Dan Chen

Dan Chen


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2026 in Frontiers in Neurology
Verified
Journal Article
Open access
PDF file
XWXin Wang
Xin Wang
DCDan Chen
Dan Chen
KCKavimbi Chipusu
Kavimbi Chipusu
MAMuhammad Awais Ashraf
Muhammad Awais Ashraf
PJPeng Ji
Peng Ji
Background: Intracranial aneurysm (IA) is a focal cerebral artery dilatation affecting 2–5% of the population, with rupture leading to high mortality and disability. Early, accurate classification from computed tomography angiography (CTA) is crucial for management but is challenged by small datasets and limited interpretability. We evaluate a hybrid deep transfer learning framework with integrated Grad-CAM to improve both discrimination and explainability in CTA-based IA classification. Methods: In this retrospective study, 83 eligible patients from two centers underwent CTA. We employed stratified 5-fold cross-validation to compare: a baseline deep learning model (DL), a transfer learning-enhanced model (DL + TL), and radiologist assessment. Both AI models used a hybrid ResNet-18 architecture with LASSO feature selection and logistic regression. Performance was assessed using AUC, accuracy, calibration, decision curve analysis, NRI, and IDI. Interpretability was quantified via Grad-CAM using Intersection-over-Union (IoU) and Dice similarity coefficient. Results: The DL + TL model achieved superior performance with a mean AUC of 0.853 (95% CI: 0.789–0.912) and accuracy of 84.0%, outperforming both DL (AUC: 0.744, p = 0.012) and radiologists (AUC: 0.731, p = 0.008). Grad-CAM analysis showed DL + TL had significantly higher attention precision (IoU: 0.68 vs. 0.45 for DL, p < 0.001) and was rated more clinically relevant by blinded radiologists (4.2/5 vs. 2.8/5). Conclusion: Integrating transfer learning with quantitative interpretability assessment improves both accuracy and transparency of IA classification in limited-data settings. This framework offers a validated, interpretable approach for neurovascular imaging, pending further multi-center validation.

12 March 2026 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Open access
PDF file
WLWeiwei Lu
Weiwei Lu
FWFeng Wang
Feng Wang
LLLi Li
Li Li
DCDan Chen
Dan Chen
PJPeng Ji
Peng Ji
Objectives: Hypertensive intracerebral hemorrhage (HICH) is a frequently encountered and highly lethal cerebrovascular disorder, and postoperative rebleeding remains one of its most feared complications. Methods: We developed a nomogram featuring a hybrid architecture that integrates radiomics-derived signatures and deep learning representations from CT imaging together with routine clinical parameters, with the goal of enhancing the individualized prediction of rebleeding risk following surgical intervention in HICH patients. A total of 151 individuals diagnosed with HICH were prospectively enrolled and randomly assigned to a training set (n=105) and a validation set (n=46) following a 7:3 ratio. Results: The resulting model outperformed single-domain approaches relying solely on traditional clinical indicators or deep learning features. In the training cohort, the nomogram yielded an AUC of 0.993 (95 % CI: 0.982–1.000), while in the internal testing cohort, the AUC reached 0.860 (95 % CI: 0.745–0.974). The model highlighted several key predictors associated with postoperative rebleeding. Conclusions: Overall, the integrated nomogram, embedding clinical data, radiomic phenotypes, and deep learning markers, exhibited robust predictive capability in assessing rebleeding risk among patients with HICH. Ongoing research is needed to further refine and validate the model in broader clinical settings.