C. pseudotuberculosis is a Gram-positive pathogenic bacterium that infects various animals, causing diseases such as caseous lymphadenitis, leading to significant economic losses in the livestock industry and posing zoonotic risks. This study targeted the conserved gyrA gene fragment of this bacterium, designed specific primers, optimized the reaction system and conditions, and established a high-resolution melting curve (HRM) detection method with potential utility for preliminary molecular screening. Validation showed that this method exhibits strong specificity, producing specific amplification only for the target biovars. The melting temperatures (Tm values) for the two biovars were 86.16 ± 0.05 °C and 86.92 ± 0.05 °C, respectively, allowing clear differentiation. It demonstrated high sensitivity, with minimum detection limits of 28 copies/μL and 25 copies/μL for standard plasmids of the ovis and equi biovars, respectively. The method also showed good reproducibility, with intra- and inter-batch coefficients of variation both below 1.0%. Applied to 133 clinical nasal swab samples from goats in Fujian Province, the method detected a positivity rate of 19.5% and indicates that a biovar equi-like gene fragment was detected in goat nasal swabs from Fujian Province via molecular screening. The HRM method developed in this study is sensitive, specific, simple, and cost-effective, enabling rapid detection and biovar differentiation of C. pseudotuberculosis. It is suitable for large-scale clinical sample screening and provides an efficient technical approach for epidemiological monitoring and precise control of the disease.
Caseous lymphadenitis (CLA), an infectious disease caused by Corynebacterium pseudotuberculosis (C. pseudotuberculosis), poses a significant economic burden to the global small ruminant industry. This study aimed to investigate genetic variations in the CP40 gene of C. pseudotuberculosis and to develop a rapid detection assay for enhanced pathogen identification. Homology analysis was performed to compare the CP40 gene sequence of the FJ-PN strain with other Corynebacterium species. Specific primers targeting CP40 were designed, and a SYBR Green I-based real-time PCR protocol was optimized. The assay’s specificity, sensitivity, and reproducibility were subsequently validated. The FJ-PN strain exhibited ≥99.65% nucleotide identity and ≥98.94% amino acid identity with C. pseudotuberculosis biovar ovi reference strains, showing 90.18–91.84% nucleotide identity and 88.63–90.77% amino acid identity with C. pseudotuberculosis biovar equi, and ≤82.71% nucleotide identity and ≤78.63% amino acid identity with other Corynebacterium species. The established qPCR assay demonstrated high specificity, the limit of detection was 52 copies/μL, and it demonstrated good reproducibility (intra- and inter-assay CV < 1.0%). Clinical sample testing revealed 18.8% positivity rates in nasal swabs, which was higher than that detected by conventional PCR (16.3%). These results indicate that the CP40 gene is evolutionarily conserved and represents a specific molecular marker for the identification of C. pseudotuberculosis biovar ovis. The developed SYBR Green I real-time PCR assay enables the efficient detection of C. pseudotuberculosis and provides technical support for CLA surveillance and control.