Objective: : To evaluate the accuracy of three-dimensional (3D) stereophotogrammetry by comparing it with the direct anthropometry and digital photogrammetry methods. The reliability of 3D stereophotogrammetry was also examined. Materials and Methods: : Six profile and four frontal parameters were directly measured on the faces of 80 participants. The same measurements were repeated using two-dimensional (2D) photogrammetry and 3D stereophotogrammetry (3dMDflex System, 3dMD, Atlanta, Ga) to obtain images of the subjects. Another observer made the same measurements for images obtained with 3D stereophotogrammetry, and interobserver reproducibility was evaluated for 3D images. Both observers remeasured the 3D images 1 month later, and intraobserver reproducibility was evaluated. Statistical analysis was conducted using the paired samples t -test, intraclass correlation coefficient, and Bland-Altman limits of agreement. Results: : The highest mean difference was 0.30 mm between direct measurement and photogrammetry, 0.21 mm between direct measurement and 3D stereophotogrammetry, and 0.5 mm between photogrammetry and 3D stereophotogrammetry. The lowest agreement value was 0.965 in the Sn-Pro parameter between the photogrammetry and 3D stereophotogrammetry methods. Agreement between the two observers varied from 0.90 (Ch-Ch) to 0.99 (Sn-Me) in linear measurements. For intraobserver agreement, the highest difference between means was 0.33 for observer 1 and 1.42 mm for observer 2. Conclusions: : Measurements obtained using 3D stereophotogrammetry indicate that it may be an accurate and reliable imaging method for use in orthodontics.
24 January 2023 in Orthodontics & Craniofacial Research
Objective: To evaluate the social smile symmetry using three-dimensional (3D) stereophotogrammetric images. Materials and Methods: The study was conducted with 3D facial images of 30 individuals (age range 13–25 years). The rest position was considered as the reference image and the social smile image was aligned on this image using the best-fit alignment method. The spatial differences between the same points established on both images using 3D analyses were determined for right and left points in X, Y, and Z planes. Results: The highest difference related to spatial distance in right and left points was −0.56 mm (95% confidence interval [CI], −1.19, 0.06 mm) between right and left commissure (Com) points. The difference was not significant, and the Bland-Altman upper and lower limits were −3.85 mm and 2.71 mm, respectively. The highest difference for the transversal plane was found in Com points, similarly to the spatial distance (mean: 0.50 mm, 95% CI, −2.62, 1.02 mm). The differences between the changes in the left and right points in the Y and Z plane were not significant ( P > .05). Conclusions: The social smile was observed to show asymmetry in varying amounts in the different directions. Asymmetry increases in some cases, specifically for the corners of the mouth.