Cedric Schaack

Dr. Cedric Schaack

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2023 in Chemical Science
Verified
Journal Article
Open access
PDF file
BZBoyuan Zhang
Boyuan Zhang
CSCedric Schaack
Cedric Schaack
CPClaudia R. Prindle
Claudia R. Prindle
EVEthan A. Vo
Ethan A. Vo
MAMiriam Aziz
Miriam Aziz
LVLatha Venkataraman
Latha Venkataraman
We demonstrate that electric fields can homolytically cleave a peroxide bond in different solvents with a rate that is proportional to the solvent dielectric constant.

16 January 2025 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
SBSummer J. Brown
Summer J. Brown
JZJiaoyan Zhao
Jiaoyan Zhao
EFEllen Forehand
Ellen Forehand
LDLukasz Dobrzycki
Lukasz Dobrzycki
RRRupam Roy
Rupam Roy
AEAustin M. Evans
Austin M. Evans

24 September 2024 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
MAMiriam Aziz
Miriam Aziz
CPClaudia R. Prindle
Claudia R. Prindle
WLWoojung Lee
Woojung Lee
BZBoyuan Zhang
Boyuan Zhang
CSCedric Schaack
Cedric Schaack
LVLatha Venkataraman
Latha Venkataraman

25 August 2025 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
JZJiaoyan Zhao
Jiaoyan Zhao
LJLin Jiao
Lin Jiao
LKLilia Kinziabulatova
Lilia Kinziabulatova
TWTyler J. Williams
Tyler J. Williams
RGRebecca M. Gracia
Rebecca M. Gracia
CSCedric Schaack
Cedric Schaack

4 November 2025 in Microplastics
Verified
Journal Article
Open access
PDF file
CBCharles Edward Bardawil
Charles Edward Bardawil
JDJarrett Dobbins
Jarrett Dobbins
SLShannon Lankford
Shannon Lankford
SCSaif Chowdrey
Saif Chowdrey
JSJack Shumway
Jack Shumway
RDRajeev Dhupar
Rajeev Dhupar
Microplastics (MPs) are synthetic environmental pollutants increasingly linked to adverse human health effects. To study their biological impact, researchers require access to environmentally relevant MPs that can be accurately tracked in biological systems. However, most ambient MPs are composed of non-conjugated polymers that lack intrinsic fluorescence, limiting their utility in live-cell or in vivo imaging. Addressing this challenge, we present two alternative labeling approaches that enable visualization, tracking, and quantification of MPs. First, we stained nylon and polypropylene MPs with Rhodamine 6G, a fluorescent dye known for its stability and compatibility with in vivo applications. These labeled MPs retained strong fluorescence in murine lung tissue for up to one week, as confirmed by fluorescent microscopy. Second, we conjugated aminated polystyrene microspheres with IRDye-800CW, a near-infrared fluorophore that enables high-resolution imaging with minimal tissue autofluorescence via an In Vivo Imaging System and confocal microscopy. In vivo experiments revealed organ-specific accumulation of IRDye-labeled MPs, with a 2.8-fold increase in the liver and a 5-fold increase in spleen compared to controls, detectable up to 72 h post-injection. These labeling strategies provide researchers with practical tools to visualize and study the biodistribution of MPs in biological systems, advancing efforts to understand their health implications.

30 September 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
CBCharles Edward Bardawil
Charles Edward Bardawil
JDJarrett Dobbins
Jarrett Dobbins
SLShannon Lankford
Shannon Lankford
SCSaif Chowdrey
Saif Chowdrey
JSJack Shumway
Jack Shumway
RDRajeev Dhupar
Rajeev Dhupar
Microplastics (MPs) are synthetic environmental pollutants increasingly linked to adverse human health effects. To study their biological impact, researchers require access to environmentally relevant MPs that can be accurately tracked in biological systems. However, most ambient MPs are composed of non-conjugated polymers that lack intrinsic fluorescence, limiting their utility in live-cell or in vivo imaging. To address this challenge, we present two alternative labeling approaches that enable visualization, distribution tracking, and quantification of MPs. First, we stained nylon and polypropylene MPs with Rhodamine 6G, a fluorescent dye known for its stability and compatibility with in vivo applications. These labeled MPs retained strong fluorescence in murine lung tissue for up to one week, as confirmed by fluorescent microscopy. Second, we conjugated aminated polystyrene microspheres with IRDye 800CW, a near-infrared fluorophore that reduces tissue autofluorescence and enables high-resolution imaging via IVIS and confocal microscopy. In vivo experiments revealed organ-specific accumulation of IRDye-labeled MPs, with a 2.8-fold increase in the liver and a 5-fold increase in the spleen compared to controls, detectable up to 72 hours post-injection. These labeling strategies provide re-searchers with practical tools to visualize and study the biodistribution of MPs in biological systems, advancing efforts to understand their health implications.