Objectives To investigate the serum IL-6 levels and their rate of change in predicting the mortality of critically ill patients with COVID-19 in Vietnam. Design A single-centre, cross-sectional study. Setting An Intensive Care Centre for the Treatment of Critically Ill Patients with COVID-19 in Ho Chi Minh City, Vietnam. Participants We included patients aged 18 years or older who were critically ill with COVID-19 and presented to the study centre from 30 July 2021 to 15 October 2021. We excluded patients who did not have serum IL-6 measurements between admission and the end of the first day. Primary outcome measures The primary outcome was hospital all-cause mortality. Results Of 90 patients, 41.1% were men, the median age was 60.5 years (Q1–Q3: 52.0–71.0), and 76.7% of patients died in the hospital. Elevated IL-6 levels were observed on admission (41.79 pg/mL; Q1–Q3: 20.68–106.27) and on the third day after admission (72.00 pg/mL; Q1–Q3: 26.98–186.50), along with a significant rate of change in IL-6 during that period (839.5%; SD: 2753.2). While admission IL-6 level (areas under the receiver operator characteristic curve (AUROC): 0.610 (95% CI: 0.459 to 0.761); cut-off value ≥15.8 pg/mL) and rate of change in IL-6 on the third day of admission (AUROC: 0.586 (95% CI: 0.420 to 0.751); cut-off value ≥−58.7%) demonstrated poor discriminatory ability in predicting hospital mortality, the third day IL-6 rate of change from admission ≥−58.7% (adjusted OR: 12.812; 95% CI: 2.104 to 78.005) emerged as an independent predictor of hospital mortality. Conclusions This study focused on a highly selected cohort of critically ill COVID-19 patients with a high IL-6 level and mortality rate. Despite the poor discriminatory value of admission IL-6 levels, the rate of change in IL-6 proved valuable in predicting mortality. To identify critically ill COVID-19 patients with the highest risk for mortality, monitoring the serial serum IL-6 measurements and observing the rate of change in serum IL-6 levels over time are needed.
Evaluating the prognosis of ARDS patients using grading systems can enhance treatment decisions. This retrospective observational study evaluated the predictive accuracy of the SOFA score, APACHE II score, SpO2/FiO2 ratio, and PaO2/FiO2 ratio for mortality in ARDS patients in Vietnam. The study included 335 adult ARDS patients admitted to a central hospital from August 2015 to August 2023. Among them, 66.9% were male, the median age was 55 years, and 61.5% died in the hospital. The SOFA (AUROC: 0.651) and APACHE II scores (AUROC: 0.693) showed poor discriminatory ability for hospital mortality. The SpO2/FiO2 (AUROC: 0.595) and PaO2/FiO2 ratios (AUROC: 0.595) also displayed poor discriminatory ability. In multivariable analyses, after adjusting for the same set of confounding variables, the APACHE II score (adjusted OR: 1.152), SpO2/FiO2 ratio (adjusted OR: 0.985), and PaO2/FiO2 ratio (adjusted OR: 0.989) were independently associated with hospital mortality. Although the SOFA score (adjusted OR: 1.132) indicated a potential association with hospital mortality, it did not reach statistical significance (p = 0.081). However, a SOFA score of ≥ 10 emerged as an independent predictor (adjusted OR: 3.398) of hospital mortality. These findings emphasize the need for further studies to develop more accurate scoring systems for predicting outcomes in ARDS patients.
Background: Achieving safe and effective closure of large-bore femoral arterial access after venoarterial extracorporeal membrane oxygenation (VA-ECMO) decannulation remains challenging. Percutaneous closure with suture-mediated devices is an established alternative to surgical repair for VA-ECMO decannulation. However, the optimal suture configuration is not well defined, and conventional cross-suture placement may have limitations. This study describes a parallel percutaneous closure technique with the potential to improve outcomes and evaluates its initial feasibility and safety.Methods: This prospective case series included 30 adult patients who underwent bedside decannulation from percutaneous femoral VA-ECMO between March 2024 and March 2025. The closure technique involved deploying two Perclose ProGlide devices (Abbott Vascular) in a parallel configuration. The primary endpoints of technical success and vascular complications were assessed clinically and by duplex Doppler ultrasound 24 hours post-procedure.Results: Technical success was achieved in all 30 patients (100%) without surgical conversion or adjunctive vascular intervention. Duplex ultrasound confirmed normal arterial flow in 23 patients (76.7%). Vascular complications included arterial thrombosis (16.7%), dissection (3.3%), and hematoma (3.3%). No patient required reintervention or developed limb ischemia within 24 hours.Conclusions: This preliminary case series suggests that the parallel percutaneous closure technique is feasible and potentially safe for large-bore femoral decannulation following VA-ECMO. Its bedside application under local anesthesia and low rate of early complications support its utility in critical care. Further studies comparing closure configurations and evaluating long-term outcomes are warranted.