Pieter van Doorn

Mr. Pieter van Doorn

Maastricht University, Maastricht, Limburg, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in Family Practice
Verified
Journal Article
Open access
PDF file
Pieter van DoornPieter van Doorn
Pieter van Doorn
ESEvelien I T de Schepper
Evelien I T de Schepper
RRRianne M Rozendaal
Rianne M Rozendaal
RORamon P G Ottenheijm
Ramon P G Ottenheijm
JLJohan van der Lei
Johan van der Lei
DSDieuwke Schiphof
Dieuwke Schiphof
Background: Shoulder pain is the third most common musculoskeletal complaint in primary care. The international guidelines for general practitioners (GPs) recommend a stepwise treatment of shoulder pain. Little is known about the actual distribution of these treatments in current practice. Objective: To gain insight in the incidence and current management of shoulder complaints in Dutch general practice. Methods: A retrospective cohort study was conducted using a health care database containing the full electronic medical records of approximately 200 000 patients in Dutch general practice. A search algorithm was constructed to identify incident cases of shoulder complaints from January 2012 to December 2017. Data on the management of shoulder complaints were manually validated in a random sample of 1000 cases. Results: The overall incidence of shoulder complaints was 30.3 (95% confidence interval 29.9–30.7) per 1000 person-years. More than half of the patients (58.6%) consulted their GP only once, 44.4% two times or more and 19.7% three times or more. For most patients (58.1%), the GP applied a wait-and-see policy or prescription of oral medication in the first consultation. However, no less than 42.9% of the patients were referred or received an injection already in the first consultation. Conclusions: There is a wide variety of treatments for shoulder complaints applied by the GP. Some patients are referred or received an injection already in the first consultation. The stepwise approach recommended by the guideline, might not always be applicable due to the diversity of patient- and shoulder characteristics presented in general practice.

24 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JBJara Sofia van Bergem
Jara Sofia van Bergem
Pieter van DoornPieter van Doorn
Pieter van Doorn
EHEva Hoogendoorn
Eva Hoogendoorn
DGDaphne Geerse
Daphne Geerse
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
State-of-the-art augmented reality (AR) glasses record their 3D pose in space, enabling measurements and analyses of clinical gait and balance tests. This study’s objective was to evaluate concurrent validity and test–retest reliability for common clinical gait and balance tests in people with Parkinson’s disease: Five Times Sit To Stand (FTSTS) and Timed Up and Go (TUG) tests. Position and orientation data were collected in 22 participants with Parkinson’s disease using HoloLens 2 and Magic Leap 2 AR glasses, from which test completion durations and durations of distinct sub-parts (e.g., sit to stand, turning) were derived and compared to reference systems and over test repetitions. Regarding concurrent validity, for both tests, an excellent between-systems agreement was found for position and orientation time series (ICC(C,1) > 0.933) and test completion durations (ICC(A,1) > 0.984). Between-systems agreement for FTSTS (sub-)durations were all excellent (ICC(A,1) > 0.921). TUG turning sub-durations were excellent (turn 1, ICC(A,1) = 0.913) and moderate (turn 2, ICC(A,1) = 0.589). Regarding test–retest reliability, the within-system test–retest variation in test completion times and sub-durations was always much greater than the between-systems variation, implying that (sub-)durations may be derived interchangeably from AR and reference system data. In conclusion, AR data are of sufficient quality to evaluate gait and balance aspects in people with Parkinson’s disease, with valid quantification of test completion durations and sub-durations of distinct FTSTS and TUG sub-parts.

18 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Pieter van DoornPieter van Doorn
Pieter van Doorn
DGDaphne Geerse
Daphne Geerse
JBJara Sofia van Bergem
Jara Sofia van Bergem
EHEva Hoogendoorn
Eva Hoogendoorn
ENEdward Nyman
Edward Nyman
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
The 10-m walk test (10MWT) is a stopwatch-based clinical mobility assessment. To better understand mobility limitations, 10MWT test completion times may be complemented with gait parameters like step length. State-of-the-art augmented reality (AR) glasses can potentially do this given their unique 3D-positional data from which gait parameters may be derived. We examined the test-retest reliability, concurrent validity, and face validity of gait parameters derived from AR glasses during a 10MWT in 20 people with Parkinson’s disease, performed at self-selected comfortable and fast-but-safe walking speeds. AR-derived 10MWT completion times and gait parameters (mean step length, cadence, and maximal gait speed) were compared across repetitions and with lab-based (Interactive Walkway) and clinical (stopwatch) reference systems. Good-to-excellent test-retest reliability statistics were observed for test completion times and gait parameters for all systems and conditions alike. Concurrent validity was demonstrated between AR, lab-based, and clinical references for test completion times (good-to-excellent agreement: ICC > 0.879) and gait parameters (excellent agreement: ICC > 0.942). Face validity was confirmed by significant differences in test completion times and gait parameters between speed conditions in a-priori expected directions. These findings support the conclusion that gait parameters can be derived reliably and validly from AR glasses in people with Parkinson’s disease.

8 October 2021 in Family Practice
Verified
Journal Article
Open access
PDF file
Pieter van DoornPieter van Doorn
Pieter van Doorn
DSDieuwke Schiphof
Dieuwke Schiphof
RRRianne M Rozendaal
Rianne M Rozendaal
RORamon P G Ottenheijm
Ramon P G Ottenheijm
JLJohan van der Lei
Johan van der Lei
ESEvelien I T de Schepper
Evelien I T de Schepper
Guidelines for shoulder pain in general practice recommend treatment with corticosteroid injections (CSI) if initial pain management fails. However, little is known about the actual use and safety of CSIs in treatment by general practitioners (GP). The objective of this study was to gain insight into the use and safety of CSIs for patients with a new episode of shoulder pain in general practice. A retrospective cohort study was conducted using a healthcare database containing the electronic medical records of approximately 200,000 patients in general practice. A search algorithm was constructed to identify patients with a new episode of shoulder pain between January 2012 and December 2017. Data on the use of CSIs in 2 random samples (n = 1,000) were manually validated for a 12-month period after the diagnosis. In total, 26% of the patients with a new episode of shoulder pain received a CSI. The patient’s age (OR 1.03, 95% CI 1.02–1.04) and a history of shoulder pain (OR 1.52, 95% CI 1.13–2.12) were significantly associated with the administration of a CSI. Half of the patients received the CSI in the first consultation. The patient’s age was positively associated with the likelihood of receiving the CSI in the first consultation (OR 1.01, 95% CI 1.00–1.02). No serious adverse reactions were recorded by the GP. In contrast to the guidelines, CSIs were frequently administered in the first consultation. Older patients and patients with a history of shoulder pain were more likely to receive a CSI for shoulder pain.

24 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Pieter van DoornPieter van Doorn
Pieter van Doorn
ENEdward Nyman
Edward Nyman
KWKoen Wishaupt
Koen Wishaupt
MKMarjolein M. van der Krogt
Marjolein M. van der Krogt
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
People with Parkinson’s disease (PD) experience mobility impairments that impact daily functioning, yet conventional clinical assessments provide limited insight into real-world mobility. This study evaluated motor-state classification and the concurrent validity of mobility metrics derived from augmented-reality (AR) glasses against a markerless motion capture system (Theia3D) during gamified AR exercises. Fifteen participants with PD completed five gamified AR exercises measured with both systems. Motor-state segments included straight walking, turning, squatting, and sit-to-stand/stand-to-sit transfers, from which the following mobility metrics were derived: step length, gait speed, cadence, transfer and squat durations, squat depth, turn duration, and peak turn angular velocity. We found excellent between-systems consistency for head position (X, Y, Z) and yaw-angle time series (ICC(c,1) > 0.932). The AR-based motor-state classification showed high accuracy, with F1-scores of 0.947–1.000. Absolute agreement with Theia3D was excellent for all mobility metrics (ICC(A,1) > 0.904), except for cadence during straight walking and peak angular velocity during turns, which were good and moderate (ICC(A,1) = 0.890, ICC(A,1) = 0.477, respectively). These results indicate that motor states and associated mobility metrics can be accurately derived during gamified AR exercises, verified in a controlled laboratory environment in people with mild to moderate PD, a necessary first step towards unobtrusive derivation of mobility metrics during in-clinic and at-home AR neurorehabilitation exercise programs.

2 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
JBJara Sofia van Bergem
Jara Sofia van Bergem
Pieter van DoornPieter van Doorn
Pieter van Doorn
EHEva Hoogendoorn
Eva Hoogendoorn
DGDaphne Geerse
Daphne Geerse
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
State-of-the-art augmented-reality (AR) glasses record their position and orientation in space, enabling measurements and analyses of clinical gait-and-balance tests. This study’s objective was to evaluate concurrent validity and test-retest reliability for common clinical gait-and-balance tests in people with Parkinson’s disease: the Five Times Sit-To-Stand (FTSTS) and Timed Up-and-Go (TUG) tests. Position and orientation data was collected in 22 participants with Parkinson's disease using HoloLens 2 and Magic Leap 2 AR glasses, from which test-completion durations and durations of distinct sub-parts (e.g., sit-to-stand, turning) were derived and compared to reference systems and over test repetitions. Regarding concurrent validity, for both tests an excellent between-systems agreement was found for position and orientation time series and test-completion durations. Between-systems agreement for FTSTS (sub-)durations were all excellent, while TUG turning sub-durations were excellent (turn 1) and moderate (turn 2). Regarding test-retest reliability, the within-system test-retest variation in test-completion times and sub-durations was always much greater than the between-systems variation, implying that these (sub-)durations may be derived interchangeably from AR and reference-system data. In conclusion, AR data are of sufficient quality to evaluate gait and balance in people with Parkinson's disease, with valid quantification of test-completion durations and sub-durations of distinct FTSTS and TUG sub-parts.