Mulia Orientilize

Dr. Mulia Orientilize


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2021 in Makara Journal of Technology
Verified
Journal Article
Open access
PDF file
Mulia OrientilizeMulia Orientilize
Mulia Orientilize
JRJosia Irwan Rastandi
Josia Irwan Rastandi
RCR. M. Dimas Aries C
R. M. Dimas Aries C
MPMarsha Niken P
Marsha Niken P
KSKrisna Adi S.S
Krisna Adi S.S
AAAbimantrana Abimantrana
Abimantrana Abimantrana
MJT Makara Journal of Technology

1 January 2021 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
Mulia OrientilizeMulia Orientilize
Mulia Orientilize
WPW A Prakoso
W A Prakoso
MFM Fadel
M Fadel
RFR P Fernaldy
R P Fernaldy
The amount of spiral reinforcement in the spun pile manufactured in Indonesia is below the minimum requirement. Additional shear reinforcement is needed, particularly on a pile at the adjacent pile cap. To cope with the deficiency, steel jacket is initiated to strengthen the pile. A numerical study was performed to study the effect of steel jacket addition to spun pile behavior. Two different software, SAP and Abaqus were employed. Pushover analysis was performed with a monotonic loading approach. The parameters studied were the steel jacket’s thickness and the existence of adhesive between the steel and the concrete surface. Brittle behavior was detected with the presence of steel jacket which was indicated by the force displacement curve. The steel improves the strength of the spun pile connection but decreases the ductility. It seems that pile is in over reinforced condition. To get a thorough understanding, a 3D model with Abaqus software was performed. Steel jacket is applied on the spun pile without rebar inside concrete fill and thinner steel was selected to prevent over reinforce. Hence, different results were found where spun pile connections behave in a ductile manner. Steel jacket improves not only the strength of spun pile connection but also the ductility.

14 April 2022
Verified
Conference Paper
Open access
PDF file
Mulia OrientilizeMulia Orientilize
Mulia Orientilize
PAPrakoso Widjojo Adi
Prakoso Widjojo Adi
MNMentari Nadila
Mentari Nadila
The numerical study has been conducted to investigate the behaviour of spun pile – pile cap connection based on the common practice in Indonesia. The piles manufactured in Indonesia have low confinement where the amount of transverse reinforcement is less than 20% than the minimum requirement set by ACI 318-19. The research objectives are to study the parameters that affect the behaviour of that connection. Three parameters investigated are: the connection details, the effect of concrete infill and the amount of transverse reinforcement. The typical connection of spun pile and pile cap in Indonesia is considered adequate and can perform as fixed connection since slip at connection region was not detected in the FE analysis. The embedment length is adequate to develop yield strength of the prestressed wire. By filling the hollow with the concrete it increases the connection strength by 15% whereas the strength improves more than 50% by adding 6D19 reinforced bar. Adequate confinement improves the performance of the connection at peak post-stage that affects ductility.

1 January 2021 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
Mulia OrientilizeMulia Orientilize
Mulia Orientilize
WPW A Prakoso
W A Prakoso
ASA P Swastinitya
A P Swastinitya
Numerical study to investigate the effect of various loading protocol to seismic performance of spun pile connection has been performed using OpenSees. Six loading protocols adopted in FEMA P440 were applied to three specimens. The study started with validation of FE model, and the model can closely simulate the experiment conducted by another researcher. The loading was presented in the form of a drift ratio, a number of cycles, and the rate of loading. It is found that different types of loading protocols affect seismic performance in terms of stiffness and strength degradation. Among six loading protocols, TP-01, as adopted in ACI 437.1R-07, give moderate results. Significant stiffness degradation was observed on hollow spun pile compare to those with concrete infill. It is found that the presence of concrete infill improves the strength of the spun pile connection by 45%. Increase the strength of concrete infill slightly improve the performance of spun pile.

1 January 2021 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
JRJ I Rastandi
J I Rastandi
KPK Pramesti
K Pramesti
Mulia OrientilizeMulia Orientilize
Mulia Orientilize
The dynamic test has been performed on Jembatan Teksas, Universitas Indonesia. The purpose of the test was to obtain the dynamic parameters, which are the natural frequencies, the mode shapes, and the damping ratio. The test was conducted by applied forced excitation using an eccentric mass shaker. The dynamic responses were recorded using accelerometers and vibrometer during forced vibration state and a free vibration state. A comparison study was conducted through the 3D finite element analysis using SAP2000. The test could obtain five mode shapes of the bridge and the damping ratio. Close results were found between FE analysis and the test result. The average damping ratio obtained was 1.72% which was within the range of welding steel structures according to reference. Compared to the test conducted in 2011 and 2013, the bridge is in good condition which is indicated by its natural frequency where the current test decrease less than 2%.

1 April 2020 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
ARAhmad Zaki Risadi
Ahmad Zaki Risadi
JRJosia Irwan Rastandi
Josia Irwan Rastandi
BSBastian Okto Bangkit Sentosa
Bastian Okto Bangkit Sentosa
Mulia OrientilizeMulia Orientilize
Mulia Orientilize
At present, structural assessment using dynamic characteristics remains to be explored. In this study, a correlation between damage index and natural frequencies of Concentric Braced Frame steel structures has been observed. The study consists of two sections: the first section presents the calculation of the damage indices of structures by means of monotonic and semicyclic pushover analyses using OpenSEES software, while the second section evaluates the structures’ natural frequencies by means of modal analyses using SAP2000 software. Our results show a trend in which with increasing amounts of lateral load, natural frequencies of the structures decrease while the damage indices increase. There is also an apparent ‘jump’ in the damage index values after the lateral loads reach their critical limits. The study results help the understanding of the structural assessment process at the global scale.