Marwan AL AKKAD

Dr. Marwan AL AKKAD

Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacký University, Olomouc, Olomoucký Kraj, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2022 in PeerJ
Verified
Journal Article
Open access
PDF file
RMRadek Mounajjed
Radek Mounajjed
TTThomas Taylor
Thomas Taylor
OHOmar Hamadah
Omar Hamadah
IVIva Voborná
Iva Voborná
Marwan AL AKKADMarwan AL AKKAD
Marwan AL AKKAD
Background: The master cast is the gold standard for the control and eventual adjustment of restorations produced by conventional procedures. Some digital workflow bypasses the master cast and relies completely on the precision of the CAD/CAM restoration. Aim: To examine the reproducibility of the margins of CAD/CAM restorations generated from a single digital scan. Also, to check the readiness of these restorations for delivery directly after fabrication without adjustment on a master cast and thereby eliminate the need for the master cast. Methods: A total of 18 metal substructures made from cobalt chrome alloy were fabricated utilizing a single STL file. The circumference was divided into eight zones. The vertical marginal discrepancy (VMD) was measured at each zone of each metal substructure, with optical microscopy at ×200 magnification. Results: Measurements of vertical marginal discrepancy were in a range of (−94: 300) with a mean of 62 ± 60 μm. A one-way ANOVA test revealed that the mean VMD is significantly different among the 18 substructures (F17, 1,134 = 63.948, p < 0.001). Conclusion: Although all the received substructures were fabricated from the same scan file, they were not identical and varied widely, and they were going outside the acceptable range in some zones. Within the limitations of this study, the marginal fit can be improved by extraoral adjustments on the master cast. Thus, skipping the master cast deprives the dentist of delivering a restoration of higher quality.

26 May 2026 in Acta Medica (Hradec Kralove, Czech Republic)
Verified
Journal Article
Open access
SASamer Al Akkad
Samer Al Akkad
Mohammad Younis HajeerMohammad Younis Hajeer
Mohammad Younis Hajeer
Marwan AL AKKADMarwan AL AKKAD
Marwan AL AKKAD
Background: Otologic symptoms are commonly reported by patients with temporomandibular disorders. Objective: This study aims to investigate the likely outcome or progression of temporomandibular disorders with and without accompanying otologic symptoms when treated in the dental clinic. Methods: The study is registered under the International Standard Randomised Controlled Trial Number: ISRCTN49976724, DOI: 10.1186/ISRCTN49976724. Forty patients with temporomandibular disorders were included and allocated into two groups: Control group (n=20): isolated temporomandibular disorders symptoms, and Experimental group (n=20): temporomandibular disorders symptoms with otologic symptoms (confirmed by otorhinolaryngological evaluation to exclude primary ear pathology). All participants underwent non-invasive, non-pharmacological treatment. The treatment contained physiotherapy and custom-made occlusal splints. Outcomes (full/partial/no recovery) were assessed at 3 months by a single maxillofacial surgeon, with follow-up every 3 weeks. Statistical analysis included Fisher’s exact test and odds ratios. Results: Fisher’s exact test revealed a statistically significant association between group allocation and recovery outcomes (χ 2 =5.979, p=0.041). The odds ratio was 5.33. Conclusion: The presence of otological symptoms accompanying temporomandibular disorders might predict a better prognosis after non-invasive, non-pharmacological treatment, perhaps not as a direct predictor per se but as a confounding factor.

17 April 2025 in Journal of Prosthodontics
Verified
Journal Article
Open access
Marwan AL AKKADMarwan AL AKKAD
Marwan AL AKKAD
JSJohn Sorensen
John Sorensen
OHOmar Hamadah
Omar Hamadah
IVIva Voborná
Iva Voborná
MMMarek Matoušek
Marek Matoušek
RMRadek Mounajjed
Radek Mounajjed
Purpose: This study evaluated and compared the marginal fidelity of milled zirconia copings before and after finishing and polishing with and without a control die.Materials and Methods: This prospective multicenter in vitro trial involved two methods regularly used in two clinics for hybrid and full‐digital workflows. A typodont mandibular molar was prepared. From each workflow, 20 zirconia crown copings were milled from a single scan. Ten zirconia crown copings were assigned randomly from each workflow to be finished and polished. Finishing and polishing in the hybrid workflow were done directly on the typodont, representing the control die. There were four groups in this study: No‐die‐Before (full‐digital without finishing and polishing), No‐die‐After (hybrid without finishing and polishing), Die‐based‐Before (full‐digital with finishing and polishing), and Die‐based‐After (hybrid with finishing and polishing). The typodont tooth was divided into eight zones for systematic measurement. All groups were evaluated using a digital optical microscope.Results: The mean values with the standard deviation of No‐die‐Before, No‐die‐After, Die‐based‐Before, and Die‐based‐After groups were 24.90 ± 23.88, 30.62 ± 32.63, 21.03 ± 16.65, and 18.93 ± 18.27, respectively. The maximum values for the No‐die‐Before and No‐die‐After groups were 124 and 131 µm, respectively. All the values in the Die‐based‐Before and Die‐based‐After groups were less than the acceptable marginal gap of 75 µm.Conclusions: There was no statistical significance between the two workflows. However, the control die enabled achieving superior accuracy. Without it, the marginal gap might worsen after finishing and polishing in the full‐digital workflow.


9 July 2026 in Journal of Prosthodontics
Verified
Journal Article
Open access
PDF file
Marwan AL AKKADMarwan AL AKKAD
Marwan AL AKKAD
BYBedirhan Savas Yigit
Bedirhan Savas Yigit
IVIva Voborná
Iva Voborná
VPVaclav Prokupek
Vaclav Prokupek
OFOluwafunmibi Fasanya
Oluwafunmibi Fasanya
RMRadek Mounajjed
Radek Mounajjed
Purpose: This study evaluated and compared the marginal fit of CAD–CAM zirconia crown copings with and without a 3D‐printed control model. Materials and Methods: This prospective in vitro trial involved 30 zirconia crown copings made from the same STL file. These were divided into two groups. Half of them had their own 3D‐printed control model made from the same STL file (With‐Printed‐Model group), whereas the other half lacked any control model (No‐Printed‐Model group). Both groups underwent manual adjustments in a systematic way. Their marginal gaps were evaluated using a digital optical microscope from eight zones: buccal, mesiobuccal, mesial, mesiopalatal, palatal, distopalatal, distal, and distobuccal. Results: The mean values with standard deviations for the With‐Printed‐Model and No‐Printed‐Model groups were 15.18 ± 14.49 and 12.46 ± 14.09 µm, respectively. All crown copings from both groups were below 75 µm. Statistical analysis showed a significant difference between the two groups. Conclusion: The No‐Printed‐Model group demonstrated superior marginal fit compared to the With‐Printed‐Model group. However, the largest marginal gaps from each group were still within the clinically acceptable range below 75 µm. Although the 3D‐printed control model did not improve marginal fit, its primary function is to effectively identify major manufacturing errors.

15 December 2021 in Stomatológ
Verified
Journal Article
Open access
PDF file
SASami Albatal
Sami Albatal
CKChaza Kouchaji
Chaza Kouchaji
Marwan AL AKKADMarwan AL AKKAD
Marwan AL AKKAD
RMRadek Mounajjed
Radek Mounajjed
Tento ?l?nok opisuje vykon?vanie pulpot?mie u die?a?a s pou?it?m portlandsk?ho cementu v trvalom mol?ri s uzavret?mi apexami a ireverzibilnou pulpit?dou. 9-ro?n? pacient sa 4 - 5 dn? s?a?oval na boles? v oblasti prav?ho zadn?ho zuba. Po komple...