AAAli M. M. Ashour
Ali M. M. Ashour
Ayad M. Al JuboriAyad M. Al Jubori
Ayad M. Al Jubori
Adrián Mota-BabiloniAdrián Mota-Babiloni
Adrián Mota-Babiloni
HAHayder Mohsin Ali
Hayder Mohsin Ali
HJHamzah M. Jaffar
Hamzah M. Jaffar
ABAbdallah Bouabidi
Abdallah Bouabidi

2 September 2025 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
Saif Ali KadhimSaif Ali Kadhim
Saif Ali Kadhim
WAWalaa Nasser Abbas
Walaa Nasser Abbas
KHKarrar A. Hammoodi
Karrar A. Hammoodi
AAAli M. M. Ashour
Ali M. M. Ashour
ABAbdallah Bouabidi
Abdallah Bouabidi
Farhan LaftaFarhan Lafta
Farhan Lafta

12 February 2026 in Water Conservation Science and Engineering
Verified
Journal Article
Closed access
PDF file
Saif Ali KadhimSaif Ali Kadhim
Saif Ali Kadhim
AAAli M. M. Ashour
Ali M. M. Ashour
ABAbdallah Bouabidi
Abdallah Bouabidi
HHHusam Abdulrasool Hasan
Husam Abdulrasool Hasan
Farhan LaftaFarhan Lafta
Farhan Lafta
KHKarrar A. Hammoodi
Karrar A. Hammoodi