Emilio Romero-Sanchez

Dr. Emilio Romero-Sanchez


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2023 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
EREmilio Romero-Sanchez
Emilio Romero-Sanchez
Antonio Morales-EstebanAntonio Morales-Esteban
Antonio Morales-Esteban
Rita BentoRita Bento
Rita Bento
JNJaime Navarro
Jaime Navarro
Existing heritage buildings can be especially vulnerable to earthquakes. They were designed only considering gravity loads and some of them are located in earthquake prone areas, such as the southwestern Iberian Peninsula. Besides, there is a high uncertainty in the definition of their constructive parameters and complex geometry. Due to that, it is paramount to develop accurate numerical models to obtain a reliable assessment of their seismic behaviour. Given this, the main objective of this manuscript is to analyse the seismic behaviour of the Giralda tower, located in Seville (Spain). It was declared as a Word Heritage Site of Outstanding Universal Value by the UNESCO in 1987. Seville has a moderate seismic hazard, but it has been shown that the soft alluvial strata amplify the seismic action. The tower has a brick and stone masonry structure, which was constructed in several construction phases. A 3D Finite Element Model of the tower has been developed using OpenSees software, employing a 3D CAD model. Modal analyses and nonlinear static analyses have been applied to calibrate and to assess the tower’s seismic behaviour. The results showed significant differences in function of the load pattern. It should be remarked that the boundary conditions have a notable effect upon getting a good calibration of the model. Regarding the damage, it has been found to match the historic records: the ramps would be ruined and, in the outer wall, it would be concentrated near the openings, especially close to the belfry.

17 June 2024 in Engineering Failure Analysis
Verified
Journal Article
Open access
EREmilio Romero-Sanchez
Emilio Romero-Sanchez
María Victoria Requena García de la CruzMaría Victoria Requena García de la Cruz
María Victoria Requena García de la Cruz
AMAntonio Morales-Esteban
Antonio Morales-Esteban

27 April 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
JRJaime de Miguel Rodríguez
Jaime de Miguel Rodríguez
Antonio Morales-EstebanAntonio Morales-Esteban
Antonio Morales-Esteban
María Victoria Requena García de la CruzMaría Victoria Requena García de la Cruz
María Victoria Requena García de la Cruz
BBBeatriz Zapico Blanco
Beatriz Zapico Blanco
MSMaría-Luisa Segovia-Verjel
María-Luisa Segovia-Verjel
João EstêvãoJoão Estêvão
João Estêvão
Capacity curves obtained from nonlinear static analyses are widely used to perform seismic assessments of structures as an alternative to dynamic analysis. This paper presents a novel ‘en masse’ method to assess the seismic vulnerability of urban areas swiftly and with the accuracy of mechanical methods. At the core of this methodology is the calculation of the capacity curves of low-rise reinforced concrete buildings using neural networks, where no modeling of the building is required. The curves are predicted with minimal error, needing only basic geometric and material parameters of the structures to be specified. As a first implementation, a typology of prismatic buildings is defined and a training set of more than 7000 structures generated. The capacity curves are calculated through push-over analysis using SAP2000. The results feature the prediction of 100-point curves in a single run of the network while maintaining a very low mean absolute error. This paper proposes a method that improves current seismic assessment tools by providing a fast and accurate calculation of the vulnerability of large sets of buildings in urban environments.

27 September 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
María Victoria Requena García de la CruzMaría Victoria Requena García de la Cruz
María Victoria Requena García de la Cruz
EREmilio Romero-Sanchez
Emilio Romero-Sanchez
Antonio Morales-EstebanAntonio Morales-Esteban
Antonio Morales-Esteban

20 August 2022 in Buildings
Verified
Journal Article
Open access
PDF file
María Victoria Requena García de la CruzMaría Victoria Requena García de la Cruz
María Victoria Requena García de la Cruz
JDJulia Díaz-Borrego
Julia Díaz-Borrego
EREmilio Romero-Sanchez
Emilio Romero-Sanchez
Antonio Morales-EstebanAntonio Morales-Esteban
Antonio Morales-Esteban
Miguel Ángel CampanoMiguel Ángel Campano
Miguel Ángel Campano
The European building stock is an aging infrastructure, mainly built prior to building codes. Furthermore, 65% of these buildings are located in seismic regions, which need to be both energetic and seismically retrofitted to comply with performance targets. Given this, this manuscript presents integrated constructive solutions that combine both energy efficiency improvement and seismic strengthening. The goal and novelty is to design and to evaluate one-shot, compatible, noninvasive, and complementary solutions applied to the façades of buildings with a minimum cost. To do so, different constraints have been borne in mind: the urban environment, achievable seismic and energy performance targets, and reduced construction costs. The method was applied to an old Spanish neighbourhood constructed in the 1960s. Different retrofitting packages were proposed for an unreinforced masonry case study building. A sensitivity analysis was performed to assess the effects of each configuration. A benefit/cost ratio was proposed to comparatively assess and to rank the solutions. The results of the seismoenergetic performance assessment showed that improving the behaviour of walls leads to higher benefit ratios than improving the openings. However, this latter strategy generates much lower construction costs. Integrating seismic into energetic retrofitting solutions supposes negligible additional costs but can improve the seismic behaviour of buildings by up to 240%. The optimal solution was the addition of higher ratios of steel grids and intermediate profiles in openings while adding thermal insulation in walls and renovating the window frames with PVC and standard 4/6/4 double glazing.

30 May 2025 in Journal of Building Engineering
Verified
Journal Article
Open access
María Victoria Requena García de la CruzMaría Victoria Requena García de la Cruz
María Victoria Requena García de la Cruz
EREmilio Romero-Sanchez
Emilio Romero-Sanchez
Antonio Morales-EstebanAntonio Morales-Esteban
Antonio Morales-Esteban