28 January 2025 in Circulation
Verified
Journal Article
Open access
PFPaul Friedman
Paul Friedman
FMFrancis Murgatroyd
Francis Murgatroyd
LBLucas V.A. Boersma
Lucas V.A. Boersma
JMJaimie Manlucu
Jaimie Manlucu
BKBradley P. Knight
Bradley P. Knight
OIon behalf of the Extravascular ICD Pivotal Study Investigators
on behalf of the Extravascular ICD Pivotal Study Investigators
BACKGROUND: Substernal lead placement of the extravascular implantable cardioverter defibrillator (EV ICD) permits both defibrillation at thresholds similar to those seen with transvenous implantable cardioverter defibrillators and effective anti-tachycardia pacing (ATP) while avoiding the vasculature and associated complications. The global Pivotal study has shown the EV ICD system to be safe and effective through 6 months, but long-term experience has yet to be published. Our aim was to report the performance and safety of the EV ICD system throughout the study. METHODS: The EV ICD Pivotal study was a prospective, global, single-arm, premarket clinical study. Individuals with a Class I or IIa indication for a single-chamber implantable cardioverter defibrillator per guidelines were enrolled. Freedom from major system- or procedure-related complications and appropriate and inappropriate therapy rates were assessed through 3 years with the Kaplan-Meier method. ATP success was calculated from simple proportions. RESULTS: An implantation was attempted in 316 patients (25.3% female; 53.8±13.1 years of age; 81.6% primary prevention; left ventricular ejection fraction, 38.9±15.4%). Of 299 patients with a successful implantation, 24 experienced 82 spontaneous arrhythmic episodes that were appropriately treated with ATP only (38, 46.3%), shock only (34, 41.5%), or both (10, 12.2%) for a Kaplan-Meier–estimated rate of first any appropriate therapy of 9.2% at 3 years. ATP was successful in 77.1% (37/48) of episodes, and ATP use significantly increased from discharge to last follow-up visit ( P <0.0001). Shock therapy was successful in 100% (27/27) of discrete, spontaneous ventricular arrhythmias. The inappropriate shock rates at 1 and 3 years were 9.8% and 17.5%, respectively, with P-wave oversensing the predominant cause. No major intraprocedural complications were reported, and the estimated freedom from system- or procedure-related major complications was 91.9% at 1 year and 89.0% at 3 years. The most common major complications were lead dislodgement (10 events; n=9 patients, 2.8%), postoperative wound or device pocket infection (n=8, 2.5%), and device inappropriate shock delivery (n=4, 1.3%). Twenty-four system revisions were performed as a result of major complications related to the EV ICD system or procedure. CONCLUSIONS: From implantation to study completion, the EV ICD Pivotal study demonstrated that a single integrated system with an extravascular lead placed in the substernal space maintains high ATP success, effective defibrillation, and a consistent safety profile. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04060680.

28 April 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MSMaciej Sterliński
Maciej Sterliński
ASAdam Sokal
Adam Sokal
RLRadoslaw K Lenarczyk
Radoslaw K Lenarczyk
FHFrederic Van Heuverswyn
Frederic Van Heuverswyn
CRC. Aldo Rinaldi
C. Aldo Rinaldi
RCRichard Cornelussen
Richard Cornelussen
Recent efforts to increase CRT response by multiSPOT pacing (MSP) from multiple bipols on the same left ventricular lead are still inconclusive. The Left Ventricular (LV) MultiSPOTpacing for CRT (iSPOT) study compared the acute hemodynamic response of MSP pacing by using 3 electrodes on a quadripolar lead compared with conventional biventricular pacing (BiV). Patients with left bundle branch block (LBBB) underwent an acute hemodynamic study to determine the %change in LV+dP/dtmax from baseline atrial pacing compared to the following configurations: BiV pacing with the LV lead in a one of lateral veins, while pacing from the distal, mid, or proximal electrode and all 3 electrodes together (i.e. MSP). All measurements were repeated 4 times at 5 different atrioventricular delays. We also measured QRS-width and individual Q-LV durations. Protocol was completed in 24 patients, all with LBBB (QRS width 171±20 ms) and 58% ischemic aetiology. The percentage change in LV+dP/dtmax for MSP pacing was 31.0±3.3% (Mean±SE), which was not significantly superior to any BiV pacing configuration: 28.9±3.2% (LV-distal), 28.3±2.7% (LV-mid), and 29.5±3.0% (LV-prox), respectively. Correlation between LV+dP/dtmax and either QRS-width or Q-LV ratio was poor. In patients with LBBB MultiSPOT LV pacing demonstrated comparable improvement in contractility to best conventional BiV pacing. Optimization of atrioventricular delay is important for the best performance for both BiV and MultiSPOT pacing configurations. ClinicalTrials.gov NTC01883141

27 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
EŚEwa Świerżyńska
Ewa Świerżyńska
AOArtur Oreziak
Artur Oreziak
RGRenata Główczyńska
Renata Główczyńska
ARAntonio Rossillo
Antonio Rossillo
MGMarcin Grabowski
Marcin Grabowski
MSMaciej Sterliński
Maciej Sterliński
Modern cardiac pacemakers are equipped with a function that allows the heart rate to adapt to the current needs of the patient in situations of increased demand related to exercise and stress ("rate-response" function). This function may be based on a variety of mechanisms, such as a built-in accelerometer responding to increased chest movement or algorithms sensing metabolic demand for oxygen, analysis of intrathoracic impedance, and analysis of the heart rhythm (Q-T interval). The latest technologies in the field of rate-response functionality relate to the use of an accelerometer in leadless endocavitary pacemakers; in these devices, the accelerometer enables mapping of the mechanical wave of the heart’s work cycle, enabling the pacemaker to correctly sense native impulses and stimulate the ventricles in synchrony with the cycles of atria and heart valves. Another modern system for synchronizing pacing rate with the patient’s real-time needs requires a closed-loop system that continuously monitors changes in the dynamics of heart contractions. This article discusses the technical details of various solutions for detecting and responding to situations related to increased oxygen demand (e.g., exercise or stress) in implantable pacemakers, and reviews the results of clinical trials regarding the use of these algorithms.

1 June 2018 in EuroIntervention
Verified
Journal Article
Closed access
MSMaciej Sterliński
Maciej Sterliński
MDMarcin Demkow
Marcin Demkow
KPKarolina Plaskota
Karolina Plaskota
AOArtur Oręziak
Artur Oręziak

28 November 2019 in Advances in Clinical and Experimental Medicine
Verified
Journal Article
Open access
AWArkadiusz Wejnarski
Arkadiusz Wejnarski
Piotr LeszczyńskiPiotr Leszczyński
Piotr Leszczyński
SŚStanisław Świeżewski
Stanisław Świeżewski
MPMarcin Podgórski
Marcin Podgórski
MFMichal Miroslaw Farkowski
Michal Miroslaw Farkowski
Robert GałązkowskiRobert Gałązkowski
Robert Gałązkowski
Patients with acute myocardial infarction (AMI) or acute trauma (AT) are transported by air to save time. Helicopter Emergency Medical Service (HEMS) provides both flights to and from the emergency scene, as well as interhospital transport (interHtransport). The objective of this study was to compare aeromedical transport and HEMS missions of AMI and AT patients regarding safety, medical procedures and the length of flights. This is a case-control study analyzing the medical history records of AMI and AT patients transported between hospitals and from the scene identified using ICD-10 codes. Research of customary data (age, sex and general health status measured with Glasgow Coma Scale (GCS) and Revised Trauma Score (RTS)) was performed. There were 48,555 flights in the years 2011-2016, of which 7,645 (15.7%) were interhospital (19% AMI and 12% AT). Out of these, 40,910 (84.3%) HEMS missions were to patients on the scene (10% AMI and 13% AT). No fatalities were noted. The AMI GCS score was higher than in AT patients: 15.0 vs 14.0, respectively. The medical procedures during transport of AMI patients between hospitals and from the scene were the following: cardiopulmonary resuscitation (CPR): 6 vs 73 cases (p < 0.001); oxygen therapy: 41.1% vs 50.2%, respectively. The median distance was 59.4 km vs 52.1 km (p < 0.001), while median flight time was 45.0 min vs 38.0 min (p < 0.001), respectively. Regarding AT patients, the procedures performed (during interhospital and from the scene transport) were the following: CPR: 5 vs 244 cases (p < 0.001); intubation: 10.7% vs 17.3% (p < 0.001); sedation: 50.1% vs 24.3% (p < 0.001); oxygen therapy: 17.6% vs 36.6% (p < 0.001); spinal board: 17.1% vs 66% (p < 0.001); cervical collar: 15.9% vs 63.4% (p < 0.001), respectively. Interhospital transport and HEMS mission median flight distance was 135.9 km vs 56.3 km (p < 0.001), while median flight time was 66.0 min vs 45.0 min (p < 0.001), respectively. Aeromedical transport is safe and very rarely requires resuscitation during the flight. The long distances of flights and time required can reflect the scarcity of trauma centers (TCs) compared to cardiovascular wards. The location of hemodynamic centers in Poland is optimal.
1

28 June 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
MSMaciej Sterliński
Maciej Sterliński
KBKarina V Bunting
Karina V Bunting
Giuseppe BorianiGiuseppe Boriani
Giuseppe Boriani
SBSerge Boveda
Serge Boveda
EGEduard Guasch
Eduard Guasch
DKDipak Kotecha
Dipak Kotecha
The aim is to describe the rationale, design, delivery, and baseline characteristics of the Stroke prevention and rhythm control Treatment: Evaluation of an Educational programme of the European society of cardiology in a cluster-Randomized trial in patients with Atrial Fibrillation (STEEER-AF) trial. STEEER-AF is a pragmatic trial designed to objectively and robustly determine whether guidelines are adhered to in routine practice and evaluate a targeted educational programme for healthcare professionals. Seventy centres were randomized in six countries (France, Germany, Italy, Poland, Spain, and UK; 2022–23). The STEEER-AF centres recruited 1732 patients with a diagnosis of atrial fibrillation (AF), with a mean age of 68.9 years (SD 11.7), CHA2DS2-VASc score of 3.2 (SD 1.8), and 647 (37%) women. Eight hundred and forty-three patients (49%) were in AF at enrolment and 760 (44%) in sinus rhythm. Oral anticoagulant therapy was prescribed in 1543 patients (89%), with the majority receiving direct oral anticoagulants (1378; 89%). Previous cardioversion, antiarrhythmic drug therapy, or ablation was recorded in 836 patients (48.3%). Five hundred fifty-one patients (31.8%) were currently receiving an antiarrhythmic drug, and 446 (25.8%) were scheduled to receive a future cardioversion or ablation. The educational programme engaged 195 healthcare professionals across centres randomized to the intervention group, consisting of bespoke interactive online learning and reinforcement activities, supported by national expert trainers. The STEEER-AF trial was successfully deployed across six European countries to investigate guideline adherence in real-world practice and evaluate if a structured educational programme for healthcare professionals can improve patient-level care. Clinicaltrials.gov, NCT04396418. The STEEER-AF trial in the context of the European Society of Cardiology roadmap for cardiovascular education (https://doi.org/10.1093/eurheartj/ehy058).11