Antonio Anastasio

Mr. Antonio Anastasio


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2023 in Instruments
Verified
Journal Article
Open access
PDF file
MMMarco Mese
Marco Mese
AAAntonio Anastasio
Antonio Anastasio
ABAlfonso Boiano
Alfonso Boiano
VMVincenzo Masone
Vincenzo Masone
GOGiuseppe Osteria
Giuseppe Osteria
AVAntonio Vanzanella
Antonio Vanzanella
This contribution describes the acquisition and trigger system for the HEPD-02 calorimeter that will be used onboard the CSES-02 satellite for the CSES/Limadou mission. This mission arises from the collaboration between the Chinese Space Agency (CNSA) and the Italian Space Agency (ASI) and plans the realization of a constellation of satellites which will monitor ionospheric parameters supposed to be related to earthquakes. It will also monitor the solar activity and the interaction with the magnetosphere and will study the cosmic rays in low energy ranges, extending data from PAMELA and AMS. The CSES-02 satellite will be equipped with various instruments, including the High-Energy Particle Detector (HEPD-02), which was designed to measure the energy of particles coming from Van Allen belts. Signals from the HEPD-02 are acquired and digitized by an electronic board that also produces the trigger for the experiment. A new generation ASIC (CITIROC) for the amplification, shaping and memorization of signals from PMTs will be used on this board. The new ASIC allows the use of the peak detector feature, optimizing the acquisition of signals with different temporal characteristics. Along with this, new algorithms for trigger generation have been developed, providing trigger pre-scaling, concurrent trigger masks and Gamma Ray Burst detection. Using pre-scaled concurrent triggers will allow the study of very sensitive regions of a satellite’s orbit such as the South Atlantic Anomaly and polar regions and to detect rare events such as GRBs while still monitoring particle bursts. In this contribution, the progress status of this work will be presented along with the measurements and tests made to finalize the flight model of the board.

27 November 2025 in Particles
Verified
Journal Article
Open access
PDF file
Valentina ScottiValentina Scotti
Valentina Scotti
GOGiuseppe Osteria
Giuseppe Osteria
MMMarco Mese
Marco Mese
AAAntonio Anastasio
Antonio Anastasio
ABAlfonso Boiano
Alfonso Boiano
HQHaroon Akhtar Qureshi
Haroon Akhtar Qureshi
The study of Ultra-High-Energy Cosmic Rays is made possible by space telescopes that allow for the recording of signals generated by Extensive Air Showers (EAS) on the night side of the Earth’s atmosphere. One of the requirements for these telescopes is the detection of very low photon fluxes, achievable using the latest generation SiPMs characterized by high intrinsic gains, low power consumption, low weight, and robustness against accidental exposure to light. Despite these advantages, some technological issues still need to be addressed, such as the radiation hardness for operation in space. Therefore, the design of a SiPM-based focal surface for UHECR detection must consider the space qualification of SiPM arrays, with the development of compact arrays optimized for low dead-area focal surfaces. SiSMUV (SiPM-based Space Monitor for UV light) is a project dedicated to developing a compact and modular UV detector for use in space telescopes designed to study the fluorescence and Cherenkov signals produced by Ultra-High-Energy Cosmic Rays (UHECRs). Each SiSMUV module incorporates a matrix of SiPMs, a readout ASIC (Radioroc by Weeroc), and an FPGA into a monolithic block. This design enables the acquisition and processing of signals from the sensors. The system can connect to a PC for standalone operation or with back-end electronics for integration into more complex systems. In this paper, we will describe the prototype electronics, the experimental setup and the measurements performed to obtain parameters such as the gain of the SiPMs, and their photon detection efficiency (PDE). We will also present the firmware developed to interface with the readout ASIC and to transmit data to other peripherals.

21 November 2025 in Particles
Verified
Journal Article
Open access
PDF file
BPBeatrice Panico
Beatrice Panico
RARoberto Ammendola
Roberto Ammendola
AAAntonio Anastasio
Antonio Anastasio
DBDavide Badoni
Davide Badoni
BEBertaina Mario Edoardo
Bertaina Mario Edoardo
Valentina ScottiValentina Scotti
Valentina Scotti
POEMMA-Balloon with Radio (PBR) is designed as a payload for a NASA suborbital Super Pressure Balloon that will circle over the Southern Ocean and a mission duration as long as 50 days. The PBR instrument consists of a 1.1 m aperture Schmidt telescope similar to the POEMMA design with two cameras in its focal surface: a Fluorescence Camera (FC) and a Cherenkov Camera (CC). The CC camera is mainly devoted to the observation of cosmic-ray-induced high-altitude horizontal air showers (HAHAs) and search for neutrino-induced upward-going EAS. It will be made of 2048 SiPMs with a surface of 3 × 3 mm2 and a FoV of 12° by 6°, covering a spectral range of 320–900 nm. The CC camera is an innovative detector currently under construction. In this paper, information about its current status will be given.

5 May 2026 in Instruments
Verified
Journal Article
Open access
PDF file
LCLuigi Cimmino
Luigi Cimmino
FAFabio Ambrosino
Fabio Ambrosino
AAAntonio Anastasio
Antonio Anastasio
CACarla Aramo
Carla Aramo
VBVincenzo Bottiglieri
Vincenzo Bottiglieri
VTVincenzo Tramontano
Vincenzo Tramontano
We present the upgrade and performance evaluation of a silicon photomultiplier (SiPM)-based muon detector, originally designed and developed 15 years ago for radiation tracking applications in radiographic imaging with cosmic muons. The first use of the original assembly and scientific objectives of the detector was in the Mu-Ray project of the Italian National Institute for Nuclear Physics (INFN) for muon radiographic imaging of volcanoes. In addition to its initial uses and after being upgraded with Hamamatsu SiPMs, the detector has been employed in a series of measurement campaigns for the detection of underground cavities. Herein we describe the mechanical recovery process and the integration of modern electronic components aimed at extending the operational capabilities of the detector, with particular attention to the adaptation of the front-end electronics to a new DAQ system. The results of the detector’s characterization and calibration under controlled conditions will be presented, evaluating its current performance and suitability for muography applications in a new geophysical setting. The results confirm that, despite aging, the system remains a viable instrument for precision and reliable muon tracking.