Jean-Marc GIRAULT

Prof. Jean-Marc GIRAULT

1. Department of Electronics and Control Engineering, Ecole Supérieure d’Electronique de l’Ouest, 49107 Angers, France
+1
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 1998 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Jean-Marc GIRAULTJean-Marc GIRAULT
Jean-Marc GIRAULT
FOF. Ossant
F. Ossant
Abdeldjalil OuahabiAbdeldjalil Ouahabi
Abdeldjalil Ouahabi
DKD. Kouame
D. Kouame
FPF. Patat
F. Patat
In the field of biological tissue characterization, fundamental acoustic attenuation properties have been demonstrated to have diagnostic importance. Attenuation caused by scattering and absorption shifts the instantaneous spectrum to the lower frequencies. Due to the time-dependence of the spectrum, the attenuation phenomenon is a time-variant process. This downward shift may be evaluated either by the maximum energy frequency of the spectrum or by the center frequency. In order to improve, in strongly attenuating media, the results given by the short-time Fourier analysis and the short-time parametric analysis, we propose two approaches adapted to this time-variant process: an adaptive method and a time-varying method. Signals backscattered by an homogeneous medium of scatterers are modeled by a computer algorithm with attenuation values ranging from 1 to 5 dB/cm MHz and a 45 MHz transducer center frequency. Under these conditions, the preliminary results obtained with the proposed time-variant methods, compared with the classical short-time Fourier analysis and the short-time auto-regressive (AR) analysis, are superior in terms of standard deviation (SD) of the attenuation coefficient estimate. This study, based on nonstationary AR spectral estimation, promises encouraging perspectives for in vitro and in vivo applications both in weakly and highly attenuating media.

1 October 2010
Verified
Conference Paper
Closed access
CQCeline Quinsac
Celine Quinsac
ABAdrian Basarab
Adrian Basarab
Jean-Marc GIRAULTJean-Marc GIRAULT
Jean-Marc GIRAULT
DKDenis Kouame
Denis Kouame
This paper proposes a comparison between an established (used in magnetic resonance imaging) and a innovative compressed sensing (CS) approach, both adapted to ultrasound (US) imaging. Two undersampling patterns suited to US imaging were investigated in each approach on simulated and in vivo radio-frequency US images. Reconstructions of simulated and in vivo US images using CS show minimal information loss. The best strategy (minimising the errors of reconstruction) was a uniform random sampling in the two directions of the spatial RF US image associated with the reconstruction of its k-space.

15 April 2003 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
DKD. Kouame
D. Kouame
Jean-Marc GIRAULTJean-Marc GIRAULT
Jean-Marc GIRAULT
JRJ.-P. Remenieras
J.-P. Remenieras
JCJ.-P. Chemla
J.-P. Chemla
MLM. Lethiecq
M. Lethiecq
For pt.I see ibid., vol.50, no.3, p.267-78 (2003). This paper presents an application of continuous wave ultrasound Doppler velocity measurements to two-phase flow in pipes. In many petroleum wells, the multiphase flow is separated into two phases: the first is a liquid phase and the second is a gas phase with small scatterers. The problem of multiphase velocity profile measurements has not been satisfactorily solved by classical approaches due to the multiphase nature of the fluid and the presence of colored noise, which introduces a significant bias in classical frequency estimators. We propose the use of resolution frequency techniques to overcome the classical limitations. Direct estimation of Doppler frequency then obtained using either time frequency maximum frequency or arguments of poles of the parametric model that identifies the Doppler part of the signal is discussed. The tests made with synthetic Doppler signals and two-phase flow have demonstrated the excellent performance of the high resolution techniques based on reassignment and parametric techniques.

1 September 2010 in Signal Processing
Verified
Journal Article
Closed access
Jean-Marc GIRAULTJean-Marc GIRAULT
Jean-Marc GIRAULT
DKDenis Kouamé
Denis Kouamé
Abdeldjalil OuahabiAbdeldjalil Ouahabi
Abdeldjalil Ouahabi

15 April 2018 in Entropy
Verified
Journal Article
Open access
Jean-Marc GIRAULTJean-Marc GIRAULT
Jean-Marc GIRAULT
Anne Humeau-HeurtierAnne Humeau-Heurtier
Anne Humeau-Heurtier
Several entropy measures are now widely used to analyze real-world time series. Among them, we can cite approximate entropy, sample entropy and fuzzy entropy (FuzzyEn), the latter one being probably the most efficient among the three. However, FuzzyEn precision depends on the number of samples in the data under study. The longer the signal, the better it is. Nevertheless, long signals are often difficult to obtain in real applications. This is why we herein propose a new FuzzyEn that presents better precision than the standard FuzzyEn. This is performed by increasing the number of samples used in the computation of the entropy measure, without changing the length of the time series. Thus, for the comparisons of the patterns, the mean value is no longer a constraint. Moreover, translated patterns are not the only ones considered: reflected, inversed, and glide-reflected patterns are also taken into account. The new measure (so-called centered and averaged FuzzyEn) is applied to synthetic and biomedical signals. The results show that the centered and averaged FuzzyEn leads to more precise results than the standard FuzzyEn: the relative percentile range is reduced compared to the standard sample entropy and fuzzy entropy measures. The centered and averaged FuzzyEn could now be used in other applications to compare its performances to those of other already-existing entropy measures.

13 September 2013 in Physics in Medicine & Biology
Verified
Journal Article
Open access
SMS Mouysset
S Mouysset
HZH Zbib
H Zbib
SSS Stute
S Stute
Jean-Marc GIRAULTJean-Marc GIRAULT
Jean-Marc GIRAULT
JCJ Charara
J Charara
CTC Tauber
C Tauber
Segmentation is often required for the analysis of dynamic positron emission tomography (PET) images. However, noise and low spatial resolution make it a difficult task and several supervised and unsupervised methods have been proposed in the literature to perform the segmentation based on semi-automatic clustering of the time activity curves of voxels. In this paper we propose a new method based on spectral clustering that does not require any prior information on the shape of clusters in the space in which they are identified. In our approach, the p-dimensional data, where p is the number of time frames, is first mapped into a high dimensional space and then clustering is performed in a low-dimensional space of the Laplacian matrix. An estimation of the bounds for the scale parameter involved in the spectral clustering is derived. The method is assessed using dynamic brain PET images simulated with GATE and results on real images are presented. We demonstrate the usefulness of the method and its superior performance over three other clustering methods from the literature. The proposed approach appears as a promising pre-processing tool before parametric map calculation or ROI-based quantification tasks.