Buse Çebi Gül

Dr. Buse Çebi Gül


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
BGBuse Çebi Gül
Buse Çebi Gül
FDFatih Demirci
Fatih Demirci
NBNagehan Baki
Nagehan Baki
EBErkan Bahce
Erkan Bahce
MÖMutlu Özcan
Mutlu Özcan
The aim of this study was to compare the wear and fracture resistance of single crowns produced from newly developed 3D printer resins used to produce permanent crowns and currently used composite CAD/CAM discs, after being thermomechanically aged in a chewing simulator. A total of 112 stainless steel die models simulating mandibular left first molars were produced, 8 for each group. Single crowns were produced from 3 different discs (Grandio Voco [GR], breCAM HIPC [HC], and Shofu HC [SF]) by CAD/CAM milling method and manufactured from from 4 different permanent composite resins (Nexdent C&B MFH [ND], Permanent Bridge Saremco [PB], VarseoSmile Crownplus [VSC], and Şenertek P-Crown [PC]) using the 3D printing method. Stereomicroscopy, scanning electron microscope (SEM) and Finite Element Method (FEM) analysis was performed. Data were analyzed using ANOVA, paired-t tests and Tukey’s HSD test (alpha = 0.05). As a result of thermomechanical aging, significant difference was found between the groups in wear and fracture resistance (P < .05). The highest wear resistance was found in the VSC group, and the lowest wear resistance in the PC group. As a result of the compression test, the highest fracture resistance was noted in the GR group and the lowest in the PC group. FEM analysis performed to validate fracture experiments showed an 87% similarity to the in-vitro data. The crowns in all groups produced by CAD/CAM milling and 3D printing provided acceptable in vitro wear and fracture resistance for clinical application. The wear and fracture resistance of resin-based materials should be supported by clinical studies.

26 May 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
BGBuse Çebi Gül
Buse Çebi Gül
MGMurat Doğuş Günel
Murat Doğuş Günel
TETan Fırat Eyüboğlu
Tan Fırat Eyüboğlu
MÖMutlu Özcan
Mutlu Özcan
Purpose: This study evaluated whether implant-retained overdentures fabricated using the neutral zone (NZ) technique offer superior long-term oral health related quality of life (OHRQoL) outcomes compared to conventional overdentures (CO) and assess the influence of these techniques on denture stability, patient satisfaction, and maintenance requirements. Materials and methods: This study involved 29 edentulous patients (14 in the NZ group and 15 in the CO group) who received mandibular implant-retained overdentures with a minimum two year follow up. Two implants were placed in the mandible for each patient, and overdentures were fabricated using either conventional methods or the neutral zone concept, all performed by the same clinician and technician. The OHIP-EDENT questionnaire assessed functional, physical, psychological, and social aspects. Statistical analyses compared pre and post treatment scores as well as intergroup differences. Results: Both groups demonstrated significant post-treatment improvement in OHRQoL (p < 0.001). However, no statistically significant difference was observed between the NZ and conventional groups in overall satisfaction, functional outcomes, pain reduction, or psychological and social well-being (p > 0.05). Furthermore, no significant difference was found in prosthesis fracture rates or the frequency of locator replacements (p > 0.05). Conclusions: Implant-retained overdentures, regardless of fabrication technique, significantly improved patient reported outcomes. However, the NZ technique did not provide a significant advantage over the conventional technique in long term OHRQoL or prosthodontic maintenance.


13 June 2026 in Polymers
Verified
Journal Article
Open access
PDF file
Fırat OğuzFırat Oğuz
Fırat Oğuz
SBSabahattin Bor
Sabahattin Bor
BGBuse Çebi Gül
Buse Çebi Gül
HOHandan Göze Oğuz
Handan Göze Oğuz
To evaluate the effects of three different 3D printers, two clear aligner resins, two specimen thicknesses, two lengths, and two geometric designs on the tensile strength and elastic modulus of directly printed clear aligners. Specimens were produced from two orthodontic aligner resins, Clear A (Senertek, Izmir, Turkey) and Tera Harz TA 28 (Graphy Inc., Seoul, Republic of Korea), using three different 3D printers: Ackuretta SOL (LCD), Asiga MAX (DLP), and UNIZ NBEE (LCD). Specimens were designed in two forms (dumbbell, in accordance with ISO 527 3, and flat strip), in two thicknesses (0.5 mm and 1 mm), and in two lengths (short and long), yielding 24 groups with 5 specimens each (n = 120). All specimens were post processed using the Tera Harz Spinner and cured for 25 min under nitrogen atmosphere in the THC 2 MC unit, followed by a 1 min boiling water treatment. Tensile tests were performed on a universal testing machine (Shimadzu Corp., Kyoto, Japan) up to fracture. Maximum force (N) and elastic modulus (N/mm2) were recorded. Data were analyzed using Kruskal–Wallis, Mann–Whitney U, and Aligned Rank Transform ANOVA tests with Dunn post hoc and Bonferroni correction (p < 0.05). Printer type had no significant effect on maximum force (p = 0.357) or elastic modulus (p = 0.052). Resin type (p < 0.001), thickness (p < 0.001), and specimen geometry (p < 0.001) showed significant effects on both parameters. TA 28 specimens exhibited higher mechanical performance than Clear A. Increased thickness produced higher maximum force and elastic modulus values. Flat geometries showed the highest maximum force, while the short dumbbell exhibited the lowest. The long thin dumbbell geometry yielded the highest elastic modulus values. Resin composition, thickness, and specimen geometry are the primary determinants of mechanical performance in directly printed clear aligners, whereas printer type appears to play a limited role.

10 July 2026 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
BGBuse Çebi Gül
Buse Çebi Gül
EBErkan Bahce
Erkan Bahce
AAAdem Atmaca
Adem Atmaca
FKFurkan Kuzudisli
Furkan Kuzudisli
FDFatih Demirci
Fatih Demirci
This study evaluated the effect of pontic volume on the fracture resistance of three-unit metal-ceramic fixed dental prostheses (FDPs) using in vitro fract

19 December 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
BGBuse Çebi Gül
Buse Çebi Gül
CCCan Cebi
Can Cebi
EMErsel Malkoc
Ersel Malkoc
BABurcin Altinsoy
Burcin Altinsoy
EBErkan Bahçe
Erkan Bahçe
AKAyse Karabas
Ayse Karabas