Lorenzo TESTAVERDE

Dr. Lorenzo TESTAVERDE

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2011 in European Journal of Radiology
Verified
Journal Article
Closed access
LTLorenzo TESTAVERDE
Lorenzo TESTAVERDE
APAnna Perrone
Anna Perrone
LCLaura Caporali
Laura Caporali
AEAntonella Ermini
Antonella Ermini
LILuciano Izzo
Luciano Izzo
MMMario Marini
Mario Marini

9 December 2011 in European Radiology
Verified
Journal Article
Closed access
PDF file
LTLorenzo TESTAVERDE
Lorenzo TESTAVERDE
LCLaura Caporali
Laura Caporali
EVEugenio Venditti
Eugenio Venditti
GGGiovanni Grillea
Giovanni Grillea
CCClaudio Colonnese
Claudio Colonnese

6 December 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
Irene GrazziniIrene Grazzini
Irene Grazzini
DRDavide Del Roscio
Davide Del Roscio
MCMarco Cirinei
Marco Cirinei
BCBenedetta Calchetti
Benedetta Calchetti
MGMatteo Grammatico
Matteo Grammatico
LTLorenzo TESTAVERDE
Lorenzo TESTAVERDE
Background/Objectives: The aim of the study was to compare diagnostic performance of 3D-Double Inversion Recovery (DIR) and 3D-Fluid-Attenuated Inversion Recovery (FLAIR) sequences in the detection of brain lesions in Multiple Sclerosis (MS) patients, especially cortical ones, and to evaluate potential correlation between lesion number and clinical outcome. Methods: From April 2021 to July 2024, 278 MS patients (201 females, 77 males, mean age 47.01 ± 12.668 years) underwent brain MRI in three Italian Institutions using 1.5 T systems; 3D-FLAIR and 3D-DIR sequences were obtained with an identical anatomic position. Clinical disability was evaluated by the expanded disability state score (EDSS). Data analysis was performed using the Wilcoxon test for lesion count differences (primary endpoint), and Chi-square test and Spearman for EDSS correlation (secondary endpoint); a p < 0.05 was considered as statistically significant. Results: A significantly higher total number of lesions was displayed on DIR images (n = 6601) compared with FLAIR (n = 6484) (p < 0.001). The mean number of cortical lesions identified with DIR (1.56 ± 2.767) was significantly higher than the mean number of cortical lesions detected with FLAIR (0.52 ± 1.029) (p < 0.001). Conversely, FLAIR sequences detected a significantly higher mean number of subcortical lesions (9.34 ± 8.663) compared to DIR (8.94 ± 8.415) (p < 0.001). A significant correlation was found between EDSS and the number of juxtacortical and cortical lesions detected with DIR with a p < 0.001. Conclusions: 3D-DIR is superior to 3D-FLAIR in detecting cortical lesions, which are correlated to clinical disability, and it should be implemented for the diagnosis and prognostic evaluation in MS patients.