The present study demonstrates a common behaviour of a forced nonlinear structure with smooth nonlinearity, while coupled dynamics are apparent, originating from the attached electrodynamic shaker. This appears as a variation in the transmitted forcing amplitude and is often subjected to a hysteretic (multi-state) behaviour for up and down open-loop sweeping. This situation differs from the ideal constant amplitude harmonic excitation, on which parameter extraction and engineering comprehension are based on. Untreated or ignored, this can lead to the misinterpretation of the underlying dynamics through the measured nonlinear frequency response curves and their force-normalised version, often called quasi-frequency response function. In this paper, a post-processing solution is introduced for the correct interpretation of frequency response curves at constant forcing amplitudes through the open-loop construction and resectioning of the so-called frequency response surface. The phenomenon and the proposed methodology are demonstrated using a two-degrees-of-freedom model on a shaker-nonlinear beam structure. First, open-loop frequency sweeps are executed on the mechanical system to create the nonlinear frequency response surface, where their actual amplitudes and hysteresis widths are significantly different from the ideal constant forcing amplitude case. The response surface is then sectioned at the assumed constant forcing values by using an appropriate interpolation law. These resectioned curves represent the forced nonlinear standalone structure under ideal constant harmonic excitation. The frequency response surfaces are characterised and resectioned on a nonlinear structure with stiffening and softening cases. Furthermore, an improvement in the operational resonance decay (ORD) method in its filtering and automation is shown to extract the backbone curves (BBCs). The BBC and the resectioned surface provide a complete picture and cross-validation of the underlying dynamics. Finally, the BBC and its distortion are also shown in the response surfaces in relation with the excitation normalization.
24 December 2022 in Journal of Sound and Vibration
This paper presents an integrated approach for extracting nonlinear frequency response (NLFR) curves in systems affected by shaker-structure interaction. The approach leverages three distinct phase-locked loop (PLL) testing methods, each tailored for different levels of coupling effects. By resectioning the response surfaces obtained from the proposed PLL-based tests, the need for force controllers is eliminated. The technique is validated through numerical and experimental studies. Experiments conducted on nonlinear beam and plate structures illustrate the effectiveness of the proposed technique, even in the presence of coupled modes.
Power electronic units (PEUs) in electric drivetrains are subjected to vibration loads that may lead to component fatigue through resonance. This research aims to understand the behavior of passive vibration absorbers and to establish a design approach for them. The proposed systematic design of a nonlinear tuned mass damper (NTMD) for PEUs begins with the separate linear experimental analyses of the PEU and passive absorber. This linear approach is possible due to the Hartman–Grobman theorem. Then the nonlinearity is quantified through frequency sweep measurements. A two-degree-of-freedom (DoF) coupled model is developed for the NTMD, which can be used for analyzing certain parameter changes. To manage the load-dependent responses inherent to nonlinear behavior, design constraints on the attenuated bandwidth and absorber stiffness are introduced, providing clear and optimizable targets. By extending classical linear absorber design principles to nonlinear regimes, the proposed method enhances the durability and reliability of PEU components.