Richard Bailey

Dr. Richard Bailey

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in Surface and Coatings Technology
Verified
Journal Article
Closed access
Yong SunYong Sun
Yong Sun
RBRichard Bailey
Richard Bailey


4 December 2014 in Surface and Coatings Technology
Verified
Journal Article
Closed access
RBRichard Bailey
Richard Bailey
YSY. Sun
Y. Sun

21 February 2015 in Journal of Materials Engineering and Performance
Verified
Journal Article
Closed access
PDF file
RBRichard Bailey
Richard Bailey
YSY. Sun
Y. Sun

23 November 2020 in Lubricants
Verified
Journal Article
Open access
PDF file
Yong SunYong Sun
Yong Sun
RBRichard Bailey
Richard Bailey
Most of the reported work on the effect of applied potential on tribocorrosion or corrosive wear of metallic alloys in a corrosive environment were conducted at anodic potentials. Limited tests have been conducted at cathodic potentials for comparison purposes or to derive the pure mechanical wear component in tribocorrosion. This work investigated the effect of cathodic potential on the friction and wear behaviour of an important biomedical alloy, CoCrMo, sliding against an Al2O3 slider in 0.9% NaCl solution at 37 °C. High friction was found at cathodic potentials close to the open circuit potential, where mechanical wear played a predominant role in material removal. At potentials more cathodic than the hydrogen charging potential, low friction and low wear were observed. The coefficient of friction (COF) and total material loss decreased with increasing cathodic potential, such that at −1000 mV (saturated calomel electrode, SCE), extremely low COF values, as low as 0.02, and negligible material loss were obtained. Such reductions in friction and wear at increasing cathodic potentials were accompanied with the formation of parallel lines in the sliding track and were gradually diminished with increasing applied contact load. It is believed that hydrogen charging and hydrogen segregated layer formation at the surface are responsible for such a phenomenon. It can also be concluded that it is difficult to derive the pure mechanical wear component in tribocorrosion by simply conducting a test at an arbitrary cathodic potential.

25 September 2018 in Lubricants
Verified
Journal Article
Open access
PDF file
RBRichard Bailey
Richard Bailey
Titanium use is limited due to its poor tribological properties, and thermal oxidation (TO) and pack carburisation with limited oxygen diffusion (PCOD) are just two of the surface treatments that can be used to enhance the surface properties of Ti. In this study, commercially pure titanium was surface modified using thermal oxidation (TO) and pack carburisation with limited oxygen diffusion (PCOD). Samples were tribological tested in a 0.9% NaCl solution under a contact load of 20 N to investigate the mechanical and electrochemical response of the surface treatments. The tests conducted show that a clear benefit can be obtained in terms of the overall material loss rate using both TO and PCOD. The TO and PCOD treatments generate very different surface structures: TO produces a rutile TiO2 surface film and the PCOD treatment produces a TiC network structure. Both treatments improve the load bearing capacity with the assistance of an oxygen diffusion zone (ODZ). When subjected to sliding contact in a 0.9% NaCl solution, the results show the PCOD-Ti produced the best overall results, with a material loss rate 7.5 times lower than untreated Ti and 2.4 times lower than TO-Ti. The improved wear rate of the PCOD-Ti is attributed to the TiC network structure. The TO-Ti suffers from rapid film failure and high friction. The reduced material loss rate (MLR) of the TO-Ti is attributed to the hard wearing ODZ.