Zi-Meng Xiao

Ms. Zi-Meng Xiao


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2025 in Metals
Verified
Journal Article
Open access
PDF file
ZXZi-Meng Xiao
Zi-Meng Xiao
HZHuiling Zhou
Huiling Zhou
SLSheng Lu
Sheng Lu
ZWZe-Xin Wang
Ze-Xin Wang
DODubovy Oleksandr
Dubovy Oleksandr
TA2 titanium was brazed with a Ti–37.5Zr–15Cu–10Ni filler metal at 860–890 °C for 20 min to investigate the influence of temperature on joint properties. Raising the brazing temperature reduced residual filler in the seam center and transformed the microstructure from heterogeneous phases to a uniform α-(Ti,Zr) solid-solution matrix, accompanied by significant widening of the diffusion layer. At brazing temperatures of 890 °C, the hardness decreased to below 300 HV0.5 and became more uniform as brittle phases were suppressed. The shear strength reached a maximum of 302 MPa, and the fracture morphology exhibited characteristics of ductile fracture. Micro-electrochemical testing indicated that the joint brazed exhibited an almost uniform current distribution and significantly reduced localized corrosion. Although a small fraction of the Widmanstätten structure was observed at this temperature, it did not impair the overall mechanical performance. These findings demonstrate that a moderate increase in brazing temperature promotes elemental diffusion, alleviates brittle phase enrichment, and markedly enhances the mechanical properties and corrosion resistance of TA2 joints.

20 November 2025 in Coatings
Verified
Journal Article
Open access
PDF file
WLWei-Gang Lv
Wei-Gang Lv
ZWZe-Xin Wang
Ze-Xin Wang
ZXZi-Meng Xiao
Zi-Meng Xiao
SZShu-Fan Zhou
Shu-Fan Zhou
JMJun Ma
Jun Ma
DODubovy Oleksandr
Dubovy Oleksandr
This study investigates the influence of Ag addition on the microstructure, mechanical behavior, corrosion resistance, and antibacterial performance of Mg-Zn-Ca-Ag alloys and their micro-arc oxidation (MAO) coatings. Four casting alloys containing 0.2, 0.4, 0,6 and 0.8 wt.% Ag were fabricated and characterized by SEM, XRD, and TEM. The microstructure consisted mainly of α-Mg, Mg2Ca, Mg7Zn3, and Mg6Ca2Zn3 phases, and the elastic modulus (~25.8 GPa) was comparable to that of human bone. MAO coatings produced in a bio-functional electrolyte exhibited pit-like morphologies due to Ag-induced melt fluidity and self-sealing effects. The coatings were composed primarily of MgO, Mg2SiO4, Ca3(PO4)2, CaCO3, and Ag2O, with the ZQ 0.8-MAO sample showing the highest Ca/P ratio (1.75), indicative of superior bioactivity. Electrochemical impedance spectroscopy revealed optimal corrosion resistance (2.56 × 104 Ω·cm2), while antibacterial efficiency exceeded 96%. Overall, Ag alloying enhanced both the bulk and surface properties of Mg-Zn-Ca alloys, yielding robust, corrosion-resistant, and antibacterial coatings with excellent biocompatibility-highlighting their potential for biodegradable orthopedic implant applications.

22 November 2025 in Coatings
Verified
Journal Article
Open access
PDF file
WLWeigang Lv
Weigang Lv
ZWZe-Xin Wang
Ze-Xin Wang
ZXZi-Meng Xiao
Zi-Meng Xiao
YZYouna Zhao
Youna Zhao
JMJun Ma
Jun Ma
DODubovy Oleksandr
Dubovy Oleksandr
To address the challenges of excessively fast degradation and relatively poor biocompatibility of biomedical magnesium alloys, in this study, Mg/HA magnesium alloy treated by different friction stir processing (FSP) techniques served as the substrate for fabricating a micro-arc oxidation (MAO) coating. SEM, EDS, XRD, and XPS were employed to characterize the coating’s microstructure, phase composition, and element distribution, while its comprehensive properties were evaluated via electrochemical tests, nanoindentation, friction–wear experiments, contact angle measurements, and antibacterial assays. Results indicate that MAO coatings on all substrates exhibit a dense, uniform grayish-white macroscopic morphology with 3–5 μm pores. Cross-sectional observations reveal a metallurgical bond between the coating and substrate, with minor blind pores and microcracks distributed in the coating, and different coatings show similar thickness and high density. The coatings mainly consist of Ca3(PO4)2, CaCO3, Mg, MgSiO3, and MgO. HA powder is uniformly dispersed in the substrate treated by 1500-3 FSP passes, promoting more Ca2+ and PO43− release during the MAO process. This yields the highest Ca/P ratio, endowing the coating with excellent biological performance to induce osteocyte growth. All coatings have good wear/corrosion resistance and a maximum adhesion of 14.485 N. Notably, MAO coatings on substrates with 1500-3 and 1700-3 FSP passes are moderately hydrophilic, facilitating cell adhesion/spreading and meeting biomedical implants’ short-term antibacterial rate requirements.

4 February 2026 in Metals
Verified
Journal Article
Open access
PDF file
WLWei-Gang Lv
Wei-Gang Lv
ZXZi-Meng Xiao
Zi-Meng Xiao
ZWZe-Xin Wang
Ze-Xin Wang
SLSheng Lu
Sheng Lu
DODubovy Oleksandr
Dubovy Oleksandr
Liang-Yu ChenLiang-Yu Chen
Liang-Yu Chen
Titanium alloys are widely used as bone graft materials due to their excellent corrosion resistance and biocompatibility. Implant failure can result from long-term exposure to body fluids and inflammation-induced pH decreases, both of which compromise the material’s corrosion resistance and mechanical stability. To address this issue, porous Ti-6Al-4V alloy was selected in this work. Immersion tests were conducted in Hank’s solution with different pH values (3, 5, and 7) for 90 days to simulate the in vivo microenvironment under various physiological conditions. The degradation behavior of porous Ti-6Al-4V alloy during the 90-day immersion period was systematically investigated using a combination of characterization techniques. The results indicated that TiO2, Ca3(PO4)2, and Ca(H2PO4)2 phases were formed on the surface of the after 90 days of immersion. Massive dissolution of TiO2 was observed in solutions with high H+ concentration (low pH). Ion release tests revealed that the concentration of titanium ions released was significantly higher in acidic solutions, suggesting that the passive film formed on porous Ti-6Al-4V alloy was unstable and prone to dissolution under acidic conditions. Consequently, a large amount of corrosion products accumulated on the specimen surfaces immersed in acidic solutions for a long duration. Moreover, the compression properties of the samples deteriorated after immersion. Specifically, the compressive strength decreased by 12.68 MPa, 11.67 MPa, and 5.84 MPa for sample immersed in solutions with pH = 3, 5, and 7, respectively. The significant reduction in compressive performance of the alloy in high H+ concentration solutions was attributed to the decreased compactness caused by ion release. The fracture mode of the porous Ti-6Al-4V alloy after immersion was identified as a mixed mode of ductile and brittle fracture.