Fabry disease (FD) is an X-linked disorder with α-galactosidase A deficiency. Males (>30 years) and females (>40 years) often present with cardiac manifestations, predominantly left ventricular hypertrophy (LVH). The aim of this study was to evaluate electrocardiographic (ECG) characteristics within FD patients to identify gender related differences, and to additionally explore the association of ECG parameters with structural and functional alterations on transthoracic echocardiography (TTE). Retrospective cross-sectional analysis of 45 FD patients with contemporaneous ECG and TTE was performed and compared to age and gender matched healthy controls. FD patients demonstrated alterations in several ECG parameters particularly in males, including prolonged P-wave duration (91 vs. 81 ms, p = 0.022), prolonged QRS duration (96 vs. 84 ms, p < 0.001), increased R-wave amplitude in lead I (8.1 vs. 5.7 mV, p = 0.047), increased Sokolow–Lyon index (25 vs. 19 mV, p = 0.002) and were more likely to meet LVH criteria (31% vs. 7%, p = 0.006). FD patients with impaired basal longitudinal strain (LS) on TTE were more likely to meet LVH criteria (41% vs. 0%, p = 0.018). Those with more advanced FD (increased LV wall thickness on TTE) were more likely to meet LVH criteria but additionally demonstrated prolonged ventricular depolarization (QRS duration 101 vs. 88 ms, p = 0.044). Therefore, alterations on ECG demonstrating delayed atrial activation, delayed ventricular depolarization and evidence of LVH were more often seen in male FD patients. Impaired basal LS, a TTE marker of early cardiac involvement, correlated with ECG abnormalities. Increased LV wall thickness on TTE, a marker of more advanced FD, was associated with more severe ECG abnormalities.
(1) Background: Ventricular arrhythmias (VAs) are a leading cause of morbidity and mortality in ischemic and non-ischemic heart disease. While automated implantable cardioverter–defibrillators (AICDs) are standard treatment for high-risk patients, predicting future VA post-implantation remains limited. This study evaluated echocardiographic and strain parameters for predicting VA risk in AICD recipients. (2) Methods: This retrospective cohort study included patients who underwent AICD implantation at Westmead Hospital, New South Wales, Australia (January 2014–May 2024). Pre-implant transthoracic echocardiograms (TTEs) were analysed for structural and functional parameters, including left-ventricular (LV) ejection fraction (LVEF), LV global longitudinal strain (GLS), mechanical dispersion (MD), and delta contraction duration (DCD). VA events, defined as appropriate AICD shock or anti-tachycardia pacing, were identified from electronic medical records and device checks. Univariate and multivariate Cox regression analyses were performed. (3) Results: Among 242 patients, 98 experienced VA events. Increased LV end-diastolic diameter, indexed LV mass, and right-ventricular basal diameter were associated with VA events (p < 0.05), whilst LVEF and GLS were not. LV dyssynchrony was greater in affected patients (MD 69.2 ms vs. 63 ms, p = 0.036; DCD 288.8 ms vs. 246.4 ms, p = 0.010). DCD was an independent predictor of VA events (HR 1.003; 95% CI: 1.000–1.006; p = 0.022). (4) Conclusions: DCD may improve risk stratification in AICD patients.