Cláudia Macedo

Dr. Cláudia Macedo


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2021 in GE - Portuguese Journal of Gastroenterology
Verified
Journal Article
Open access
PDF file
CMCláudia Macedo
Cláudia Macedo
MCMara Sarmento Costa
Mara Sarmento Costa
EGElisa Gravito-Soares
Elisa Gravito-Soares
MGMarta Gravito-Soares
Marta Gravito-Soares
AFAna Margarida Ferreira
Ana Margarida Ferreira
PFPedro Figueiredo
Pedro Figueiredo
Introduction: Endoscopy remains the exam of choice in the evaluation of activity in Crohn’s disease (CD) after surgery (ACD-AS). However, intestinal ultrasound (IUS) may represent a noninvasive alternative. The objective of this study is to determine the diagnostic accuracy of this modality compared to endoscopy. Material and Methods: This is a cross-sectional study, comprising a period of 14 months, carried out in patients with established CD and ileocecal resection due to the disease. IUS (HI-VISION Avius®, Tokyo, Japan) was performed with linear probe B-mode/Doppler prior to ileocolonoscopy. IUS and ileocolonoscopy were performed on the same day by 2 specialists in Gastroenterology dedicated to ultrasound and inflammatory bowel disease, in a double-blind mode. Collected demographic and clinical data (Harvey-Bradshaw Index [HBI]; remission ≤4), serological/fecal inflammatory parameters (leukocytes [4–10 × 109 cells/L], C-reactive protein [≤0.5 mg/dL], and fecal calprotectin [<50 mg/kg]), endoscopy (Rutgeerts score: remission Results: Thirty-nine patients (female: 64.1%, mean age: 43.5 ± 15.3 years) were included. The median post-surgery follow-up was 9 years (IQR 3–12). The Montreal classification was as follows: L1, 61.5% (n = 24); L3, 38.5% (n = 15); B1 and B2, 28.2% (n = 11); and B3, 43.6% (n = 17). Most patients were in clinical remission (87.2%; n = 34), with a mean HBI of 2.1 ± 2.2. Twenty-two patients (56.4%) had normal inflammatory markers. IUS (intestinal wall thickening >3 mm and/or Limberg score >1) was abnormal in 61.5% (n = 24) of the cases. Endoscopic remission (Rutgeerts score <i2) in 53.8% (n = 21) of the cases. Compared to endoscopy, IUS (area under the receiver operating characteristic curve [AUROC] = 0.75, p = 0.007) showed a diagnostic accuracy superior to that of inflammatory parameters (AUROC = 0.66, p = 0.083) and clinical parameters (AUROC = 0.64, p = 0.139). IUS showed a moderate concordance with endoscopy (κ = 0.5, p = 0.001), which was higher than that with inflammatory parameters (ĸ = 0.33, p = 0.041) or clinical parameters (ĸ = 0.29, p = 0.01). Conclusions: Ultrasound evaluation of the digestive wall is a noninvasive technique that shows a good diagnostic accuracy and a moderate concordance with endoscopy, being superior to clinical and serological/fecal inflammatory parameters.

7 October 2020 in GE - Portuguese Journal of Gastroenterology
Verified
Journal Article
Open access
PDF file
CMCláudia Macedo
Cláudia Macedo
NANuno Almeida
Nuno Almeida
AAAna Rita Alves
Ana Rita Alves
AFAna Margarida Ferreira
Ana Margarida Ferreira
PFPedro Figueiredo
Pedro Figueiredo
Introduction: Percutaneous endoscopic gastrostomy is a safe and effective technique and its use is widely spread. Peristomal leakage may occur within the first few days after gastrostomy tube placement and also in the mature gastrostomy tract. The initial treatment involves conservative measures. If the leakage does not resolve, different endoscopic interventions could be necessary with consequent impairing of enteral nutrition and, in some cases, the need of creating a new gastro-cutaneous fistula. Case Report: We present 4 consecutive cases complicated with late peristomal leakage and medical treatment failure. These patients underwent upper digestive endoscopy, and circumferential fulguration of the mucosa surrounding the tube with pulsed argon plasma coagulation (APC) at 50 W and 1 L/min flow rate was performed. Additional long through-the-scope clips were applied in 2 cases, since the inner orifice remained enlarged, in order to obtain a better closure. Complete leakage and skin changes resolution occurred between 2 and 6 weeks after the procedure (mean 3.5 weeks). The overall mean follow-up was 19 months after the endoscopic procedure (maximum 30 months, minimum 10 months). There was no recurrence of leakage. Conclusion: The use of APC alone or combined with long through-the-scope clips in large internal stoma orifice resolved persistent leakage from percutaneous endoscopic gastrostomy in all 4 presented cases without complications. In our case series, this technique appeared to be an effective, safe, and relatively low-cost alternative to the treatment of persistent peristomal leakage of the mature gastrostomy tract.

17 March 2023 in GE - Portuguese Journal of Gastroenterology
Verified
Journal Article
Open access
PDF file
CCCatarina Correia
Catarina Correia
NANuno Almeida
Nuno Almeida
RARaquel Andrade
Raquel Andrade
MSMariana Sant’aNna
Mariana Sant’aNna
CMCláudia Macedo
Cláudia Macedo
PFPedro Narra Figueiredo
Pedro Narra Figueiredo
Introduction: According to the guideline published by ESGE/UEG, a high-quality esophagogastroduodenoscopy (EGD) implies the application of some criteria that enable better healthcare outcomes. Although intra-procedural performance measures are dependent on patient factors, there is no reference to sedation practices in the guideline mentioned above. Objective: This study aimed to evaluate whether deep sedation influences EGD performance measures established by ESGE/UEG. Methods: This was a cross-sectional study, with a prospective enrollment, that considered for inclusion consecutive patients referred for EGD. Two questionnaires were used to assess performance measures and patient satisfaction after EGD. Results: Sedation had a statistically significant impact on most quality indicators, including complete examination (77.2% without sedation vs. 97.8% with sedation), inspection time (6.17 ± 3.45 vs. 8.39 ± 2.67 min), photodocumentation (78% vs. 97.8%), biopsies (39.3% vs. 60.7%), and patient satisfaction (5.42 ± 2.93 vs. 9.1 ± 1.19). The main reason for an incomplete procedure was patient intolerance (82.6%). Discussion: Deep sedation of patients submitted to EGD proved to be a determinant in the applicability of the ESGE/UEG quality indicators. Patient intolerance was eliminated in the group with sedation, enhancing procedure completeness, adequate pathology identification, management, and consequently, the effectiveness of the exam. Conclusion: Sedation administration should be considered in patients undergoing EGD since it ensures a high-quality procedure.

28 August 2025 in American Journal of Gastroenterology
Verified
Journal Article
Closed access
Miguel Mascarenhas SaraivaMiguel Mascarenhas Saraiva
Miguel Mascarenhas Saraiva
JFJ.P.S. Ferreira
J.P.S. Ferreira
JAJoão Afonso
João Afonso
FMFrancisco Mendes
Francisco Mendes
WSWilliam Preston Sonnier
William Preston Sonnier
Guilherme MacedoGuilherme Macedo
Guilherme Macedo
INTRODUCTION: Capsule endoscopy (CapE) is a minimally invasive procedure designed for small bowels' evaluation. However, prolonged reading times and a risk of missing clinically significant findings limit its potential. Prospective clinical validation studies of artificial intelligence (AI) for CapE remain scarce. Furthermore, existing studies focus on lesion detection, without addressing lesion differentiation. METHODS: The aim of a multicenter prospective validation study was to compare AI-assisted reading with conventional CapE reading. Three hundred thirty CapE videos from 3 devices across 7 centers and 4 countries were included. After conventional reading reports, AI-assisted reading was performed by an independent expert using a deep learning model to detect and differentiate pleomorphic small bowel lesions. Both reports were reviewed by an expert from an independent center, which decided in discrepant cases. AI-assisted and standard readings were evaluated through their accuracy, sensitivity, specificity, positive and negative predictive value, and small bowel lesion detection rate. RESULTS: AI-assisted reading detected 605 of 635 lesions identified by expert-based consensus, whereas standard reading identified 354 lesions. AI-assisted reading outperformed standard reading, with small bowel lesion detection rate of 96.1% vs 76.3% and sensitivity of 97.5% vs 78.2%. AI-assisted reading had a mean examination reading time of 203 seconds per examination. DISCUSSION: This was the first multicentric study proving AI-assisted CapE reading superiority compared with conventional reading. The inclusion of videos from multiple devices addresses the interoperability challenge, whereas including patients from 4 countries and 2 different continents assures a diverse demographic context. AI achieved gastroenterologist-level identification of small-bowel lesions, surpassing conventional reading methods in both lesion detection and characterization.

14 May 2020 in GE - Portuguese Journal of Gastroenterology
Verified
Journal Article
Open access
PDF file
CMCláudia Macedo
Cláudia Macedo
NANuno Almeida
Nuno Almeida
Endoscopia digestiva alta · Doença do refluxo gastroesofágico · Manifestações extra-esofágicas ·

3 August 2020 in Advances in Digestive Medicine
Verified
Journal Article
Open access
PDF file
CMCláudia Macedo
Cláudia Macedo
NANuno Almeida
Nuno Almeida
PFPedro Figueiredo
Pedro Figueiredo
Click on the article title to read more.