Juan Shan

Dr. Juan Shan

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
JSJuan Shan
Juan Shan
SAS. Kaisar Alam
S. Kaisar Alam
BGBrian Garra
Brian Garra
YZYingtao Zhang
Yingtao Zhang
TATahira Ahmed
Tahira Ahmed

24 May 2018 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Closed access
YDYaodong Du
Yaodong Du
RARania Almajalid
Rania Almajalid
JSJuan Shan
Juan Shan
MZMing Zhang
Ming Zhang
This paper explored the hidden biomedical information from knee magnetic resonance (MR) images for osteoarthritis (OA) prediction. We have computed the cartilage damage index (CDI) information from 36 informative locations on tibiofemoral cartilage compartment from 3-D MR imaging and used principal component analysis (PCA) analysis to process the feature set. Four machine learning methods (artificial neural network (ANN), support vector machine, random forest, and naïve Bayes) were employed to predict the progression of OA, which was measured by the change of Kellgren and Lawrence (KL) grade, Joint Space Narrowing on Medial compartment (JSM) grade, and Joint Space Narrowing on Lateral compartment (JSL) grade. To examine the different effects of medial and lateral informative locations, we have divided the 36-D feature set into a 18-D medial feature set and a 18-D lateral feature set and run the experiment on four classifiers separately. Experiment results showed that the medial feature set generated better prediction performance than the lateral feature set, while using the total 36-D feature set generated the best. PCA analysis is helpful in feature space reduction and performance improvement. For KL grade prediction, the best performance was achieved by ANN with AUC = 0.761 and F-measure = 0.714. For JSM grade prediction, the best performance was achieved by random forest with AUC = 0.785 and F-measure = 0.743, while for JSL grade prediction, the best performance was achieved by ANN with AUC = 0.695 and F-measure = 0.796. As experiment results showing that the informative locations on medial compartment provide more distinguishing features than informative locations on the lateral compartment, it could be considered to select more points from the medial compartment while reducing the number of points from the lateral compartment to improve clinical CDI design.

24 May 2018 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Closed access
WCWen Cao
Wen Cao
NCNicholas Czarnek
Nicholas Czarnek
JSJuan Shan
Juan Shan
LLLin Li
Lin Li
Diabetic retinopathy (DR) is an eye abnormality caused by long term diabetes and it is the most common cause of blindness before the age of 50. Microaneurysms (MAs), resulting from leakage from retinal blood vessels, are early indicators of DR, yielding a large body of diagnostic work focused on automatic detection of MA. However, automated detection of MAs is difficult because (1) the small size of MA lesions and low contrast between the lesion and its retinal background, (2) the large variations in color, brightness and contrast of fundus images, and (3) the high prevalence of false positives in regions with similar intensity values such as blood vessels, noises and non-homogenous background. In this paper, we analyzed MA detectability using small 25 by 25 pixel patches extracted from fundus images in the DIAbetic RETinopathy DataBase - Calibration Level 1 (DIARETDB1). Raw pixel intensities of extracted patches served directly as inputs into the following classifiers: a random forest (RF), a neural network (NN), and a support vector machine (SVM). We also explored the use of two techniques (principal component analysis and random forest feature importance) for reducing input dimensionality. With traditional machine learning methods and leave-10-patients-out cross-validation, our method outperformed a deep learning based MA detection method, with AUC performance improved from 0.962 to 0.985 and F-measure improved from 0.913 to 0.926, using the same DIARETDB1 database. Furthermore, we validated our method on a different dataset – Retinopathy Online Challenge (ROC) dataset. The performance of three classifiers and the pattern with different percentage of principal components are consistent on the two datasets. Especially, we trained the random forest on DIARETDB1 and applied it to ROC; the performance is very similar to that of the random forest trained and tested using crossvalidation on ROC dataset. This result indicates that our method has the potential to generalize to different datasets.

3 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CGCarmine Guida
Carmine Guida
MZMing Zhang
Ming Zhang
JSJuan Shan
Juan Shan
Osteoarthritis (OA) is the most common form of arthritis and can often occur in the knee. While convolutional neural networks (CNNs) have been widely used to study medical images, the application of a 3-dimensional (3D) CNN in knee OA diagnosis is limited. This study utilizes a 3D CNN model to analyze sequences of knee magnetic resonance (MR) images to perform knee OA classification. An advantage of using 3D CNNs is the ability to analyze the whole sequence of 3D MR images as a single unit as opposed to a traditional 2D CNN, which examines one image at a time. Therefore, 3D features could be extracted from adjacent slices, which may not be detectable from a single 2D image. The input data for each knee were a sequence of double-echo steady-state (DESS) MR images, and each knee was labeled by the Kellgren and Lawrence (KL) grade of severity at levels 0–4. In addition to the 5-category KL grade classification, we further examined a 2-category classification that distinguishes non-OA (KL ≤ 1) from OA (KL ≥ 2) knees. Clinically, diagnosing a patient with knee OA is the ultimate goal of assigning a KL grade. On a dataset with 1100 knees, the 3D CNN model that classifies knees with and without OA achieved an accuracy of 86.5% on the validation set and 83.0% on the testing set. We further conducted a comparative study between MRI and X-ray. Compared with a CNN model using X-ray images trained from the same group of patients, the proposed 3D model with MR images achieved higher accuracy in both the 5-category classification (54.0% vs. 50.0%) and the 2-category classification (83.0% vs. 77.0%). The result indicates that MRI, with the application of a 3D CNN model, has greater potential to improve diagnosis accuracy for knee OA clinically than the currently used X-ray methods.

6 January 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
RARania Almajalid
Rania Almajalid
MZMing Zhang
Ming Zhang
JSJuan Shan
Juan Shan
In the medical sector, three-dimensional (3D) images are commonly used like computed tomography (CT) and magnetic resonance imaging (MRI). The 3D MRI is a non-invasive method of studying the soft-tissue structures in a knee joint for osteoarthritis studies. It can greatly improve the accuracy of segmenting structures such as cartilage, bone marrow lesion, and meniscus by identifying the bone structure first. U-net is a convolutional neural network that was originally designed to segment the biological images with limited training data. The input of the original U-net is a single 2D image and the output is a binary 2D image. In this study, we modified the U-net model to identify the knee bone structures using 3D MRI, which is a sequence of 2D slices. A fully automatic model has been proposed to detect and segment knee bones. The proposed model was trained, tested, and validated using 99 knee MRI cases where each case consists of 160 2D slices for a single knee scan. To evaluate the model’s performance, the similarity, dice coefficient (DICE), and area error metrics were calculated. Separate models were trained using different knee bone components including tibia, femur, patella, as well as a combined model for segmenting all the knee bones. Using the whole MRI sequence (160 slices), the method was able to detect the beginning and ending bone slices first, and then segment the bone structures for all the slices in between. On the testing set, the detection model accomplished 98.79% accuracy and the segmentation model achieved DICE 96.94% and similarity 93.98%. The proposed method outperforms several state-of-the-art methods, i.e., it outperforms U-net by 3.68%, SegNet by 14.45%, and FCN-8 by 2.34%, in terms of DICE score using the same dataset.

20 January 2023 in Neural Computing and Applications
Verified
Journal Article
Closed access
PDF file
CGCarmine Guida
Carmine Guida
MZMing Zhang
Ming Zhang
JSJuan Shan
Juan Shan