Public educational buildings, particularly schools, are often overlooked in energy efficiency initiatives, despite their potential for substantial energy and cost savings. This study presents an integrative, measurement-informed, calibrated model-based approach for assessing and enhancing energy performance in elementary schools located in Israel’s hot-arid climate. By combining multiscale environmental monitoring with a rigorously calibrated Energy Plus simulation model, the study evaluates the impact of three demand-side management (DSM) strategies: night ventilation, external envelope insulation, and a combination of the two. Quantitative results show that night ventilation reduced average indoor temperatures by up to 3.3 °C during peak occupancy hours and led to daily energy savings of 10–15%, equating to approximately 1500–2200 kWh annually per classroom. Envelope insulation further reduced diurnal temperature fluctuations from 7.75 °C to 1.0 °C and achieved an additional 9% energy savings. When combined, the two strategies yielded up to 20% energy savings and improved thermal comfort. The findings provide a transferable framework for evaluating retrofitting options in public buildings, offering actionable insights for policymakers and facility managers aiming to implement scalable, cost-effective energy interventions in educational environments.
This paper presents a multiscale monitoring and management framework designed to enhance energy and indoor environmental performance in retrofitted public schools. The proposed system comprises three layers: (i) a cost-effective sensor network deployed at building, room, and device levels; (ii) a data processing layer supporting redundancy, fault detection, and consistency scoring; and (iii) a role-adaptive interface providing customized dashboards for managers, educators, and students. The framework was deployed in two Mediterranean schools undergoing photovoltaic (PV) integration and envelope rehabilitation. The monitoring layer captures key parameters including temperature, humidity, CO2, PM2.5, occupancy, and circuit-level energy use, enabling multiscale analysis of demand-side behavior and local PV utilization. Data from a full academic year demonstrate a reduction in lighting energy use of up to 22%, classroom-level savings of 10–15%, and an increase in PV self-consumption from 60% to 75%. These improvements were achieved without compromising indoor comfort, as validated by stable environmental conditions aligned with recognized thresholds. The synchronized collection of energy and environmental data allows transparent evaluation of behavioral engagement, operating patterns, and system effectiveness. This research shows that cost-effective, role-adaptive monitoring platforms can support resilience and decarbonization goals in public-sector buildings, particularly where commercial building management systems are financially or technically unfeasible.
Human activities have been the main driver of climate change, primarily due to the burning of fossil fuels. Global progress and computerization impose continuously increasing demand on centralized power distribution networks introducing risks of supply instability. The rehabilitation of existing public infrastructure by renewable on-site power production with Photovoltaics (PV) integrated with Energy Storage Systems (ESS), and Demand Side Management (DSM) strategies is a preferable policy to convert an existing building into an autonomous power unit, thus improving the redundancy of power supply architecture. One of the balks in achieving this goal is insufficient awareness of the public to the impact of the daily decision and behavior habits on the energy performance of the building, which in turn is highly dependent on its eco-structural profile. This research aims to propose a hybrid social-structural (HSS) DSM strategy to reduce energy consumption toward the zero-energy performance of the buildings. Two preliminary schools in southern Israel with significantly different eco-structural profiles were selected as the pilot case study sites to implement and evaluate the suggested DSM approach's quantitative and qualitative effects.