Ajay Kapur

Dr. Ajay Kapur

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Practical Radiation Oncology
Verified
Journal Article
Closed access
SESuzanne B. Evans
Suzanne B. Evans
DCDaylian Cain
Daylian Cain
AKAjay Kapur
Ajay Kapur
DBDerek Brown
Derek Brown
TPTodd Pawlicki
Todd Pawlicki

17 August 1999 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
AKAjay Kapur
Ajay Kapur
CMChang-Ming Ma
Chang-Ming Ma
Restricted mass collision stopping-power ratios for electron beams from a scatter-foil medical linear accelerator (Varian Clinac 2100C) were calculated for various combinations of beams, phantoms and detector materials using the Monte Carlo method. The beams were of nominal energy 6, 12 or 20 MeV, with square dimensions 1 × 1 cm2 to 10 × 10 cm2. They were incident at nominal SSDs of 100 or 120 cm and inclined at 90° or 30° to the surface of homogeneous water phantoms or water phantoms interspersed with layered lung or bone-like materials. The broad beam water-to-air stopping-power ratios were within 1.3% of the AAPM TG21 protocol values and consistent with the results of Ding et al to within 0.2%. On the central axis the stopping-power ratio variations for narrow beams compared with normally incident broad beams were 0.1% or less for water-to-LiF-100, graphite, ferrous sulfate dosimeter solution, polystyrene and PMMA, 0.5% for water-to-silicon and 1% for water-to-air and water-to-photographic-film materials. The transverse variations of the stopping-power ratios were up to 4% for water-to-silicon, 7% for water-to-photographic-film materials and 10% for water-to-air in the penumbral regions (where the dose was 10% of the global dose maximum) at shallow depths compared with the values at the same depths on the central axis. In the inhomogeneous phantoms studied, the stopping-power ratio correction factors varied more significantly for air, followed by photographic materials and silicon, at various depths on the central axis in the heterogeneous regions. For the simple layered phantoms studied, the estimation of the stopping-power ratio correction factors based on the relative electron-density derived effective depth approach yielded results that were within 0.5% of the Monte Carlo derived values for all the detector materials studied.

1 November 2017 in Practical Radiation Oncology
Verified
Journal Article
Closed access
AKAjay Kapur
Ajay Kapur
NANilda Adair
Nilda Adair
MOMildred O’bRien
Mildred O’bRien
NNNikoleta Naparstek
Nikoleta Naparstek
TCThomas Cangelosi
Thomas Cangelosi
LPLouis Potters
Louis Potters

18 April 2022 in Advances in Radiation Oncology
Verified
Journal Article
Open access
AKAjay Kapur
Ajay Kapur
BRBrett Rudin
Brett Rudin
LPLouis Potters
Louis Potters
It has been reported that adversarial growth during traumatic events potentially enhances coping with sequelae. The purpose of this work was to assess posttraumatic growth (PTG) among radiation medicine staff members at the individual level as well as changes in perceptions of departmental culture after the COVID-19 pandemic. An anonymous PTG inventory (PTGI) survey comprising 21 indicators was disseminated to all 213 members of our multicenter radiation department to measure perceptions of change in personal, interpersonal-relationship, and philosophy of life factors using principal-factor analysis. Additionally, 8 department safety-culture indicators from the National Hospital Patient Safety Culture Survey developed by the Agency for Healthcare Research and Quality were included to assess changes in department safety-culture perceptions verses a prepandemic survey. The survey was repeated 15 months later to assess longitudinal trends. With a 56.3% survey-response rate, PTGI factor analysis yielded Cronbach's alpha values exceeding 0.90 for the 3 aforementioned PTG factors. The average growth per indicator was 2.3 (out of 5.0), which fell between small and moderate. The values were 2.4 (personal), 2.1 (interpersonal), and 1.6 (philosophy) for the 3 factors. The total PTGI score (47.7 ± 28.3 out of 105 points) was lower for masked, patient-facing, frontline workers members (41.8 ± 28.4) compared with others (53.1 ± 27.3, P value .001). For the Agency for Healthcare Research and Quality survey there was an improvement of 15% in perceptions of department safety culture, and 7 of the 8 indicators showed improvements compared with baseline. The follow-up survey demonstrated overall sustained findings, albeit with a trend toward declining PTG scores for nonfrontline workers, notably in interpersonal relationships (47.4 ± 27.0, P value .05). A fair-to-moderate degree of PTG was observed in personal and interpersonal relationship factors whereas least growth was noted in spiritual and religious beliefs. Perceptions of department patient-safety culture improved substantially. Sustained improvements were thus perceived at the individual and department levels.

6 November 2025 in Current Oncology
Verified
Journal Article
Open access
PDF file
LTLeila Tchelebi
Leila Tchelebi
AKAjay Kapur
Ajay Kapur
CEClary Evans
Clary Evans
Purpose/Objective(s): Adjuvant radiation therapy (RT) is an effective treatment in the management of patients with breast cancer. Evidence supports both standard fractionation and, more recently, moderate hypofractionation and ultra hypofractionation leading to a potential diversity of clinical practice. Whether or not physicians at main academic centers adopt hypofractionated regimens more readily than those working at community centers is not known. Practice patterns were analyzed within our large healthcare network comprising one main and eight community sites before and after 2020. Materials/Methods: Patients treated with adjuvant breast RT between 2017 and 2022 in our radiation oncology department were identified. Treatment techniques were evaluated: standard fractionation (25–28 fractions to 50–50.4 Gy), moderate hypofractionation (15–16 fractions to 40.05–42.56 Gy), and ultra hypofractionation (5 fractions of 26–30 Gy) for intact breast, partial breast, and chest wall cases. Use of each technique was compared between the main academic center (Main) versus eight community sites (Community) in two time periods, 2017–2019 and 2020–2022. Differences were assessed using z-ratios for the difference between independent proportions. Results: There was a statistically significant decrease in the use of standard fractionation for intact breast and chest wall cases from the early to the late period at both the community sites and the main center; however, a higher proportion of patients were treated with standard fractionation at the community sites versus the main center in the late period (7.8% community versus 2.0% main, p < 0.01 for intact breast and 80.7% community versus 37.4% main, p < 0.01 for chest wall). There was a statistically significant increase in the use of hypofractionation for intact breast and chest wall cases from the early to the late period at both the community sites and the main center; however, a higher proportion of patients were treated with hypofractionation at the main center versus the community sites during the late period (92.2% community versus 98.0% main, p < 0.01 for intact breast and 19.3% community versus 62.6% main, p < 0.01). Conclusions: The present study shows that recent trial evidence supporting the use of shorter RT treatments changed practice among providers more rapidly at our main academic center versus our community sites. The reasons for this difference are not known; however, standardization of treatment by implementation of an adjuvant RT treatment algorithm may facilitate uniform care among patients with breast cancer and we are investigating the impact of this approach.