This study investigates the heat transfer coefficient (HTC) during flow condensation inside smooth inclined tubes, analyzing the combined effects of flow orientation, fluid properties and flow characteristics on the thermal performance. The literature review indicates that the channel inclination effect on the HTC remains insufficiently understood, highlighting the need for further investigation. Thus, a comprehensive experimental database comprising 4944 data points was compiled from 24 studies, including all flow directions, from upward, to horizontal, downward, and intermediate orientations. The study reveals that the influence of flow inclination on the HTC can be ruled by a criterion based on the liquid film thickness Froude number, . At > 4.75, the effect of flow inclination becomes negligible, while under < 4.75, the inclination can have a considerable effect on the HTC. The experimental data show that at low Froude numbers, upward flow typically exhibits higher HTC compared to downward flow, attributed to enhanced interfacial turbulence caused by opposing gravitational and shear forces. In contrast, under vertical downward flow, the annular pattern is more prominent, with reduced interfacial disturbances, limiting HTC performance. The compiled experimental database for inclined channels was compared against an update list of prediction methods, including seven correlations incorporating the inclination angle as an input parameter. Additionally, a new simple correction factor including the effect of inclined tubes was proposed based on the flow inclination angle and on the liquid film thickness Froude number. The proposed correction factor improved the prediction of well-ranked correlations in the literature by over 20% for stratified flow pattern conditions and by more than 5% for low Froude number values. These findings present new insights into how tube inclination can affect heat transfer in a two-phase flow.
In this study, the influence of flow orientation relative to the gravitational field on convective boiling behavior of R1336mzz(Z) was investigated. The microstructured heated surface was composed of fifteen pairs of Dual-V asymmetric microchannels and was combined with a tapered open-manifold, forming a heat sink with divergent cross-section. Flow boiling experiments with R1336mzz(Z) were conducted at saturation temperature of 33 °C and inlet degree of subcooling of 10 °C with the test section at five distinct positions, corresponding to vertical upward flow, inclined upward flow, horizontal flow, inclined downward flow, and vertical downward flow. For each orientation of the test section, four inlet mass velocity setpoints were selected, ranging from 100 to 600 kg/m²s, and all tests were conducted for increasing heat flux until the estimated heat transfer coefficient presented a sudden decrease. Top-view images of the two-phase flow in the heat sink were captured using a high-speed camera, in order to relate the topological phase distribution to the heat transfer coefficient and pressure drop behavior. Even though the investigated heat sink classifies as a microchannel under most criteria, the present results indicate that the flow orientation can change the mechanisms associated with the heat sink geometry that are responsible for the phase segregation and dumping backflows, which promote significant heat transfer enhancement, are influenced by flow orientation. In general, these effects become more pronounced under conditions of reduced mass velocity and heat flux.