Background: Up to 10% of epidurals fail due to incorrect catheter placement. We describe a novel optical method to assist epidural catheter insertion in a porcine model. Methods: Optical emissions were tested on ex vivo tissues from porcine paravertebral tissues to identify optical reflective spectra. The wavelengths of 650 and 532 nm differentiated epidural space from the ligamentum flavum. We then used a hollow stylet that contained optical fibers to place epidural needles in anesthetized pigs. Real-time data were displayed on an oscilloscope and stored for analysis. A total of 50 punctures were done in four laboratory pigs. Data were expressed as mean +/- SD. Results: Paired t test shows significant optical differences between the epidural space and the ligamentum flavum at both 650 nm (P < 0.001) and 532 nm (P = 0.014). Mean magnitudes for 650 nm, 532 nm, and their ratio were 3.565 +/- 0.194, 2.542 +/- 0.145, and 0.958 +/- 0.172 at epidural space and 3.842 +/- 0.191, 2.563 +/- 0.131, and 1.228 +/- 0.244 at ligamentum flavum, respectively. There were no differences in the optical characteristics of the ligamentum flavum and epidural space at different levels in the lumbar and thoracic region (two-way ANOVA P > 0.05). Conclusions: This is the first study to introduce a new optical method to localize epidural space in a porcine model. Epidural space could be identified by the changes in the reflective pattern of light emitted at 650 nm, which were specific for the ligamentum flavum and dural tissue. Real-time optical information successfully guided a modified Tuohy needle into the epidural space.
Background: Epidural needle insertion is usually a blind technique where the rate of adverse events depends on the experience of the operator. A novel ultrasound method to guide epidural catheter insertion is described. Methods: An ultrasound transducer (40 MHz, a -6 dB fractional bandwidth of 50%) was placed into the hollow chamber of an 18-gauge Tuohy needle. The single crystal was polished to a thickness of 50 μm, with a width of 0.5 mm. Tissue planes were identified from the reflected signals in an A-mode display. The device was inserted three times into both the lumbar and thoracic regions of five pigs (average weight, 20 kg) using a paramedian approach at an angle of 35-40°. The epidural space was identified using signals from the ligamentum flavum and dura mater. Epidural catheters were placed with each attempt and placement confirmed by contrast injection. Results: The ligamentum flavum was identified in 83.3% of insertions and the dura mater in all insertions. The dura mater signal was stronger than that of the ligamentum flavum and served as a landmark in all epidural catheter insertions. Contrast studies confirmed correct placement of the catheter in the epidural space of all study animals. Conclusions: This is the first study to introduce a new ultrasound probe embedded in a standard epidural needle. It is anticipated that this technique could reduce failed epidural blocks and complications caused by dural puncture.
During sedated endoscopic examinations, upper airway obstruction occurs. Nasal breathing often shifts to oral breathing during open mouth esophagogastroduodenoscopy (EGD). High-flow nasal cannula (HFNC) which delivers humidified 100% oxygen at 30 L min−1 may prevent hypoxemia. A mandibular advancement (MA) bite block with oxygen inlet directed to both mouth and nose may prevent airway obstruction during sedated EGD. The purpose of this study was to evaluate the efficacy of these airway devices versus standard management. One hundred and eighty-nine patients were assessed for eligibility. One hundred and fifty-three were enrolled. This study randomly assigned eligible patients to three arms: the standard bite block and standard nasal cannula, HFNC, and MA bite block groups. EGD was performed after anaesthetic induction. The primary endpoint was the oxygen desaturation area under curve at 90% (). The secondary endpoints were percentage of patients with hypoxic, upper airway obstruction, and apnoeic and rescue events. One hundred and fifty-three patients were enrolled. AUCdesat was significantly lower for HFNC and MA bite blocks versus the standard management (p= 0.019). The HFNC reduced hypoxic events by 18% despite similar airway obstruction and apnoeic events as standard group. The MA bite block reduced hypoxic events by 12% and airway obstructions by 32%. The HFNC and MA groups both showed a 16% and 14% reduction in the number of patients who received rescue intervention, respectively, compared to the standard group. The HFNC and MA bite block may both reduce degree and duration of hypoxemia. HFNC may decrease hypoxemic events while maintaining nasal patency is crucial during sedative EGD. The MA bite block may prevent airway obstruction and decrease the need for rescue intervention.
An optical probe placed in the epidural needle coupled with swept-source optical coherence tomography can provide two-dimensional images of tissue surrounding the needle tip. Using a porcine model, high sensitivity and specificity for the identification of the epidural space were achieved. Background: Epidural needle insertion is traditionally a blind technique whose success depends on the experience of the operator. The authors describe a novel method using a fiber-needle–based swept-source optical coherence tomography (SSOCT) to identify epidural space. Methods: An optical fiber probe was placed into a hollow 18-gauge Tuohy needle. It was then inserted by an experienced anesthesiologist to continuously construct a series of two-dimensional SSOCT images by mechanically rotating the optical probe. To quantify this observation, both the average SSOCT signal intensities and their diagnostic potentials were assessed. The insertions were performed three times into both the lumbar and thoracic regions of five pigs using a paramedian approach. Results: A side-looking SSOCT is constructed to create a visual image of the underlying structures. The image criteria for the identification of the epidural space from the outside region were generated by the analysis of a training set (n = 100) of ex vivo data. The SSOCT image criteria for in vivo epidural space identification are high sensitivity (0.867 to 0.965) and high specificity (0.838 to 0.935). The mean value of the average signal intensities exhibits statistically significant differences (P < 0.01) and a high discriminatory capacity (area under curve = 0.88) between the epidural space and the outside tissues. Conclusions: This is the first study to introduce a SSOCT fiber probe embedded in a standard epidural needle. The authors anticipate that this technique will reduce the occurrence of failed epidural blocks and other complications such as dural punctures.
Patient-controlled epidural analgesia (PCEA) has been applied to reduce postoperative pain in orthopedic surgical patients. Unfortunately, PCEA is occasionally accompanied by nausea and vomiting. The logistic regression (LR) model is widely used to predict vomiting, and recently support vector machines (SVM), a supervised machine learning method, has been used for classification and prediction. Unlike our previous work which compared Artificial Neural Networks (ANNs) with LR, this study uses a SVM-based predictive model to identify patients with high risk of vomiting during PCEA and comparing results with those derived from the LR-based model. From January to March 2007, data from 195 patients undergoing PCEA following orthopedic surgery were applied to develop two predictive models. 75% of the data were randomly selected for training, while the remainder was used for testing to validate predictive performance. The area under curve (AUC) was measured using the Receiver Operating Characteristic curve (ROC). The area under ROC curves of LR and SVM models were 0.734 and 0.929, respectively. A computer-based predictive model can be used to identify those who are at high risk for vomiting after PCEA, allowing for patient-specific therapeutic intervention or the use of alternative analgesic methods.