Boštjan Polajžer

Prof. Dr. Boštjan Polajžer

University of Maribor, Faculty of Electrical Engineering and Computer Science
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
Boštjan PolajžerBoštjan Polajžer
Boštjan Polajžer
GŠGorazd Štumberger
Gorazd Štumberger
DDDrago Dolinar
Drago Dolinar
This study proposes a method for detecting voltage‐sag sources, using only the measurements of line currents. Instantaneous symmetrical components are introduced for accommodating the transient nature of voltage sag events, where a magnitude and phase change in the instantaneous positive‐sequence current is used as a criterion. The proposed method is compared with conventional phasor‐based methods known from the literature. All the discussed methods for voltage sag source detection, both the already known and the proposed ones, were evaluated by applying extensive simulations, laboratory tests and field testing. When compared with the phasor‐based methods, the proposed method showed faster response, a higher degree of confidence and superior effectiveness, especially for transient voltage sag events in networks with distributed generation and active loads.

31 May 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Boštjan PolajžerBoštjan Polajžer
Boštjan Polajžer
MPMartin Petrun
Martin Petrun
Jozef RitonjaJozef Ritonja
Jozef Ritonja
This paper proposes a parametric, statistical model for adapting the load-frequency-control (LFC) target values that are used for a performance evaluation. These target values should be determined in such a way that the system frequency will be bounded within the target range. One way of bounding the system frequency is to bound the variations of the area-control error (ACE) by increasing the control activations. On the other hand, the frequency can also be bounded by mutual coordination of the control among the control areas, thus affecting the covariances between the ACEs. Existing models for determining the LFC target values do not consider the covariances between the ACEs. The proposed model incorporates, for each area individually, the estimated value of the covariances between the ACEs and is inherently frequency dependent. In this way appropriate shares are obtained for the target ACE ranges among the control areas. The extensive field measurements in the discussed control area confirm the advantages of the proposed model over existing models for a monthly and online estimation of the LFC target values.

11 November 2019 in IEEE Access
Verified
Journal Article
Open access
Boštjan PolajžerBoštjan Polajžer
Boštjan Polajžer
MPMatej Pintarič
Matej Pintarič
MRMiran Roser
Miran Roser
GŠGorazd Štumberger
Gorazd Štumberger
This paper proposes measures to improve the protection of MV distribution networks operating with feeders in a closed-loop arrangement. Bi-directional overcurrent relays (OCRs) are discussed, the selectivity of which is achieved through the timing coordination of their operation. The classic approach is formulated as a minimization of the operating times of all the OCRs. The proposed approach enhances the selectivity by considering the maximum operating time of substation OCRs and the unwanted trips of inloop OCRs. Moreover, the sensitivity is also increased by introducing an objective function that minimizes the pickup-current settings of all the OCRs together with their operating times. Furthermore, to fulfill the demanding requirements for operating times, variable penalties are introduced. Thus, the optimization procedure is forced towards the region with viable solutions for the optimization problem. Two variants of self-adaptive differential evolution have been used that both show better convergence when compared to the classic differential evolution. Moreover, ten mutation strategies were tested, where “rand/1/bin” showed the best results. A comparison with other methods for timing coordination shows that the proposed optimization results in a comparable value for the OCRs’ operating times. In order to further reduce the operating times, GOOSE communications between the OCRs are adopted. The proposed measures for improved protection operation are fully confirmed through dynamic simulations of the faults in the discussed 20-kV network. Moreover, the proposed protection design is already implemented and permanently operates in a 20-kV network with more than 5000 customers, whereas the field results show selective and reliable protection operation.

16 February 2022 in Electric Power Systems Research
Verified
Journal Article
Open access
YMYounes Mohammadi
Younes Mohammadi
RLRoberto Chouhy Leborgne
Roberto Chouhy Leborgne
Boštjan PolajžerBoštjan Polajžer
Boštjan Polajžer

24 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
Younes MohammadiYounes Mohammadi
Younes Mohammadi
Aleksey PaltsevAleksey Paltsev
Aleksey Paltsev
Boštjan PolajžerBoštjan Polajžer
Boštjan Polajžer
Seyed Mahdi MiraftabzadehSeyed Mahdi Miraftabzadeh
Seyed Mahdi Miraftabzadeh
Davood KhodadadDavood Khodadad
Davood Khodadad
This paper presents a comprehensive study of winter temperatures in Norway and northern Sweden, covering a period of 50 to 70 years. The analysis utilizes Singular Spectrum Analysis (SSA) to investigate temperature trends at six selected locations. The results demonstrate an overall long-term rise in temperatures, which can be attributed to global warming. However, when investigating variations in highest, lowest, and average temperatures for December, January, and February, 50% of the cases exhibit a significant decrease in recent years, indicating colder winters, especially in December. The study also explores the variations in Atlantic Meridional Overturning Circulation (AMOC) variations as a crucial climate factor over the last 15 years, estimating a possible 20% decrease/slowdown within the first half of the 21st century. Subsequently, the study investigates potential similarities between winter AMOC and winter temperatures in the mid to high latitudes over the chosen locations. Additionally, the study examines another important climatic index, the North Atlantic Oscillation (NAO), and explores possible similarities between the winter NAO index and winter temperatures. The findings reveal a moderate observed lagged correlation for AMOC-smoothed temperatures, particularly in December, along the coastal areas of Norway. Conversely, a stronger lagged correlation is observed between the winter NAO index and temperatures in northwest Sweden and coastal areas of Norway. Thus, NAO may influence both AMOC and winter temperatures (NAO drives both AMOC and temperatures). Furthermore, the paper investigates the impact of colder winters, whether caused by AMOC, NAO, or other factors like winds or sea ice changes, on electrical power and energy systems, highlighting potential challenges such as reduced electricity generation, increased electricity consumption, and the vulnerability of power grids to winter storms. The study concludes by emphasizing the importance of enhancing the knowledge of electrical engineering researchers regarding important climate indices, AMOC and NAO, the possible associations between them and winter temperatures, and addressing the challenges posed by the likelihood of colder winters in power systems.

25 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jozef RitonjaJozef Ritonja
Jozef Ritonja
Boštjan PolajžerBoštjan Polajžer
Boštjan Polajžer
New energy sources, storage facilities, power electronics devices, advanced and complex control concepts, economic operating doctrines, and cost-optimized construction and production of machines and equipment in power systems adversely affect small-signal stability associated with local oscillations. The objective of the article is to analyze local oscillations and the causes that affect them in order to reduce their negative impact. There are no recognized analyses of the oscillations of modern operating synchronous generators exposed to new conditions in power systems. The basic idea is to perform a numerical analysis of local oscillations of a large number of synchronous generators in the power system. The paper represents the local mode data obtained from a systematic analysis of synchronous generators in the Slovenian power system. Analyzed were 74 synchronous generators of the Slovenian power system, plus many additional synchronous generators for which data were accessible in references. The mathematical models convenient for the study of local oscillations are described first in the paper. Next, the influences of transmission lines, size of the synchronous generators, operating conditions, and control systems were investigated. The paper’s merit is the applicable rules that have been defined to help power plant operators avoid stability-problematic situations. Consequently, boundaries were estimated of the eigenvalues of local modes. Finally, experiments were performed with a laboratory-size synchronous generator to assess the regularity of the numerically obtained conclusions. The obtained results enable the prediction of local oscillations’ frequencies and dampings and will be useful in PSS planning.