Jorn B. Thomsen

Dr. Jorn B. Thomsen


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Archives of Plastic Surgery
Verified
Journal Article
Open access
PDF file
DDDiana Lydia Dyrberg
Diana Lydia Dyrberg
CBCamilla Bille
Camilla Bille
GGGudjon Leifur Gunnarsson
Gudjon Leifur Gunnarsson
TFTove Faber Frandsen
Tove Faber Frandsen
CSC. Andrew Salzberg
C. Andrew Salzberg
JTJorn B. Thomsen
Jorn B. Thomsen
Breast animation deformity (BAD) has been reported to occur after submuscular implant placement following breast augmentation and immediate breast reconstruction. Despite its apparent impact on patients’ quality of life, BAD has only recently become a topic of general concern. Its incidence and etiology have yet to be established. The aim of this systematic review was to identify papers that clearly defined and classified BAD and described how the degree of animation was assessed. We performed a search in PubMed and Embase. Studies meeting the inclusion criteria that described BAD after implant-based breast augmentation or immediate breast reconstruction were included. After screening 866 publications, four studies were included: three describing BAD after breast augmentation and one describing BAD after immediate breast reconstruction. The median percentage of patients with some degree of BAD was 58%. The highest percentages were found in patients operated on using the Regnault technique or the dual-plane technique (73%–78%). The lowest percentages were found following the dual-plane muscle-splitting technique (30%) and the triple-plane technique (33%). We found no studies meeting the inclusion criteria that analyzed BAD after prepectoral implant placement. This review of the current literature suggests that the degree of BAD is proportional to the degree of muscle involvement. Evidence is scarce, and the phenomenon seems to be underreported. Future comparative studies are warranted.

1 December 2019 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
MRMikkel Børsen Rindom
Mikkel Børsen Rindom
GGGudjon L. Gunnarsson
Gudjon L. Gunnarsson
MLMarianne D. Lautrup
Marianne D. Lautrup
RCRené D. Christensen
René D. Christensen
TTTina Tos
Tina Tos
JTJorn B. Thomsen
Jorn B. Thomsen

26 March 2021 in Cancers
Verified
Journal Article
Open access
PDF file
MJMads Gustaf Jørgensen
Mads Gustaf Jørgensen
NTNavid Mohamadpour Toyserkani
Navid Mohamadpour Toyserkani
FHFrederik Christopher Gulmark Hansen
Frederik Christopher Gulmark Hansen
JTJorn B. Thomsen
Jorn B. Thomsen
JSJens Ahm Sørensen
Jens Ahm Sørensen
Indocyanine green lymphangiography (ICG-L) allows real-time investigation of lymphatics. Plastic surgeons performing lymphatic reconstruction use the ICG-L for patient selection and stratification using the MD Anderson (MDA) and the Arm Dermal Backflow (ADB) grading systems. However, the applicability of ICG-L in evaluating breast cancer-related lymphedema (BCRL) is sparse and not well established. This study comprehensively examines the usability of ICG-L in the assessment of BCRL. We prospectively performed ICG-L in 237 BCRL patients between January 2019 and February 2020. The aim of this study was to assess the interrater and intrarater agreement and interscale consensus of ratings made using the MDA and ADB scales. Three independent raters performed a total of 2607 ICG-L assessments. The ICG-L stage for each grading system was correlated to the lymphedema volume to assess the agreement between the ICG-L stage and clinical severity. The interrater agreement was near perfect for the MDA scale (kappa 0.82–0.90) and the ADB scale (kappa 0.80–0.91). Similarly, we found a near-perfect intrarater agreement for the MDA scale (kappa 0.84–0.94) and the ADB scale (kappa 0.88–0.89). The agreement between the MDA and the ADB scales was substantial (kappa 0.65–0.68); however, the ADB scale systematically overestimated lower ICG-L stages compared to the MDA scale. The volume of lymphedema correlated slightly with MDA stage (Spearmans rho = 0.44, p < 0.001) and ADB stage (rs = 0.35, p < 0.001). No serious adverse events occurred. The staging of BCRL with ICG-L is reliable, safe, and provides unique disease information unobtainable with clinical measurements alone. The MDA scale seems to provide better disease stratification compared to the ADB scale.

1 November 2020 in Annals of Translational Medicine
Verified
Journal Article
Open access
PDF file
YLYunzhu Li
Yunzhu Li
XWXiaojun Wang
Xiaojun Wang
JTJorn B. Thomsen
Jorn B. Thomsen
MNMaurice Y. Nahabedian
Maurice Y. Nahabedian
NINaohiro Ishii
Naohiro Ishii
Yuh-Shan HoYuh-Shan Ho
Yuh-Shan Ho
Background: The need for postmastectomy breast reconstruction surgery has increased dramatically, and significant progress has been made both in implant and autologous based breast reconstruction in recent decades. In this paper, we performed a bibliometric analysis with the aim of providing an overview of the developments in breast reconstruction research and insight into the research trends. Methods: We searched the Science Citation Index Expanded database and the Web of Science Core Collection for articles published between 1991 to 2018 in the topic domain, using title, abstract, author keywords, and KeyWords Plus. Four citation indicators TCyear, Cyear, C0 and CPPyear were employed to help analyse the identified articles. Results: The number of scientific articles in breast reconstruction in this period steadily increased. It took most articles nearly a decade to hit a plateau in terms of citation counts. Plastic and Reconstructive Surgery, Annals of Plastic Surgery, and Journal of Plastic Reconstructive and Aesthetic Surgery published the largest number of articles on breast reconstruction. Nine of the top ten most prolific publications were based in the USA. The research highlights related to breast reconstruction were implant-based breast reconstruction, deep inferior epigastric perforator (DIEP) flap breast reconstruction, and superficial inferior epigastric artery (SIEA) flap breast reconstruction. Conclusions: This bibliometric analysis yielded data on citation number, publication outputs, categories, journals, institutions, countries, research highlights and tendencies. It helps to picture the panorama of breast reconstruction research, and guide the future research work.

1 January 2021 in Archives of Plastic Surgery
Verified
Journal Article
Open access
PDF file
JTJorn B. Thomsen
Jorn B. Thomsen
MRMikkel Børsen Rindom
Mikkel Børsen Rindom
ARAlberto Rancati
Alberto Rancati
CAClaudio Angrigiani
Claudio Angrigiani
Thoracodorsal artery (TDA) flaps, ranging from the vascular-pedicled thoracodorsal artery perforator (TDAP) flap, the propeller TDAP flap, and the muscle-sparing latissimus dorsi (MSLD) flap to the conventional latissimus dorsi (LD) flap and the extended LD flap, can all be used for breast reconstruction. The aim of this paper and review is to share our experiences and recommendations for procedure selection when applying TDA-based flaps for breast reconstruction. We describe the different surgical techniques and our thoughts and experience regarding indications and selection between these procedures for individual patients who opt for breast reconstruction. We have performed 574 TDA flaps in 491 patients: 60 extended LD flaps, 122 conventional LD flaps, two MSLD flaps, 233 propeller TDAP flaps, 122 TDAP flaps, and 35 free contralateral TDAP flaps for stacked TDAP breast reconstruction. All the TDA flaps are important flaps for reconstruction of the breast. The LD flap is still an option, although we prefer flaps without muscle when possible. The vascular-pedicled TDAP flap is an option for experienced surgeons, and the propeller TDAP flap can be used in most reconstructive cases of the breast, although a secondary procedure is often necessary for correction of the pedicle bulk. The extended LD flap is an option for women with a substantial body mass index, although it is associated with the highest morbidity of all the TDA flaps. The MSLD flap can be used if the perforators are small or if dissection of the perforators is assessed to be hazardous.

21 December 2014 in European Journal of Plastic Surgery
Verified
Journal Article
Open access
PDF file
GGGudjon Leifur Gunnarsson
Gudjon Leifur Gunnarsson
IJIan T. Jackson
Ian T. Jackson
TWTormod S. Westvik
Tormod S. Westvik
JTJorn B. Thomsen
Jorn B. Thomsen
Background Perforating vessels are a consistent anatomical finding and well described in the current literature. Any skin flap can be raised on a subcutaneous pedicle as long as it contains at least one supplying perforator. Perforator flaps have been interlinked with microsurgery and generally not widely performed by the general plastic surgeons. The aim of this paper is to present the simplicity of pedicled perforator flap reconstruction of moderate-sized defects of the extremities and torso. Methods We retrospectively reviewed the charts of 34 patients reconstructed using 34 freestyle pedicled perforator flaps for moderate-sized defects of the truncus and extremities. We registered indications, flap size and localization, success rate, and complications. Most importantly, we describe a simple approach to the design of freestyle pedicled perforator flaps and elaborate on technical aspects in the context of current literature. Results The reconstructive goals were achieved in all cases without any total flap loss or major complications. Minor complications occurred in 7/34 (21 %) cases consisting of venous congestion leading to distal tip necrosis or epidermolysis; partial flap loss was significant in 4 cases, however never more than 10 % of the total flap size. Reconstruction was performed on the lower limb in 13 cases, upper limb in 12, and 9 cases were on the truncus. The angle of rotation was 90° in 21 cases and 180° in 13 cases. The most common indication was reconstruction of oncological skin defects; melanoma 19, BCC 6, SCC 2, other 7. The flap size varied from 1.5×3 cm to 12×22 cm. The perforator identification was done by intraoperative exploration in 17 cases and by color Doppler ultrasonography in 17 cases. Conclusions Moderate-sized defects of the torso and extremities can be successfully reconstructed by pedicled perforator flaps. The flap dissection is simple, and the complication rates comparable to other reconstructive options. Level of evidence IV, therapeutic study