Limited-angle iterative reconstruction (LAIR) reduces the radiation dose required for computed tomography (CT) imaging by decreasing the range of the projection angle. We developed an image-quality-based stopping-criteria method with a flexible and innovative instrument design that, when combined with LAIR, provides the image quality of a conventional CT system. This study describes the construction of different scan acquisition protocols for micro-CT system applications. Fully-sampled Feldkamp (FDK)-reconstructed images were used as references for comparison to assess the image quality produced by these tested protocols. The insufficient portions of a sinogram were inpainted by applying a context encoder (CE), a type of generative adversarial network, to the LAIR process. The context image was passed through an encoder to identify features that were connected to the decoder using a channel-wise fully-connected layer. Our results evidence the excellent performance of this novel approach. Even when we reduce the radiation dose by 1/4, the iterative-based LAIR improved the full-width half-maximum, contrast-to-noise and signal-to-noise ratios by 20% to 40% compared to a fully-sampled FDK-based reconstruction. Our data support that this CE-based sinogram completion method enhances the efficacy and efficiency of LAIR and that would allow feasibility of limited angle reconstruction.

7 January 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CHChia-Jui Hsieh
Chia-Jui Hsieh
SJShih-Chun Jin
Shih-Chun Jin
Jyh-Cheng ChenJyh-Cheng Chen
Jyh-Cheng Chen
CKChih-Wei Kuo
Chih-Wei Kuo
RWRuei-Teng Wang
Ruei-Teng Wang
WCWoei-Chyn Chu
Woei-Chyn Chu
To further reduce the noise and artifacts in the reconstructed image of sparse-view CT, we have modified the traditional total variation (TV) methods, which only calculate the gradient variations in x and y directions, and have proposed 8- and 26-directional (the multi-directional) gradient operators for TV calculation to improve the quality of reconstructed images. Different from traditional TV methods, the proposed 8- and 26-directional gradient operators additionally consider the diagonal directions in TV calculation. The proposed method preserves more information from original tomographic data in the step of gradient transform to obtain better reconstruction image qualities. Our algorithms were tested using two-dimensional Shepp–Logan phantom and three-dimensional clinical CT images. Results were evaluated using the root-mean-square error (RMSE), peak signal-to-noise ratio (PSNR), and universal quality index (UQI). All the experiment results show that the sparse-view CT images reconstructed using the proposed 8- and 26-directional gradient operators are superior to those reconstructed by traditional TV methods. Qualitative and quantitative analyses indicate that the more number of directions that the gradient operator has, the better images can be reconstructed. The 8- and 26-directional gradient operators we proposed have better capability to reduce noise and artifacts than traditional TV methods, and they are applicable to be applied to and combined with existing CT reconstruction algorithms derived from CS theory to produce better image quality in sparse-view reconstruction.

18 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
WCWen-Hsiang Chou
Wen-Hsiang Chou
CWCheng-Han Wu
Cheng-Han Wu
SJShih-Chun Jin
Shih-Chun Jin
Jyh-Cheng ChenJyh-Cheng Chen
Jyh-Cheng Chen
Graphics processing units (GPUs) facilitate massive parallelism and high-capacity storage, and thus are suitable for the iterative reconstruction of ultrahigh-resolution micro computed tomography (CT) scans by on-the-fly system matrix (OTFSM) calculation using ordered subsets expectation maximization (OSEM). We propose a finite state automaton (FSA) method that facilitates iterative reconstruction using a heterogeneous multi-GPU platform through parallelizing the matrix calculations derived from a ray tracing system of ordered subsets. The FSAs perform flow control for parallel threading of the heterogeneous GPUs, which minimizes the latency of launching ordered-subsets tasks, reduces the data transfer between the main system memory and local GPU memory, and solves the memory-bound of a single GPU. In the experiments, we compared the operation efficiency of OS-MLTR for three reconstruction environments. The heterogeneous multiple GPUs with job queues for high throughput calculation speed is up to five times faster than the single GPU environment, and that speed up is nine times faster than the heterogeneous multiple GPUs with the FIFO queues of the device scheduling control. Eventually, we proposed an event-triggered FSA method for iterative reconstruction using multiple heterogeneous GPUs that solves the memory-bound issue of a single GPU at ultrahigh resolutions, and the routines of the proposed method were successfully executed on each GPU simultaneously.

1 January 2015
Verified
Book Chapter
Closed access
PDF file
STShih-Huan Tu
Shih-Huan Tu
YCYa-Chen Chen
Ya-Chen Chen
THTzu-Chien Hsiao
Tzu-Chien Hsiao
SJShih-Chun Jin
Shih-Chun Jin
JCJyh-Cheng Chen
Jyh-Cheng Chen

1 October 2013
Verified
Conference Paper
Closed access
SJShih-Chun Jin
Shih-Chun Jin
JCJyh-Cheng Chen
Jyh-Cheng Chen
Computed tomography (CT) has evolved into an indispensable imaging method in clinical routine for a long time. It gives us high resolution, high contrast and non-invasive tomographic images in a brief scan time. However, their high radiation dose is an important issue to be solved in CT system development. Iterative algorithms can give us better image quality than analytical types and reduce some artifact effectively. However, they are not only time consuming, but also need very large-scale memory size. In this study, we reduce our projection data to <;180-degree limited angle reconstruction, which was based on compressive sensing (CS) criteria and total variation (TV) minimization. This is a computer simulation study combined with CPU and graphic processing units (GPUs). We developed a 3D system matrix in which ray-tracing and circular redundancy technique were included. All CT image data were collected by our homemade micro-FT/CT dual modality system and reconstructed by model based post total-variation constrained algebraic reconstruction technique (ART-TV) algorithm, inner total-variation constrained expectation-maximization (TV-EM) and post total-variation constrained expectation-maximization (EM-TV) in transmission types. The reconstruction volume was 216 × 216 × 384 by 4 × 4 binning of the detector size. There is only 90-degree angular sampling range with 1 degree/projection. Some figures of merit (FOMs) such as rootmean-square error (RMSE), universal quality index (UQI) and coefficient of variation (CV) were used to evaluate image quality. Although now the total speed up ratio is about 1.3 × than CPU multi-threading but compare to our previous study, we push our reconstruction scale from simulated 16 ×16 × 16 and 32 × 34 detector size to the size of a realistic scan. Our study demonstrates that statistic reconstruction technique (SRT) with <; 180-degree limited angle reconstruction can produce low-dose CT images.

4 March 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
KSKun-Long Shih
Kun-Long Shih
SJShih-Chun Jin
Shih-Chun Jin
YWYu-Hong Wang
Yu-Hong Wang
TTTrang Thi Ngoc Tran
Trang Thi Ngoc Tran
Jyh-Cheng ChenJyh-Cheng Chen
Jyh-Cheng Chen
Cone-beam computed tomography (CBCT) is widely used in dental imaging, small animal imaging, radiotherapy, and non-destructive industrial inspection. The quality of CBCT images depends on the precise knowledge of the CBCT system’s alignment. We introduce a distinct procedure, ‘precision alignment loop (PAL)’, to calibrate any CBCT system with a circular trajectory. We describe the calibration procedure by using a line-beads phantom, and how PAL determines the misalignments from a CBCT system. PAL also yields the uncertainties in the simulated calibration to give an estimate of the errors in the misalignments. From the analytical simulations, PAL can precisely obtain the source-to-rotation axis distance, and the geometric center G , ‘the point in z -axis meets the detector’, where the z -axis is coincident with the line from the x-ray source that intersects the axis of the rotation orthogonally. The uncertainties of three misalignment angles of the detector are within ±0.05°, which is close to ±0.04° for the results of Yang et al (2017 Med. Phys. 44 1692), but our method is easy and simple to implement. Our distinct procedure, on the other hand, yields the calibration of a micro-CT system and an example of reconstructed images, showing our calibration method for the CBCT system to be simple, precise, and accurate.