Aneta Gziut-Rudkowska

Dr. Aneta Gziut-Rudkowska

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2003 in Circulation
Verified
Journal Article
Closed access
FPFrancesco Prati
Francesco Prati
TPTomasz Pawłowski
Tomasz Pawłowski
RGRobert Julian Gil
Robert Julian Gil
ALAntonella Labellarte
Antonella Labellarte
AGAneta Gziut-Rudkowska
Aneta Gziut-Rudkowska
ABAlessandro Boccanelli
Alessandro Boccanelli
Background— Intravascular ultrasound (IVUS) studies have shown that a mechanism of plaque compression/embolization contributes toward the poststenting increase in lumen area. The aim of this IVUS study was to compare the mechanisms of lumen enlargement after coronary stenting in 54 consecutive patients with unstable angina (UA) (group 1) and 56 with stable angina (group 2) to verify whether plaque embolization plays a major role in the former. Methods and Results— Both groups underwent the IVUS assessment (speed, 0.5 mm/sec) before the intervention and after stent implantation. The lumen area, the external elastic membrane area, and the plaque+media area (PA) were measured at 0.5-mm intervals. PA reduction in the lesion site was significantly greater in group 1 (−2.50±1.97 versus −0.53±1.43 mm 2 , P <0.001). After stenting, 47% of the lumen area increase in group 1 was obtained by means of PA reduction, and 53% was attributable to external elastic membrane area increase; the corresponding figures in group 2 were 13% and 87% ( P <0.05). Decrease in PA after stenting was the only significant predictor of the MB fraction of creatinine kinase (CK-MB) release in a multiple regression model ( P =0.047). Conclusions— Serial volumetric IVUS assessment revealed in UA lesions a marked poststenting reduction in plaque volume, which is significantly greater than in stable angina and is associated with postprocedural CK-MB release. The decrease in PA during the procedure predicts CK-MB release in a multiple regression model. These findings suggest that stent deployment is often associated with plaque embolization in patients with UA.

1 December 2008 in Polish Archives of Internal Medicine
Verified
Journal Article
Open access
AGAneta Gziut-Rudkowska
Aneta Gziut-Rudkowska
RGRobert Julian Gil
Robert Julian Gil

1 December 2008
Verified
Journal Article
Closed access
AGAneta Gziut-Rudkowska
Aneta Gziut-Rudkowska
RGRobert J Gil
Robert J Gil

9 September 2016 in Polish Heart Journal
Verified
Journal Article
Open access
PDF file
JKJacek Kądziela
Jacek Kądziela
APAleksander Prejbisz
Aleksander Prejbisz
KKKatarzyna Kostka-Jeziorny
Katarzyna Kostka-Jeziorny
DDDariusz Dudek
Dariusz Dudek
KNKrzysztof Narkiewicz
Krzysztof Narkiewicz
AWAdam Witkowski
Adam Witkowski
Background and aim: The assessment of percutaneous renal sympathetic denervation (RDN) efficacy in patients with true-resistant hypertension (true-RH) in a newly established net of Polish centres (RDN-POL Registry). Methods and results: Forty-four patients with true-RH (23 men, mean age 52.3 years) with daytime systolic blood pressure (SBP) in ambulatory blood pressure monitoring (ABPM) ≥ 135 mm Hg, on ≥ three antihypertensive agents, including diuretic, underwent RDN and completed 12-month follow-up. Mean reductions of office SBP/diastolic blood pressure were –23.8/–10.0, –12.5/–4.6, and –12.6/–6.1 mm Hg at 3, 6, and 12 months, respectively (all significant except diastolic at 6 months). Diabetes was the only predictor of office SBP reduction at 6 months (OR 9.6, 95% CI 1.4–66.5, p < 0.05). Mean 24-h SBP change was –8.3 mm Hg at 6 months and –4.6 mm Hg at 12 months. Increased 2 h-glucose in oral glucose tolerance test was the only predictor of 24-h SBP reduction at 6 months (OR 1.24 for 10 mg/dL glucose increase, 95% CI 1.04–1.48, p < 0.05). At 12 months, 24-h SBP change predictors were: baseline office SBP (OR 4.93 for 10 mm Hg SBP increment, 95% CI 1.01–24.1, p < 0.05) and 2 h-glucose (OR 1.47, 95% CI 1.08–2.00, p < 0.05). In ABPM responders, significant reduction of 2 h glucose was found as compared to the non-responders (–45.8 vs. –7.7 mg/dL, p < 0.005). Conclusions: The RDN-POL Registry demonstrated moderate blood pressure decrease after RDN. The predictors of blood pressure reduction were diabetes, 2 h-glucose, and baseline office SBP. Analysis of ABPM responders indicates a probable positive impact of RDN on glycaemic control. Background and aim: The assessment of percutaneous renal sympathetic denervation (RDN) efficacy in patients with true-resistant hypertension (true-RH) in a newly established net of Polish centres (RDN-POL Registry). Methods and results: Forty-four patients with true-RH (23 men, mean age 52.3 years) with daytime systolic blood pressure (SBP) in ambulatory blood pressure monitoring (ABPM) ≥ 135 mm Hg, on ≥ three antihypertensive agents, including diuretic, underwent RDN and completed 12-month follow-up. Mean reductions of office SBP/diastolic blood pressure were –23.8/–10.0, –12.5/–4.6, and –12.6/–6.1 mm Hg at 3, 6, and 12 months, respectively (all significant except diastolic at 6 months). Diabetes was the only predictor of office SBP reduction at 6 months (OR 9.6, 95% CI 1.4–66.5, p < 0.05). Mean 24-h SBP change was –8.3 mm Hg at 6 months and –4.6 mm Hg at 12 months. Increased 2 h-glucose in oral glucose tolerance test was the only predictor of 24-h SBP reduction at 6 months (OR 1.24 for 10 mg/dL glucose increase, 95% CI 1.04–1.48, p < 0.05). At 12 months, 24-h SBP change predictors were: baseline office SBP (OR 4.93 for 10 mm Hg SBP increment, 95% CI 1.01–24.1, p < 0.05) and 2 h-glucose (OR 1.47, 95% CI 1.08–2.00, p < 0.05). In ABPM responders, significant reduction of 2 h glucose was found as compared to the non-responders (–45.8 vs. –7.7 mg/dL, p < 0.005). Conclusions: The RDN-POL Registry demonstrated moderate blood pressure decrease after RDN. The predictors of blood pressure reduction were diabetes, 2 h-glucose, and baseline office SBP. Analysis of ABPM responders indicates a probable positive impact of RDN on glycaemic control.

30 September 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KBKrzysztof Bojakowski
Krzysztof Bojakowski
AGAneta Gziut-Rudkowska
Aneta Gziut-Rudkowska
RGRafał Góra
Rafał Góra
BFBartosz Foroncewicz
Bartosz Foroncewicz
SKStanisław Kaźmierczak
Stanisław Kaźmierczak
PAPiotr Andziak
Piotr Andziak
Background: The management of patent dialysis fistulas in patients after kidney transplantation (KTx) is controversial—the options that are usually considered are the fistula’s closure or observation. Many complications of dialysis fistulas occur in patients after KTx, and immunosuppression increases the risk of fistula aneurysms and hyperkinetic flow. This study aimed to evaluate the results of dialysis fistula aneurysm treatment in patients after KTx and to compare them to procedures performed in an end-stage renal disease (ESRD) dialyzed population. Methods: We enrolled 83 renal transplant recipients and 123 ESRD patients with dialysis fistula aneurysms qualified for surgical revision to this single-center, prospective study. The results of the surgical treatment of dialysis fistula aneurysms were analyzed, and the primary, assisted primary and secondary patency rate, percentage and type of complications were also assessed. Results: For the treatment of dialysis fistula aneurysms in transplant patients, we performed dialysis fistula excisions with fistula closure in 50 patients (60.2%), excision with primary fistula reconstruction (n = 10, 12.0%) or excision with PTFE bypasses (n = 23, 27.7%). Postoperative complications occurred in 11 patients (13.3%) during a follow-up (median follow-up, 36 months), mostly in distant periods (median time after correction procedure, 11.7 months). The most common complication was outflow stenosis, followed by hematoma, dialysis fistula thrombosis and the formation of a new aneurysm and postoperative bleeding, infection and lymphocele. The 12-month primary, primary assisted and secondary patency rates of fistulas corrected by aneurysm excision and primary reconstruction in the KTx group were all 100%; in the control ESRD group, the 12-month primary rate was 70%, and the primary assisted and secondary patency rates were 100%. The 12-month primary, primarily assisted and secondary patency rates after dialysis fistula aneurysm excision combined with PTFE bypass were better in the KTx group than in the control ESRD group (85% vs. 71.8%, 90% vs. 84.5% and 95% vs. 91.7%, respectively). Kaplan–Meier analysis showed a significant difference in primary patency (p = 0.018) and assisted primary (p = 0.018) rates and a strong tendency in secondary patency rates (p = 0.053) between the KTx and ESRD groups after dialysis fistula excisions combined with PTFE bypass. No statistically significant differences in patency rates between fistulas treated by primary reconstruction and reconstructed with PTFE bypass were observed in KTx patients. Conclusions: Reconstructions of dialysis fistula aneurysms give good long-term results, with a low risk of complications. The reconstruction of dialysis fistulas can be an effective treatment method. Thus, this is an attractive option in addition to fistula ligation or observation in patients after KTx. Reconstructions of dialysis fistula aneurysms enable the preservation of the dialysis fistula while reducing various complications.

31 January 2017 in Polish Archives of Internal Medicine
Verified
Journal Article
Closed access
OMOlga Możeńska
Olga Możeńska
MRMarek Rosiak
Marek Rosiak
AGAneta Gziut-Rudkowska
Aneta Gziut-Rudkowska
RGRobert Julian Gil
Robert Julian Gil
DKDariusz A. Kosior
Dariusz A. Kosior