Daphne Geerse

Ms. Daphne Geerse


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DGDaphne Geerse
Daphne Geerse
BCBert Coolen
Bert Coolen
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect’s 3D body point’s time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point’s time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point’s time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters’ walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman’s bias and limits of agreement. Body point’s time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point’s time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained objectively in a quick, unobtrusive and patient-friendly manner.

5 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DGDaphne Geerse
Daphne Geerse
BCBert Coolen
Bert Coolen
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
Microsoft’s HoloLens, a mixed-reality headset, provides, besides holograms, rich position data of the head, which can be used to quantify what the wearer is doing (e.g., walking) and to parameterize such acts (e.g., speed). The aim of the current study is to determine test-retest reliability, concurrent validity, and face validity of HoloLens 1 for quantifying spatiotemporal gait parameters. This was done in a group of 23 healthy young adults (mean age 21 years) walking at slow, comfortable, and fast speeds, as well as in a group of 24 people with Parkinson’s disease (mean age 67 years) walking at comfortable speed. Walking was concurrently measured with HoloLens 1 and a previously validated markerless reference motion-registration system. We comprehensively evaluated HoloLens 1 for parameterizing walking (i.e., walking speed, step length and cadence) in terms of test-retest reliability (i.e., consistency over repetitions) and concurrent validity (i.e., between-systems agreement), using the intraclass correlation coefficient (ICC) and Bland–Altman’s bias and limits of agreement. Test-retest reliability and between-systems agreement were excellent for walking speed (ICC ≥ 0.861), step length (ICC ≥ 0.884), and cadence (ICC ≥ 0.765), with narrower between-systems than over-repetitions limits of agreement. Face validity was demonstrated with significantly different walking speeds, step lengths and cadences over walking-speed conditions. To conclude, walking speed, step length, and cadence can be reliably and validly quantified from the position data of the wearable HoloLens 1 measurement system, not only for a broad range of speeds in healthy young adults, but also for self-selected comfortable speed in people with Parkinson’s disease.

17 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
BCBert Coolen
Bert Coolen
Peter BeekPeter Beek
Peter Beek
DGDaphne Geerse
Daphne Geerse
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
Mixed-reality technologies are evolving rapidly, allowing for gradually more realistic interaction with digital content while moving freely in real-world environments. In this study, we examined the suitability of the Microsoft HoloLens mixed-reality headset for creating locomotor interactions in real-world environments enriched with 3D holographic obstacles. In Experiment 1, we compared the obstacle-avoidance maneuvers of 12 participants stepping over either real or holographic obstacles of different heights and depths. Participants’ avoidance maneuvers were recorded with three spatially and temporally integrated Kinect v2 sensors. Similar to real obstacles, holographic obstacles elicited obstacle-avoidance maneuvers that scaled with obstacle dimensions. However, with holographic obstacles, some participants showed dissimilar trail or lead foot obstacle-avoidance maneuvers compared to real obstacles: they either consistently failed to raise their trail foot or crossed the obstacle with extreme lead-foot margins. In Experiment 2, we examined the efficacy of mixed-reality video feedback in altering such dissimilar avoidance maneuvers. Participants quickly adjusted their trail-foot crossing height and gradually lowered extreme lead-foot crossing heights in the course of mixed-reality video feedback trials, and these improvements were largely retained in subsequent trials without feedback. Participant-specific differences in real and holographic obstacle avoidance notwithstanding, the present results suggest that 3D holographic obstacles supplemented with mixed-reality video feedback may be used for studying and perhaps also training 3D obstacle avoidance.

10 January 2022 in Frontiers in Neurology
Verified
Journal Article
Open access
DGDaphne Geerse
Daphne Geerse
BCBert Coolen
Bert Coolen
JHJacobus J. van Hilten
Jacobus J. van Hilten
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
External visual cueing is a well-known means to target freezing of gait (FOG) in Parkinson's disease patients. Holocue is a wearable visual cueing application that allows the HoloLens 1 mixed-reality headset to present on-demand patient-tailored action-relevant 2D and 3D holographic visual cues in free-living environments. The aim of this study involving 24 Parkinson's disease patients with dopaminergic “ON state” FOG was two-fold. First, to explore unfamiliarity and habituation effects associated with wearing the HoloLens on FOG. Second, to evaluate the potential immediate effect of Holocue on alleviating FOG in the home environment. Three sessions were conducted to examine (1) the effect of wearing the unfamiliar HoloLens on FOG by comparing walking with and without the HoloLens, (2) habituation effects to wearing the HoloLens by comparing FOG while walking with HoloLens over sessions, and (3) the potential immediate effect of Holocue on FOG by comparing walking with HoloLens with and without Holocue. Wearing the HoloLens (without Holocue) did significantly increase the number and duration of FOG episodes, but this unfamiliarity effect disappeared with habituation over sessions. This not only emphasizes the need for sufficient habituation to unfamiliar devices, but also testifies to the need for research designs with appropriate control conditions when examining effects of unfamiliar wearable cueing devices. Holocue had overall no immediate effect on FOG, although objective and subjective benefits were observed for some individuals, most notably those with long and/or many FOG episodes. Our participants raised valuable opportunities to improve Holocue and confirmed our assumptions about current and anticipated future design choices, which supports ongoing Holocue development for and with end users.

12 December 2018 in Frontiers in Neurology
Verified
Journal Article
Open access
PDF file
DGDaphne Geerse
Daphne Geerse
MRMelvyn Roerdink
Melvyn Roerdink
JMJohan Marinus
Johan Marinus
JHJacobus J. van Hilten
Jacobus J. van Hilten
Introduction: In people with Parkinson's disease (PD) many aspects of walking ability deteriorate with advancing disease. Clinical tests typically evaluate single aspects of walking and to a lesser extent assess more complex walking tasks involving a combination of the three key aspects of walking ability (i.e., generating stepping, maintaining postural equilibrium, adapting walking). The Interactive Walkway allows for assessing more complex walking tasks to address features that are relevant for daily life walking of patients, including adaptive walking and dual-task walking. Methods: To evaluate the expected added value of Interactive Walkway assessments in people with PD, we first evaluated its known-groups validity for outcome measures of unconstrained walking, adaptive walking and dual-task walking. Subsequently, these outcome measures were related to commonly used clinical test scores. Finally, we evaluated the expected added value of these outcomes over clinical tests scores in discriminating people with PD with and without freezing of gait. Results: Interactive Walkway outcome measures showed significant differences between freezers, non-freezers and healthy controls, in expected directions. Most Interactive Walkway outcome measures were not or at best moderately correlated with clinical test scores. Finally, Interactive Walkway outcome measures of adaptive walking slightly better discriminated freezers from non-freezers than clinical tests scores. Conclusion: We confirmed the added value of Interactive Walkway assessments, which provides a comprehensive evaluation of walking ability incorporating features of its three key aspects. Future studies are warranted to examine the potential of the Interactive Walkway for the assessment of fall risk and informing on tailored falls prevention programs in people with PD and in other populations with impaired walking ability.