Dongshan Xiang

Dr. Dongshan Xiang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2020 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
ZLZijing Lu
Zijing Lu
YJYansong Jiang
Yansong Jiang
PWPeng Wang
Peng Wang
WXWeiwei Xiong
Weiwei Xiong
BQBaoping Qi
Baoping Qi
KZKu Zhai
Ku Zhai

3 February 2020 in Environmental Technology
Verified
Journal Article
Closed access
ZLZijing Lu
Zijing Lu
PWPeng Wang
Peng Wang
WXWeiwei Xiong
Weiwei Xiong
BQBaoping Qi
Baoping Qi
RSRujie Shi
Rujie Shi
KZKu Zhai
Ku Zhai
We have developed a fluorescence quantitative analysis method for the simultaneous detection of Hg2+, Pb2+ and Ag+ based on fluorescently labeled nucleic acid aptamer probes and graphene oxide. By this method, three nucleic acid aptamer probes (PHg, PPb, PAg) were designed. The carboxyl fluorescein (FAM), tetramethyl-6-carboxyrhodamine (TAMRA) and cyanine-5 (Cy-5) were respectively selected as fluorophore of aptamer probes, and graphene oxide (GO) was chosen as quencher. In general, these probes were on free single-stranded state and adsorbed on the surface of GO via π-π interactions, which brought fluorophores of probes and GO into close proximity. Due to the fluorescence resonance energy transfer (FRET) occurred between fluorophores and GO, the fluorescence was quenched and fluorescence signals were all weak. Under the optimal condition, fluorescence intensities of three fluorophores exhibited a good linear dependence on corresponding ions concentration. The detection limit for Hg2+, Pb2+ and Ag+ were 0.2 nmol/L, 0.5 nmol/L and 2 nmol/L (3σ, n = 11). Average recoveries of this method were 97.56 - 104.92%, which indicated the method had a high accuracy and low detection limit. In addition, this proposed method has good selectivity, and there was no crosstalk effect among these probes.

1 November 2014 in Talanta
Verified
Journal Article
Closed access
DXDongshan Xiang
Dongshan Xiang
KZKun Zhai
Kun Zhai
WXWenjun Xiang
Wenjun Xiang
WLWang Lianzhi
Wang Lianzhi

10 March 2017 in Analytical Sciences
Verified
Journal Article
Open access
PDF file
DXDongshan Xiang
Dongshan Xiang
KZKun Zhai
Kun Zhai
QSQiuzhang Sang
Qiuzhang Sang
BSBoan Shi
Boan Shi
XYXiaohong Yang
Xiaohong Yang
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies

20 June 2013 in The Analyst
Verified
Journal Article
Closed access
PDF file
DXDongshan Xiang
Dongshan Xiang
KZKun Zhai
Kun Zhai
LWLian-Zhi Wang
Lian-Zhi Wang
We developed a multiplexed DNA detection method with a composite molecular beacon (MB) probe based on guanine-quenching by synchronous fluorescence analysis. It is demonstrated by two types of tumor-suppressor genes namely exon segments of p16 (T1) and p53 (T2) genes. The composite MB probe includes two loops and two stems, and two fluorophores of 6-carboxyfluorescein group (FAM) and tetramethyl-6-carboxyrhodamine (TAMRA) are connected to the two ends of molecular beacon. Every stem portion of MB include four continuous nucleotides with guanine (G) base as quencher, every loop portion is a probe sequence that is complementary to a corresponding target sequence. In the absence of target DNA, the composite MBs are in the stem-closed form, the fluorescence of FAM and TAMRA are quenched by G bases. At this time, the fluorescence signals of FAM and TAMRA are all very low. In the presence of target DNA, the MBs hybridize with the target DNA and form double-strands, FAM and TAMRA are separated from G bases, and the fluorescence of FAM and TAMRA recovers simultaneously. Thus, the simultaneous detection of two targets of DNA can be realized by measuring fluorescence signals of FAM and TAMRA, respectively. Under the optimum conditions, the fluorescence intensities of FAM and TAMRA all exhibit good linear dependence on their target DNA concentration in the range from 5 × 10−11 to 5.5 × 10−9 M. The detection limit of T1 is 4 × 10−11 M (3σ), and that of T2 is 3 × 10−11 M. This composite MB can be applied to detect the real sample, and can be applied to detect two aleatoric sequences of DNA. Compared with previously reported methods of detecting multiplexed target DNA with MBs, the proposed method has some advantages including easy synthesis of composite MB probes, low detection cost and shorter analytical time.

1 February 2022 in Analytical Sciences
Verified
Journal Article
Closed access
PDF file
PWPeng Wang
Peng Wang
WLWenheng Li
Wenheng Li
ZLZijing Lu
Zijing Lu
WXWeiwei Xiong
Weiwei Xiong
KZKu Zhai
Ku Zhai
DXDongshan Xiang
Dongshan Xiang
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.