The formation mechanism and breakup process of droplets in a T-junction microchannel are illustrated by analyzing the dynamic behavior and driving forces. The changes in the pressure in the microchannel during the four stages of droplet breakup and the effects of the capillary number are obtained. The driving force model of the droplet breakup is obtained by analyzing the magnitude and position of the forces acting on the emerging droplets. Furthermore, the governing equations of the droplet breakup and predictive equations for the equivalent length and generation frequency of the droplet are obtained. The influences of the capillary numbers of the continuous phase, the viscosity ratio, the flow ratio, and the channel size on the droplet generation parameters are analyzed. To verify the predictive formula of the equivalent length of a droplet, the effects of the capillary number and viscosity ratio on the droplet length and frequency are determined. The theoretical analysis and experimental results indicate that the droplet length is inversely proportional to the capillary number and directly proportional to the flow rate ratio and the viscosity ratio. The influence of the flow rate ratio is greater than that of the viscosity ratio. The wall affects the droplet formation and the shape of the droplets but does not affect the size of the droplets.
Voltage sensing technology is crucial in realizing distributed voltage sensing at critical nodes of the power grid and providing key state variables to provide information support for control decisions. Among the existing voltage measurement methods, voltage transformers have problems such as high insulation performance requirements and limited installation locations. However, non-contact voltage sensors designed based on the electric field coupling principle have sensor accuracy problems due to the instability of the coupling capacitance. Based on the above problems, this paper first proposes a floating ground measurement system based on an equipotential and differential structure. It also proposes a dual capacitance equivalent model for AC voltage measurement on transmission lines. Based on this method, a calibration method for the amplitude and phase of the sensor is built. Under the voltage test at 50 Hz operating frequency in the voltage range (100–300 V), the maximum relative error of the voltage amplitude is 0.89%, and the maximum relative error of the voltage phase is 0.68°. The maximum relative error of voltage amplitude under a 50 Hz operating frequency voltage test in the voltage range (600 V–10 kV) is 4.48%. In the final scenario adaptation analysis, the method’s specific height amplitude accuracy error was experimentally verified to be 0.88%, with a maximum difference of 0.52% for multi-type conductor testing.