Quanhong Shi

Quanhong Shi


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
YWYuetao Wen
Yuetao Wen
KWKunlun Wu
Kunlun Wu
YXYanfeng Xie
Yanfeng Xie
WDWei Dan
Wei Dan
YZYan Zhan
Yan Zhan
QSQuanhong Shi
Quanhong Shi

8 April 2022 in Frontiers in Aging Neuroscience
Verified
Journal Article
Open access
BDBo Deng
Bo Deng
WZWenwen Zhu
Wenwen Zhu
XSXiaochuan Sun
Xiaochuan Sun
YXYanfeng Xie
Yanfeng Xie
WDWei Dan
Wei Dan
LJLi Jiang
Li Jiang
The main purpose of the study was to explore a reliable way to automatically handle emergency cases, such as intracerebral hemorrhage (ICH). Therefore, an artificial intelligence (AI) system, named, H-system, was designed to automatically recognize medical text data of ICH patients and output the treatment plan. Furthermore, the efficiency and reliability of the H-system were tested and analyzed. The H-system, which is mainly based on a pretrained language model Bidirectional Encoder Representations from Transformers (BERT) and an expert module for logical judgment of extracted entities, was designed and founded by the neurosurgeon and AI experts together. All emergency medical text data were from the neurosurgery emergency electronic medical record database (N-eEMRD) of the First Affiliated Hospital of Chongqing Medical University, Chongqing Emergency Medical Center, and Chongqing First People’s Hospital, and the treatment plans of these ICH cases were divided into two types. A total of 1,000 simulated ICH cases were randomly selected as training and validation sets. After training and validating on simulated cases, real cases from three medical centers were provided to test the efficiency of the H-system. Doctors with 1 and 5 years of working experience in neurosurgery (Doctor-1Y and Doctor-5Y) were included to compare with H-system. Furthermore, the data of the H-system, for instance, sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), and the area under the receiver operating characteristics curve (AUC), were calculated and compared with Doctor-1Y and Doctor-5Y. In the testing set, the time H-system spent on ICH cases was significantly shorter than that of doctors with Doctor-1Y and Doctor-5Y. In the testing set, the accuracy of the H-system’s treatment plan was 88.55 (88.16–88.94)%, the specificity was 85.71 (84.99–86.43)%, and the sensitivity was 91.83 (91.01–92.65)%. The AUC value of the H-system in the testing set was 0.887 (0.884–0.891). Furthermore, the time H-system spent on ICH cases was significantly shorter than that of doctors with Doctor-1Y and Doctor-5Y. The accuracy and AUC of the H-system were significantly higher than that of Doctor-1Y. In addition, the accuracy of the H-system was more closed to that of Doctor-5Y. The H-system designed in the study can automatically recognize and analyze medical text data of patients with ICH and rapidly output accurate treatment plans with high efficiency. It may provide a reliable and novel way to automatically and rapidly handle emergency cases, such as ICH.

15 March 2017 in Neurochemical Research
Verified
Journal Article
Closed access
PDF file
YWYuetao Wen
Yuetao Wen
PFPengfei Fu
Pengfei Fu
KWKunlun Wu
Kunlun Wu
KSKaichuang Si
Kaichuang Si
YXYanfeng Xie
Yanfeng Xie
QSQuanhong Shi
Quanhong Shi

4 February 2022 in Clinical Neurophysiology
Verified
Journal Article
Closed access
BYBocheng Yang
Bocheng Yang
XLXinyi Liang
Xinyi Liang
ZWZhimin Wu
Zhimin Wu
XSXiaochuan Sun
Xiaochuan Sun
QSQuanhong Shi
Quanhong Shi
LJLi Jiang
Li Jiang

12 June 2025 in Journal of Medical Internet Research
Verified
Journal Article
Open access
YXYulong Xia
Yulong Xia
JLJie Li
Jie Li
BDBo Deng
Bo Deng
QHQilin Huang
Qilin Huang
FCFengLin Cai
FengLin Cai
LJLi Jiang
Li Jiang
Background: Although much progress has been made in artificial intelligence (AI), several challenges remain substantial obstacles to the development and translation of AI systems into clinical practice. Even large language models, which show excellent performance on various tasks, have progressed slowly in clinical practice tasks. Providing precise and explainable treatment plans with personalized details remains a big challenge for AI systems due to both the highly specialized medical knowledge required and patients’ complicated conditions. Objective: This study aimed to develop an explainable and efficient decision support system named H-SYSTEM to assist neurosurgeons in diagnosing and treating patients with hypertensive intracerebral hemorrhage. The system was designed to address the limitations of existing AI systems by integrating a medical domain knowledge graph to enhance decision-making accuracy and explainability. Methods: The H-SYSTEM consists of 3 main modules: the key named entity recognition (NER) module, the semantic analysis and representation module, and the reasoning module. Furthermore, we constructed a medical domain knowledge graph for hypertensive intracerebral hemorrhage, named HKG, which served as an external knowledge brain of the H-SYSTEM to enhance its text recognition and automated decision-making capability. The HKG was exploited to guide the training of the semantic analysis and representation module and reasoning module, which makes the output of the H-SYSTEM more explainable. To assess the performance of the H-SYSTEM, we compared it with doctors and different large language models. Results: The outputs based on HKG showed reliable performance as compared with neurosurgical doctors, with an overall accuracy of 94.87%. The bidirectional encoder representations from transformers, inflated dilated convolutional neural network, bidirectional long short-term memory, and conditional random fields (BERT-IDCNN-BiLSTM-CRF) model was used as the key NER module of the H-SYSTEM due to its fast convergence and efficient extraction of key named entities, achieved the highest performance among 7 key NER models (precision=92.03, recall=90.22, and F1-score=91.11), significantly outperforming the others. The H-SYSTEM achieved an overall accuracy of 91.74% in treatment plans, showing significant consistency with the gold standard (P<.05), with diagnostic measures achieving 88.18% accuracy, 97.03% area under the curve (AUC), and a κ of 0.874; surgical therapy achieving 98.53% accuracy, 98.53% AUC, and a κ of 0.971; and rescue therapies achieving 89.50% accuracy, 94.67% AUC, and a κ of 0.923 (all P<.05). Furthermore, the H-SYSTEM showed high reliability and efficiency when compared to doctors and ChatGPT, achieving statistically higher accuracy (95.26% vs 91.48%, P<.05). Additionally, the H-SYSTEM achieved a total accuracy of 92.22% (ranging from 91.14% to 95.35%) in treatment plans for 605 additional patients from 6 different medical centers. Conclusions: The H-SYSTEM showed significantly high efficiency and generalization capacity in processing electronic medical records, and it provided explainable and elaborate treatment plans. Therefore, it has the potential to provide neurosurgeons with rapid and reliable decision support, especially in emergency conditions. The knowledge graph–enhanced deep-learning model exhibited excellent performance in the clinical practice tasks.

11 December 2013 in Synapse
Verified
Journal Article
Closed access
PDF file
AZAo Zhan
Ao Zhan
XXXin Xu
Xin Xu
LCLing Chen
Ling Chen
XWXuefeng Wang
Xuefeng Wang
XYXie Yanfeng
Xie Yanfeng
QSQuanhong Shi
Quanhong Shi