Bruna Alves

Ms. Bruna Alves

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BABruna Alves
Bruna Alves
Alessandro FantoniAlessandro Fantoni
Alessandro Fantoni
JMJosé Pedro Matos
José Pedro Matos
JCJoão Costa
João Costa
Manuela VieiraManuela Vieira
Manuela Vieira
This study represents a preliminary proof of concept intended to demonstrate the feasibility of using a single-point LiDAR sensor for wearable gait analysis. The study presents a low-cost wearable sensor system that integrates a single-point LiDAR module and IoT connectivity to assess Gait Cycle Duration (GCD) and gait symmetry in real time. The device is positioned on the medial side of the calf to detect the contralateral limb crossing—used as a proxy for mid-stance—enabling the computation of GCD for both limbs and the derivation of the Symmetry Ratio and Symmetry Index. This was conducted under simulated walking at three cadences (slow, normal and fast). GCD estimated by the sensor was compared against the visual annotation with Kinovea®, showing reasonable agreement, with most cycle-wise relative differences below approximately 13% and both methods capturing similar symmetry trends. The wearable system operated reliably across different speeds, with an estimated materials cost of under 100 € and wireless data streaming to a cloud dashboard for real-time visualization. Although the validation is preliminary and limited to a single healthy participant and a video-based reference, the results support the feasibility of a photonic, IoT-based approach for portable and objective gait assessment, motivating future studies with larger and clinical cohorts and gold-standard references to quantify accuracy, repeatability and clinical utility.

14 October 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
BABruna Alves
Bruna Alves
Alessandro FantoniAlessandro Fantoni
Alessandro Fantoni
JMJosé Pedro Matos
José Pedro Matos
JCJoão Costa
João Costa
Manuela VieiraManuela Vieira
Manuela Vieira
The sensor effectively detected mid-stance events and adapted to variations in gait cadence. Comparison with Kinovea® showed a reasonable agreement, with most relative differences under 13%. Both methods identified similar gait symmetry trends. The results confirm the feasibility of the proposed system for real-time gait assessment across different walking speeds. Although preliminary, this validation supports the potential of the device as a low-cost, portable, and objective tool for functional evaluation in prosthetic rehabilitation. Further studies are needed to expand validation with clinical populations and laboratory-grade reference systems.