Thiago Bessa Marconato Antunes

Dr. Thiago Bessa Marconato Antunes


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2022 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Open access
LPLauter Eston Pelepenko
Lauter Eston Pelepenko
MMMarina Angelica Marciano
Marina Angelica Marciano
TFTamires Melo Francati
Tamires Melo Francati
GBGabriela Bombarda
Gabriela Bombarda
TAThiago Bessa Marconato Antunes
Thiago Bessa Marconato Antunes
Josette CamilleriJosette Camilleri
Josette Camilleri
The substitution of calcium with strontium in bioactive materials has been promising but there has been some concern over the material instability and possible toxicity. The aim of this research was the synthesis and characterization of calcium and strontium substituted bioactive materials and assessment of interactions with local tissues and peripheral elemental migration in an animal model. A bioactive glass, hydroxyapatite and hydraulic calcium silicate with 50% or 100% calcium substitution with strontium were developed and the set materials were characterized immediately after setting and after 30 and 180‐days in solution. Following subcutaneous implantation, the local (tissue histology, elemental migration) and systemic effects (elemental deposition after organ digestion) were assessed. The strontium‐replaced silicate cements resulted in the synthesis of partially substituted phases and strontium leaching at all‐time points. The strontium silicate implanted in the animal model could not be retrieved in over half of the specimens showing the high rate of material digestion. Tissue histology showed that all materials caused inflammation after 30 days of implantation however this subsided and angiogenesis occurred after 180 days. Strontium was not detected in the local tissues or the peripheral organs while all calcium containing materials caused calcium deposition in the kidneys. The tricalcium silicate caused elemental migration of calcium and silicon in the local tissues shown by the elemental mapping but no deposition of calcium was identified in the peripheral organs verified by the assessment of the digested tissues. Strontium can substitute calcium in bioactive materials without adverse local or systemic effects.

3 May 2024 in Journal of Periodontal Research
Verified
Journal Article
Closed access
RLR. L. Lucateli
R. L. Lucateli
PSPedro Felix Silva
Pedro Felix Silva
SSS. L. Salvador
S. L. Salvador
Edilson ErvolinoEdilson Ervolino
Edilson Ervolino
FFFlavia Furlaneto
Flavia Furlaneto
MMMichel Reis Messora
Michel Reis Messora

1 January 2021 in Brazilian Oral Research
Verified
Journal Article
Open access
LPLauter Eston Pelepenko
Lauter Eston Pelepenko
FSFlávia Saavedra
Flávia Saavedra
TAThiago Bessa Marconato Antunes
Thiago Bessa Marconato Antunes
GBGabriela Bombarda
Gabriela Bombarda
Brenda Paula GomesBrenda Paula Gomes
Brenda Paula Gomes
Marina Angélica Marciano da SilvaMarina Angélica Marciano da Silva
Marina Angélica Marciano da Silva
This study evaluated the physicochemical, biological, and antimicrobial properties of a new hydraulic calcium silicate-based modified material, and compared it with MTA Repair HP and MTA Angelus. The materials were assessed regarding color luminosity (L), color change, radiopacity, setting time, and ISO 6876:2012 linear flow. Volumetric filling and volume change were evaluated using microcomputed-tomography (µCT). Chemical characterization after 28 days in Hank's Balanced Salt Solution (HBSS) and pH analysis were also assessed. Biological characterization of cytotoxicity and microbiological assessment were also undertaken. Shapiro-Wilk, ANOVA, Levene and post hoc analyses with Bonferroni correction were performed, adopting a 5% significance level (p <0.05). Bio-C Pulpo exhibited the highest L values after 90 days. All tested materials demonstrated color change during the analyses, and had radiopacity above 5 mm Al. MTA Repair HP set faster than Bio-C Pulpo, whereas the latter had the highest linear flow. MTA Repair HP had the highest volumetric filling in µCT analysis. Bio-C Pulpo showed the highest alkalinity during all tested periods, and the highest volumetric loss (above 9%), in comparison with MTA Repair HP and MTA Angelus. Bio-C Pulpo did not form calcium hydroxide after hydration. MTA Repair HP demonstrated the highest cytocompatibility, and Bio-C Pulpo, the highest cytotoxicity. No inhibition halos were observed for any material, and similar higher turbidity values were seen after direct contact. Composition additives used in Bio-C Pulpo modified its properties, and both the absence of calcium hydroxide deposition after hydration, and the related cytotoxicity of this material are of particular concern.

1 January 2019 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
PDF file
Rodrigo LinsRodrigo Lins
Rodrigo Lins
JCJairo Matozinho Cordeiro
Jairo Matozinho Cordeiro
CRCarolina Perez Rangel
Carolina Perez Rangel
TAThiago Bessa Marconato Antunes
Thiago Bessa Marconato Antunes
LMLuís Roberto Marcondes Martins
Luís Roberto Marcondes Martins
Lins RB, et al. Restor Dent Endod. 2019 May;44:e37. https://doi.org/10.5395/rde.2019.44.e37

1 July 2026 in Materials
Verified
Journal Article
Open access
PDF file
Marina Angélica Marciano da SilvaMarina Angélica Marciano da Silva
Marina Angélica Marciano da Silva
JPJennifer Santos Pereira
Jennifer Santos Pereira
TAThiago Bessa Marconato Antunes
Thiago Bessa Marconato Antunes
Paulo J. PalmaPaulo J. Palma
Paulo J. Palma
Nanotechnology has emerged as a promising strategy in restorative dentistry and endodontics due to the physicochemical and biological properties of nanomaterials. This narrative review aimed to critically analyze the current applications of nanomaterials in restorative dentistry and endodontics, highlighting their mechanisms of action, biological properties, and translational potential. A literature search was performed in the PubMed/MEDLINE database using combinations of MeSH terms and free keywords related to nanomaterials and dental applications. Studies published in English within the last twenty years and addressing restorative or endodontic applications were considered. After screening and eligibility assessment, 69 studies were included in the descriptive analysis. The findings indicate that nanomaterials have been investigated in preventive strategies, adhesive systems, restorative materials, intracanal medicaments, endodontic sealers, vital pulp therapy, and regenerative formulations. In restorative dentistry, nanoparticles such as silver nanoparticles, nano-hydroxyapatite, amorphous calcium phosphate, bioactive glass nanoparticles, and chitosan-based systems showed favorable antimicrobial, remineralizing, and material-enhancing properties. In endodontics, silver and chitosan nanoparticles showed potential for intracanal disinfection and biofilm disruption, while chlorhexidine, zinc, and bioactive glass nanoparticles enhanced the antimicrobial activity and sealing ability of endodontic sealers. In addition, magnetic nanoparticles, mesoporous silica nanoparticles, and hydroxyapatite nanoparticles presented promising applications in regenerative endodontics and vital pulp therapy. However, most of the available evidence is still based on in vitro studies, with limited long-term clinical validation. Overall, nanotechnology offers potential experimental advantages for improving preventive, restorative, and endodontic therapies; however, its successful clinical translation remains strictly dependent on overcoming critical biosafety barriers and addressing long-term toxicity concerns.

9 December 2025 in Australian Endodontic Journal
Verified
Journal Article
Open access
TAThiago Bessa Marconato Antunes
Thiago Bessa Marconato Antunes
AJAna Cristina Padilha Janini
Ana Cristina Padilha Janini
IHIsis Hinnebusch
Isis Hinnebusch
NSNilvan Alves da Silva
Nilvan Alves da Silva
GFGaspar Darin Filho
Gaspar Darin Filho
Marina Angélica Marciano da SilvaMarina Angélica Marciano da Silva
Marina Angélica Marciano da Silva
The objective of this study was to assess the hydration, crystalline structure, and setting of bioceramic ready‐to‐use and powder/liquid sealers in dry and wet root canal dentine. Thirty‐two single‐rooted human teeth were embedded in acrylic resin and sectioned into 2‐mm segments. Canals were filled under dry or moist conditions using BioRoot RCS or Bio‐C Sealer. Setting time was assessed using a modified Gilmore needle. Hydration was analyzed via Raman and FT‐IR spectroscopy and X‐ray diffraction (XRD) after 28 days. Data were analysed using two‐way ANOVA and Tukey test ( α = 5%). Bio‐C Sealer had shorter setting times in moist canals ( p < 0.01), while BioRoot showed no significant difference ( p > 0.05). Raman identified a calcite peak (1150 cm −1 ), and FT‐IR showed water reduction over time. XRD detected calcium hydroxide in moist Bio‐C Sealer and apatite/calcite in BioRoot. Dentine moisture is crucial for the setting of ready‐to‐use calcium silicate‐based sealers.