Xiuling Liu

Xiuling Liu


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2017 in Materials
Verified
Journal Article
Open access
PDF file
CLCunguang Lou
Cunguang Lou
SWShuo Wang
Shuo Wang
TLtie liang
tie liang
CPChenyao Pang
Chenyao Pang
LHLei Huang
Lei Huang
XLXiuling Liu
Xiuling Liu
In the present study, we propose and develop a flexible pressure sensor based on the piezoresistive effect of multilayer graphene films on polyester textile. The pressure response results from the deformation of graphene conductive network structure and the changes in resistance. Here, we show that the graphene pressure sensor can achieve a sensitivity value of 0.012 kPa − 1 , the measurement range can be as high as 800 kPa, and the response time can reach to 50 ms. Subsequently, a stable in-shoe wireless plantar pressure measurement system is developed and dynamic pressure distribution is acquired in real-time. Overall, the graphene textile pressure sensor has the advantage of wide dynamic range, flexibility and comfort, which provides the high possibility for footwear evaluation, clinical gait analysis and pathological foot diagnosis.

1 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
CLCunguang Lou
Cunguang Lou
RLRuikai Li
Ruikai Li
ZLZhaopeng Li
Zhaopeng Li
TLtie liang
tie liang
ZWZihui Wei
Zihui Wei
XLXiuling Liu
Xiuling Liu
This paper describes the development of a graphene-based dry flexible electrocardiography (ECG) electrode and a portable wireless ECG measurement system. First, graphene films on polyethylene terephthalate (PET) substrates and graphene paper were used to construct the ECG electrode. Then, a graphene textile was synthesized for the fabrication of a wearable ECG monitoring system. The structure and the electrical properties of the graphene electrodes were evaluated using Raman spectroscopy, scanning electron microscopy (SEM), and alternating current impedance spectroscopy. ECG signals were then collected from healthy subjects using the developed graphene electrode and portable measurement system. The results show that the graphene electrode was able to acquire the typical characteristics and features of human ECG signals with a high signal-to-noise (SNR) ratio in different states of motion. A week-long continuous wearability test showed no degradation in the ECG signal quality over time. The graphene-based flexible electrode demonstrates comfortability, good biocompatibility, and high electrophysiological detection sensitivity. The graphene electrode also combines the potential for use in long-term wearable dynamic cardiac activity monitoring systems with convenience and comfort for use in home health care of elderly and high-risk adults.

21 November 2016 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
PXPeng Xiong
Peng Xiong
HWHongrui Wang
Hongrui Wang
MLMing Liu
Ming Liu
FLFeng Lin
Feng Lin
ZHZengguang Hou
Zengguang Hou
XLXiuling Liu
Xiuling Liu
As a primary diagnostic tool for cardiac diseases, electrocardiogram (ECG) signals are often contaminated by various kinds of noise, such as baseline wander, electrode contact noise and motion artifacts. In this paper, we propose a contractive denoising technique to improve the performance of current denoising auto-encoders (DAEs) for ECG signal denoising. Based on the Frobenius norm of the Jacobean matrix for the learned features with respect to the input, we develop a stacked contractive denoising auto-encoder (CDAE) to build a deep neural network (DNN) for noise reduction, which can significantly improve the expression of ECG signals through multi-level feature extraction. The proposed method is evaluated on ECG signals from the bench-marker MIT-BIH Arrhythmia Database, and the noises come from the MIT-BIH noise stress test database. The experimental results show that the new CDAE algorithm performs better than the conventional ECG denoising method, specifically with more than 2.40 dB improvement in the signal-to-noise ratio (SNR) and nearly 0.075 to 0.350 improvements in the root mean square error (RMSE).

8 April 2017 in International Journal of Machine Learning and Cybernetics
Verified
Journal Article
Closed access
PDF file
JYJianli Yang
Jianli Yang
YBYang Bai
Yang Bai
FLFeng Lin
Feng Lin
MLMing Liu
Ming Liu
ZHZengguang Hou
Zengguang Hou
XLXiuling Liu
Xiuling Liu

27 May 2019 in IEEE Access
Verified
Journal Article
Open access
JZJieshuo Zhang
Jieshuo Zhang
FLFeng Lin
Feng Lin
PXPeng Xiong
Peng Xiong
HDHaiman Du
Haiman Du
HZHong Zhang
Hong Zhang
XLXiuling Liu
Xiuling Liu
Novel techniques in deep learning networks are proposed for the staked Sparse Autoencoder (SAE) and the bagged decision tree (TreeBagger), achieving significant improvement in detection and localization of myocardial infarction (MI) from single-lead electrocardiograph (ECG) signals. With our layer-wise training strategies, the SAE-based diagnostic feature extraction network can automatically and steadily extract the deep distinguishing diagnostic features of the single-lead ECG signals and avoid the vanishing gradient problem. This feature extraction network is formed by stacking shallow SAEs. In addition, to automatically learn the stable distinctive feature expression of the label-less input ECG signals, this feature extraction network adopts unsupervised learning. Moreover, the TreeBagger classifier can optimize the results of multiple decision trees to more accurately detect and localize MI. Experiment and verification datasets include healthy controls, various types of MI with anterior, anterior lateral, anterior septal, anterior septal lateral, inferior, inferior lateral, inferior posterior, inferior posterior lateral, lateral, posterior, and posterior lateral, from PTB diagnostic ECG database. The evaluation results show that the new techniques can effectively and accurately detect and localize the MI pathologies. For MI detection, the accuracy, the sensitivity and the specificity rates achieve as high as 99.90%, 99.98%, and 99.52% respectively. For MI localization, we obtain consistent results with the accuracy 98.88%, sensitivity 99.95%, and specificity 99.87%. Comparative studies are conducted with the state-of-the-art techniques, and significant improvements by our methods are presented in the context. Success in the development of the accurate and comprehensive tool greatly helps the cardiologists in detection and localization of the single-lead ECG signals of MI.

1 May 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
PXPeng Xiong
Peng Xiong
YXYanping Xue
Yanping Xue
JZJieshuo Zhang
Jieshuo Zhang
MLMing Liu
Ming Liu
HDHaiman Du
Haiman Du
XLXiuling Liu
Xiuling Liu