Nicola Belcari

Prof. Nicola Belcari


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2017 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
ECEsther Ciarrocchi
Esther Ciarrocchi
NBNicola Belcari
Nicola Belcari
Cerenkov luminescence imaging (CLI) is a novel imaging modality to study charged particles with optical methods by detecting the Cerenkov luminescence produced in tissue. This paper first describes the physical processes that govern the production and transport in tissue of Cerenkov luminescence. The detectors used for CLI and their most relevant specifications to optimize the acquisition of the Cerenkov signal are then presented, and CLI is compared with the other optical imaging modalities sharing the same data acquisition and processing methods. Finally, the scientific work related to CLI and the applications for which CLI has been proposed are reviewed. The paper ends with some considerations about further perspectives for this novel imaging modality.

26 June 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DPDaniele Panetta
Daniele Panetta
NBNicola Belcari
Nicola Belcari
AGA Del Guerra
A Del Guerra
SMS Moehrs
S Moehrs
In this paper we present a new method for the determination of geometrical misalignments in cone-beam CT scanners, from the analysis of the projection data of a generic object. No a priori knowledge of the object shape and positioning is required. We show that a cost function, which depends on the misalignment parameters, can be defined using the projection data and that such a cost function has a local minimum in correspondence to the actual parameters of the system. Hence, the calibration of the scanner can be carried out by minimizing the cost function using standard optimization techniques. The method is developed for a particular class of 3D object functions, for which the redundancy of the fan beam sinogram in the transaxial midplane can be extended to cone-beam projection data, even at wide cone angles. The method has an approximated validity for objects which do not belong to that class; in that case, a suitable subset of the projection data can be selected in order to compute the cost function. We show by numerical simulations that our method is capable to determine with high accuracy the most critical misalignment parameters of the scanner, i.e., the transversal shift and the skew of the detector. Additionally, the detector slant can be determined. Other parameters such as the detector tilt, the longitudinal shift and the error in the source-detector distance cannot be determined with our method, as the proposed cost function has a very weak dependence on them. However, due to the negligible influence of these latter parameters in the reconstructed image quality, they can be kept fixed at estimated values in both calibration and reconstruction processes without compromising the final result. A trade-off between computational cost and calibration accuracy must be considered when choosing the data subset used for the computation of the cost function. Results on real data of a mouse femur as obtained with a small animal micro-CT are shown as well, proving the capability of the proposed calibration method. In principle, the method can be adapted to other cone-beam imaging modalities (e.g., single photon emission computed tomography).

12 November 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
SMSascha Moehrs
Sascha Moehrs
MDMichel Defrise
Michel Defrise
NBNicola Belcari
Nicola Belcari
AGAlberto Del Guerra
Alberto Del Guerra
ABAntonietta Bartoli
Antonietta Bartoli
GZGianluigi Zanetti
Gianluigi Zanetti
Iterative image reconstruction algorithms for positron emission tomography (PET) require a sophisticated system matrix (model) of the scanner. Our aim is to set up such a model offline for the YAP-(S)PET II small animal imaging tomograph in order to use it subsequently with standard ML-EM (maximum-likelihood expectation maximization) and OSEM (ordered subset expectation maximization) for fully three-dimensional image reconstruction. In general, the system model can be obtained analytically, via measurements or via Monte Carlo simulations. In this paper, we present the multi-ray method, which can be considered as a hybrid method to set up the system model offline. It incorporates accurate analytical (geometric) considerations as well as crystal depth and crystal scatter effects. At the same time, it has the potential to model seamlessly other physical aspects such as the positron range. The proposed method is based on multiple rays which are traced from/to the detector crystals through the image volume. Such a ray-tracing approach itself is not new; however, we derive a novel mathematical formulation of the approach and investigate the positioning of the integration (ray-end) points. First, we study single system matrix entries and show that the positioning and weighting of the ray-end points according to Gaussian integration give better results compared to equally spaced integration points (trapezoidal integration), especially if only a small number of integration points (rays) are used. Additionally, we show that, for a given variance of the single matrix entries, the number of rays (events) required to calculate the whole matrix is a factor of 20 larger when using a pure Monte-Carlo-based method. Finally, we analyse the quality of the model by reconstructing phantom data from the YAP-(S)PET II scanner.

28 August 2001 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
SLS. M. Lenzi
S. M. Lenzi
NMN. Mărginean
N. Mărginean
DNDaniel Ricardo Napoli
Daniel Ricardo Napoli
CUC. A. Ur
C. A. Ur
AZA. P. Zuker
A. P. Zuker
MWM. Weiszflog
M. Weiszflog
Gamma rays from the N=Z−2 nucleus 50Fe have been observed, establishing the rotational ground state band up to the state Jπ=11+ at 6.994 MeV excitation energy. The experimental Coulomb energy differences, obtained by comparison with the isobaric analog states in its mirror 50Cr, confirm the qualitative interpretation of the backbending patterns in terms of successive alignments of proton and neutron pairs. A quantitative agreement with experiment has been achieved by exact shell model calculations, incorporating the differences in radii along the yrast bands, and properly renormalizing the Coulomb matrix elements in the pf model space.

27 March 2006 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
DHD.J. Herbert
D.J. Herbert
VSV. Saveliev
V. Saveliev
NBNicola Belcari
Nicola Belcari
NDN. D'AScenzo
N. D'AScenzo
AGA. Del Guerra
A. Del Guerra
AGA. Golovin
A. Golovin
A new type of silicon device has been realized that has many properties comparable to, or better than, a conventional PMT (Photomultiplier Tube). This paper presents the first results of using these photodetectors in place of a PMT in the readout of scintillators for possible PET (Positron Emission Tomography) applications. This device, the Silicon Photomultiplier (SiPM), is effectively an avalanche photodiode operated in Geiger mode. In Geiger-mode detectors, a very large current signal is produced regardless of the size of the input, giving just logical rather than proportional information. However, the SiPM is subdivided into a large number (1440) of microcells that act as independent and virtually identical Geiger-mode photodiodes. The outputs of all these individual microcells are connected so that the total output signal is the sum of the signals from all of the microcells that were activated. In this way proportional information can be obtained. As a consequence of their design, these detectors have potentially very fast timing, high gain (105-106) at low bias voltage (~50 V), a high quantum efficiency (35% at 500 nm), excellent single photoelectron resolution and are cheap to manufacture. Here we present results obtained with this new photodetector when used with pulsed LED and scintillator pixels

2 December 2016 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
MBMaria Giuseppina Bisogni
Maria Giuseppina Bisogni
AAAndrea Attili
Andrea Attili
GBGiuseppe Battistoni
Giuseppe Battistoni
NBNicola Belcari
Nicola Belcari
NCNiccolo’ Camarlinghi
Niccolo’ Camarlinghi
RWRichard Wheadon
Richard Wheadon
The quality assurance of particle therapy treatment is a fundamental issue that can be addressed by developing reliable monitoring techniques and indicators of the treatment plan correctness. Among the available imaging techniques, positron emission tomography (PET) has long been investigated and then clinically applied to proton and carbon beams. In 2013, the Innovative Solutions for Dosimetry in Hadrontherapy (INSIDE) collaboration proposed an innovative bimodal imaging concept that combines an in-beam PET scanner with a tracking system for charged particle imaging. This paper presents the general architecture of the INSIDE project but focuses on the in-beam PET scanner that has been designed to reconstruct the particles range with millimetric resolution within a fraction of the dose delivered in a treatment of head and neck tumors. The in-beam PET scanner has been recently installed at the Italian National Center of Oncologic Hadrontherapy (CNAO) in Pavia, Italy, and the commissioning phase has just started. The results of the first beam test with clinical proton beams on phantoms clearly show the capability of the in-beam PET to operate during the irradiation delivery and to reconstruct on-line the beam-induced activity map. The accuracy in the activity distal fall-off determination is millimetric for therapeutic doses.