Haider Butt

Dr. Haider Butt

School of Engineering, University of Birmingham, Birmingham, UK

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2016 in ACS Nano
Verified
Journal Article
Closed access
AYAli K. Yetisen
Ali K. Yetisen
HQHang Qu
Hang Qu
AMAmir Manbachi
Amir Manbachi
HBHaider Butt
Haider Butt
MDMehmet R. Dokmeci
Mehmet R. Dokmeci
SYSeok Hyun Yun
Seok Hyun Yun

11 June 2018 in Advanced Materials
Verified
Journal Article
Open access
PDF file
AYAli K. Yetisen
Ali K. Yetisen
JMJuan Leonardo Martinez‐Hurtado
Juan Leonardo Martinez‐Hurtado
BÜBarış Ünal
Barış Ünal
Ali  KhademhosseiniAli Khademhosseini
Ali Khademhosseini
HBHaider Butt
Haider Butt
Wearables as medical technologies are becoming an integral part of personal analytics, measuring physical status, recording physiological parameters, or informing schedule for medication. These continuously evolving technology platforms do not only promise to help people pursue a healthier life style, but also provide continuous medical data for actively tracking metabolic status, diagnosis, and treatment. Advances in the miniaturization of flexible electronics, electrochemical biosensors, microfluidics, and artificial intelligence algorithms have led to wearable devices that can generate real‐time medical data within the Internet of things. These flexible devices can be configured to make conformal contact with epidermal, ocular, intracochlear, and dental interfaces to collect biochemical or electrophysiological signals. This article discusses consumer trends in wearable electronics, commercial and emerging devices, and fabrication methods. It also reviews real‐time monitoring of vital signs using biosensors, stimuli‐responsive materials for drug delivery, and closed‐loop theranostic systems. It covers future challenges in augmented, virtual, and mixed reality, communication modes, energy management, displays, conformity, and data safety. The development of patient‐oriented wearable technologies and their incorporation in randomized clinical trials will facilitate the design of safe and effective approaches.

1 May 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Rifat Ahmmed AoniRifat Ahmmed Aoni
Rifat Ahmmed Aoni
RARajib Ahmed
Rajib Ahmed
AYAli K. Yetisen
Ali K. Yetisen
HBHaider Butt
Haider Butt
ASAydin Sabouri
Aydin Sabouri
FAF.R. Mahamd Adikan
F.R. Mahamd Adikan

11 May 2018 in ACS Nano
Verified
Journal Article
Open access
MEMohamed Elsherif
Mohamed Elsherif
MHMohammed Umair Hassan
Mohammed Umair Hassan
AYAli K. Yetisen
Ali K. Yetisen
HBHaider Butt
Haider Butt
Low-cost, robust, and reusable continuous glucose monitoring systems that can provide quantitative measurements at point-of-care settings is an unmet medical need. Optical glucose sensors require complex and time-consuming fabrication process and their readouts are not practical for quantitative analyses. Here, a wearable contact lens optical sensor was created for the continuous quantification of glucose at physiological conditions, simplifying the fabrication process and facilitating smartphone readouts. A photonic microstructure having a periodicity of 1.6 µm was printed on a glucose-selective hydrogel film functionalized with phenylboronic acid. Upon binding with glucose, the microstructure volume swelled, which modulated the periodicity constant. The resulting change in a Bragg diffraction modulated the space between zero and first order spots. A correlation was established between the periodicity constant and glucose concentration within 0 50 mM. The sensitivity of the sensor was 12 nm mM-1 and the saturation response time was less than 30 min. The sensor was integrated with commercial contact lenses and utilized for continuous glucose monitoring using smartphone camera readouts. The reflected power of the first order diffraction was measured via a smartphone application and correlated to the glucose concentrations. A short response time of 3 s and a saturation time of 4 min was achieved in the continuous monitoring mode. Glucose-sensitive photonic microstructures may have applications in point-of-care continuous monitoring devices and diagnostics at home settings.

13 February 2017 in Advanced Materials
Verified
Journal Article
Open access
PDF file
AYAli K. Yetisen
Ali K. Yetisen
Nan JiangNan Jiang
Nan Jiang
AFAfsoon Fallahi
Afsoon Fallahi
YMYunuen Montelongo
Yunuen Montelongo
GRGuillermo U. Ruiz‐Esparza
Guillermo U. Ruiz‐Esparza
SYSeok‐Hyun Yun
Seok‐Hyun Yun
Hydrogel optical fibers are utilized for continuous glucose sensing in real time. The hydrogel fibers consist of poly(acrylamide-co-poly(ethylene glycol) diacrylate) cores functionalized with phenylboronic acid. The complexation of the phenylboronic acid and cis-diol groups of glucose enables reversible changes of the hydrogel fiber diameter. The analyses of light propagation loss allow for quantitative glucose measurements within the physiological range.

12 March 2018 in ACS Nano
Verified
Journal Article
Open access
MEMohamed Elsherif
Mohamed Elsherif
MHMohammed Umair Hassan
Mohammed Umair Hassan
AYAli K. Yetisen
Ali K. Yetisen
HBHaider Butt
Haider Butt
Phenylboronic acids (PBAs) have emerged as synthetic receptors that can reversibly bind to cis diols of glucose molecules. The incorporation of phenylboronic acids in hydrogels offer exclusive attributes as the binding process with glucose induces Donnan osmotic pressure resulting in volumetric changes in the matrix. However, their practical applications are hindered because of complex readout approaches and their time-consuming fabrication processes. Here, we demonstrate a microimprinting method to fabricate densely-packed concavities in phenylboronic acid functionalized hydrogel films. A microengineered optical diffuser structure was imprinted on a phenylboronic acid based cis-diol recognizing motif prepositioned in a hydrogel film. The diffuser structure engineered on the hydrogel was based on laser inscribed arrays of imperfect microlenses that focused the incoming light at different focal lengths and direction resulting in a diffused profile of light in transmission and reflection readout modes. The signature of the dimensional modulation was detected in terms of changing focal lengths of the microlenses due to the volumetric expansion of the hydrogel that altered the diffusion spectra and transmitted beam profile. The transmitted optical light spread and intensity through the sensor was measured to determine variation in glucose concentrations at physiological conditions. The sensor was integrated in a contact lens and placed over an artificial eye. Artificial stimulation of variation in glucose concentration allowed quantitative measurements using a smartphone’s photodiode. A smartphone app was utilized to convert the received light intensity to quantitative glucose concentration values. The developed sensing platform offers low cost, rapid fabrication, and easy detection scheme as compared to other optical sensing counterparts. The presented detection scheme may have applications in wearable real-time biomarker monitoring devices at point-of-care settings.