Ye Seul Jung

Ms. Ye Seul Jung


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
JLJung-Tae Lee
Jung-Tae Lee
DLdajung Lee
dajung Lee
YJYe Seul Jung
Ye Seul Jung
SLSung-Ho LEE
Sung-Ho LEE
SKSungtae Kim
Sungtae Kim
Dong-Wook HanDong-Wook Han
Dong-Wook Han
Background: Three-dimensional (3D) printed scaffolds have emerged as promising tools for bone regeneration, but the optimal structural design and pore size remain unclear. Polylactic acid (PLA) reinforced with graphene oxide (GO) offers enhanced mechanical and biological performance, yet systematic evaluation of architecture and pore size is limited. Methods: Two scaffold architectures (lattice-type and dode-type) with multiple pore sizes were fabricated using UV-curable PLA/GO resin. Physical accuracy, porosity, and mechanical properties were assessed through compression and fatigue testing. Based on in vitro screening, four pore sizes (930 μm, 690 μm, 558 μm, 562 μm) within the dode-type structure were analyzed. The 558 μm and 562 μm scaffolds, showing distinct fracture thresholds, were further evaluated in rat and rabbit calvarial defect models for inflammation and bone regeneration. Results: In vitro testing revealed that while 930 μm and 690 μm scaffolds exhibited superior compressive strength, the 562 μm scaffold showed a unique critical fracture behavior, and the 558 μm scaffold offered comparable stability with higher resistance to premature failure. In vivo studies confirmed excellent biocompatibility in both groups, with early bone formation favored in the 558 μm scaffold and more continuous and mature bone observed in the 562 μm scaffold at later stages. Conclusions: This stepwise strategy—from structural design to pore size screening and preclinical validation—demonstrates that threshold-level mechanical properties can influence osteogenesis. PLA/GO scaffolds optimized at 558 μm and 562 μm provide a translationally relevant balance between mechanical stability and biological performance for bone tissue engineering.

19 June 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
NSNa Ri Seo
Na Ri Seo
YJYe Seul Jung
Ye Seul Jung
DPDayeon Park
Dayeon Park
JKJisung Kim
Jisung Kim
Dong-Wook HanDong-Wook Han
Dong-Wook Han
Bongju KIMBongju KIM
Bongju KIM
Objective: This in vitro study evaluated the insertion torque characteristics of the KS 3 implant compared with the TSIII implant in standardized artificial bone models representing weak bone, extraction-socket-like reduced support, and maxillary sinus simulation conditions. Materials and Methods: A comparative in vitro study was performed using three models: a weak bone model, a standardized extraction-socket-like reduced-support model, and a maxillary sinus simulation model. Maximum and final insertion torque values were obtained from torque–depth curves. Torque–depth integrals were additionally calculated as exploratory secondary parameters. Statistical analyses were performed using Welch’s t-test and two-way ANOVA where appropriate, and the results were interpreted as exploratory because of the limited sample size. Results: The KS 3 implant showed higher maximum and/or final insertion torque values than the TSIII implant in the weak bone, extraction-socket-like, and maxillary sinus simulation models. In the maxillary sinus model, the torque values showed directional differences according to implant type and residual bone height under the tested fixed undersized drilling protocols for both CAS drilling and bone compaction drilling. Torque–depth integral analysis provided additional information regarding cumulative insertion resistance. Conclusions: Within the limitations of this controlled in vitro study, the KS 3 implant showed higher insertion torque values than the TSIII implant under the tested artificial bone conditions. These findings should be interpreted as in vitro insertion torque data under the tested artificial bone and drilling conditions, not as evidence of clinical superiority. In the maxillary sinus simulation model, the observed torque differences should be interpreted as the combined effect of implant macrodesign and the fixed undersized drilling protocol, rather than as an isolated macrodesign effect.