Neural undersampling of the retinal image limits the range of spatial frequencies that can be represented veridically by the array of retinal ganglion cells conveying visual information from eye to brain. Our goal was to demarcate the neural bandwidth and local anisotropy of veridical perception, unencumbered by optical imperfections of the eye, and to test competing hypotheses that might account for the results. Using monochromatic interference fringes to stimulate the retina with high-contrast sinusoidal gratings, we measured sampling-limited visual resolution along eight meridians from 0° to 50° of eccentricity. The resulting isoacuity contour maps revealed all of the expected features of the human array of retinal ganglion cells. Contours in the radial fringe maps are elongated horizontally, revealing the functional equivalent of the anatomical visual streak, and are extended into nasal retina and superior retina, indicating higher resolution along those meridians. Contours are larger in diameter for radial gratings compared to tangential or oblique gratings, indicating local anisotropy with highest bandwidth for radially oriented gratings. Comparison of these results to anatomical predictions indicates acuity is proportional to the sampling density of retinal ganglion cells everywhere in the retina. These results support the long-standing hypothesis that “pixel density” of the discrete neural image carried by the human optic nerve limits the spatial bandwidth of veridical perception at all retinal locations.
We measured the S-cone contrast threshold for stimuli of different size modulated along the white −90 deg direction in the isoluminant plane of DKL color space. The stimuli were presented at eccentricities of 5–30 deg in the horizontal temporal retinal meridian. Ricco's area of complete spatial summation was estimated using a bilinear fit of the log threshold/log area function. Ricco's area increased towards the retinal periphery to include an increasing number of S-cones while remaining 1.6–1.8 times larger than the dendritic field area of the small bistratified and parasol retinal ganglion cells. Assuming constant coverage factor by the dendritic field, Ricco's area incorporated a constant number (three to four) of small bistratified cells. It was also found that the threshold contrast for stimuli that matched Ricco's area was constant across the studied eccentricity range, similar to previous findings for achromatic vision. Our data support the point of view that this invariance is the result of a constant number of cells involved in stimulus detection.
We investigated the classical question of why visual acuity decreases with decreasing retinal illuminance by holding retinal eccentricity fixed while illumination varied. Our results indicate that acuity is largely independent of illuminance at any given retinal location, which suggests that under classical free-viewing conditions acuity improves as illumination increases from rod threshold to rod saturation because the retinal location of the stimulus is permitted to migrate from a peripheral location of maximum sensitivity but poor acuity to the foveal location of maximum acuity but poor sensitivity. Comparison with anatomical sampling density of retinal neurons suggests that mesopic acuity at all eccentricities and scotopic acuity for eccentricities beyond about 20° is limited by the spacing of midget ganglion cells. In central retina, however, scotopic acuity is further limited by spatial filtering due to spatial summation within the large, overlapping receptive fields of the A-II class of amacrine cells interposed in the rod pathway between rod bipolars and midget ganglion cells. Our results offer a mechanistic interpretation of the clinical metrics for low-luminance visual dysfunction used to monitor progression of retinal disease.
1 August 2009 in Investigative Ophthalmology & Visual Science
Purpose. To compare directly the robustness of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), frequency-doubling perimetry (FDP), and grating-resolution perimetry (GRP) stimuli to different degrees of intraocular stray light induced by commercially available opacity-containing filters.
We wished to devise a measure of dissimilarity (D) which could predict psychophysical discrimination performance for Snellen letter pairs in peripheral vision. Threshold size for discriminating 33 pairs of Snellen letters was measured at 30 degrees eccentricity in the nasal retina for two subjects. D was computed for each pair by performing an overlap subtraction in the spatial domain, followed by a Fast Fourier Transform on this difference image, and dividing the total power in the resultant 'difference spectrum' by the sum of the powers of the individual letter spectra. A plot of D vs. psychophysical threshold letter size gave a mean correlation of R = -0.81. When D was calculated for letters that were low-pass filtered at different cut-off frequencies, the correlation with psychophysical performance was greatest when cut-off was between 1.25-1.9 cycles/letter (R = -0.85). Conversely, when the difference spectrum was high-pass filtered at different cut-off frequencies, the correlation decreased continuously as the cut-off increased. These results imply that the band of frequencies between zero and 1.25 cycles/letter are most important for letter discrimination in peripheral vision.