Introduction: Spectral detector computed tomography (SDCT), a cutting-edge technique in veterinary medicine, offers various options for characterizing soft tissues. One such option is the virtual non-contrast (VNC) algorithm, which reconstructs pre-contrast images from post-contrast spectral data by identifying and subtracting iodine pixels. This method has demonstrated accuracy in assessing abdominal organs in healthy canine patients. To determine whether this algorithm can be applied in a clinical setting to reduce radiation dose, scan time, and, consequently, the duration of general anesthesia, its accuracy in patients with pathology must be evaluated.Methods: Our study compared the Hounsfield units (HUs) measured in VNC and true unenhanced (TUE) images for splenic pathologies in general, as well as for specific types of pathologies based on their imaging characteristics. All differences were determined through subtraction and evaluated by using cut-off values of ≤ 5, ≤ 10, and ≤ 15 HUs. Differences in HUs of ≤ 10 were deemed negligible, while differences ≤ 15 HUs were considered acceptable. Two one-sided t-tests were performed. Additionally, image quality and iodine subtraction were evaluated using a five-point Likert scale.Results: For splenic pathologies in general, lesions classified by imaging characteristics and various pathologies, the VNC technique demonstrated high efficiency in contrast medium subtraction and exhibited a strong agreement with TUE images regarding their HUs. In 305 drawn regions of interest (ROIs), the differences in HUs between TUE and VNC were ≤ 15 HUs in 98.0%, ≤ 10 HUs in 93.1%, and at least 66.2% were below the limit of 5 HUs. SDCT images provided better image quality than conventional computed tomography images.Discussion: Our study suggests that VNC images reconstructed from post-contrast SDCT data may serve as a promising alternative to the standard use of a pre- and post-contrast series. The VNC images provide high quality and reliability in imaging structurally altered splenic tissue, but show a potential weakness in the calculation of some mineralized lesions.
Spectral detector computed tomography (SDCT) is an innovative imaging technique in veterinary medicine that utilises simultaneous data acquisition at different energy levels using two rows of detectors. This technique provides several interesting applications which improve insights into tissue composition. One implementation is the generation of virtual non-contrast (VNC) images from post-contrast spectral CT data by identifying and subtracting iodine pixels. Preliminary studies suggest that VNC images may offer diagnostic quality comparable to true unenhanced (TUE) images in healthy dogs; however, this technique has yet to be evaluated in clinical patients. This study compared the Hounsfield units (HUs) measured in VNC to those in TUE images of canine hepatic pathologies, taking into account specific types of pathologies based on their imaging characteristics. The attenuation values of the VNC and TUE series were analysed using two one-sided t-tests (TOST), and the signal-to-noise ratio (SNR) was calculated for each region of interest (ROI). A 5-point Likert scale was utilised to assess image noise, quality, and iodine subtraction in the VNC images. A total of 287 ROIs were analysed in the liver, gallbladder, paravertebral muscle, and pancreatic body of 28 dogs with histopathologically confirmed hepatic pathologies. 92.61% of the hepatic ROIs displayed a “negligible” difference of ≤10 HUs between VNC and TUE images, with significant p-values of <0.05 maintained for all ROIs within the limit of ≤10 HUs in the TOST, confirming equivalence between the two imaging modalities. The image quality assessment indicated that SDCT-derived images provided equal or superior quality compared to conventional CT. Therefore, it can be concluded that VNC images calculated from SDCT data could be an alternative to conventional TUE images for hepatic pathologies.