Jason Amatoury

Dr. Jason Amatoury


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Chest
Verified
Journal Article
Closed access
JCJayne C. Carberry
Jayne C. Carberry
JAJason Amatoury
Jason Amatoury
DEDanny J. Eckert
Danny J. Eckert

1 December 2016 in SLEEP
Verified
Journal Article
Open access
PDF file
JAJason Amatoury
Jason Amatoury
AAAli Azarbarzin
Ali Azarbarzin
MYMagdy Younes
Magdy Younes
AJAmy S. Jordan
Amy S. Jordan
AWAndrew Wellman
Andrew Wellman
DEDanny J. Eckert
Danny J. Eckert
Study Objectives:. Arousals from sleep vary in duration and intensity. Accordingly, the physiological consequences of different types of arousals may a

1 September 2014 in Clinics in Chest Medicine
Verified
Journal Article
Closed access
MSMudiaga Sowho
Mudiaga Sowho
JAJason Amatoury
Jason Amatoury
JKJason P. Kirkness
Jason P. Kirkness
SPSusheel P. Patil
Susheel P. Patil

1 May 2006 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
JAJason Amatoury
Jason Amatoury
LHLauren Howitt
Lauren Howitt
JWJohn R. Wheatley
John R. Wheatley
AAAlberto Avolio
Alberto Avolio
TATerence C. Amis
Terence C. Amis
Epidemiological studies link habitual snoring and stroke, but mechanisms involved are poorly understood. One previously advanced hypothesis is that transmitted snoring vibration energy may promote carotid atheromatous plaque formation or rupture. To test whether vibration energy is present in carotid artery walls during snoring we developed an animal model in which we examined induced snoring (IS)-associated tissue energy levels. In six male, supine, anesthetized, spontaneously breathing New Zealand White rabbits, we surgically inserted pressure transducer-tipped catheters (Millar) to monitor tissue pressure at the carotid artery bifurcation (PCT) and within the carotid sinus lumen (PCS; artery ligated). Snoring was induced via external compression (sandbag) over the pharyngeal region. Data were analyzed using power spectral analysis for frequency bands above and below 50 Hz. For frequencies below 50 Hz, PCTenergy was 2.2 (1.1–12.3) cmH2O2[median (interquartile range)] during tidal breathing (TB) increasing to 39.0 (2.5–95.0) cmH2O2during IS ( P = 0.05, Wilcoxon's signed-rank test). For frequencies >50 Hz, PCTenergy increased from 9.2 (8.3–10.4) × 10−4cmH2O2during TB to 172.0 (118.0–569.0) × 10−4cmH2O2during IS ( P = 0.03). Concurrently, PCSenergy was 13.4 (8.5–18.0) × 10−4cmH2O2during TB and 151.0 (78.2–278.8) × 10−4cmH2O2during IS ( P < 0.03). The PCSenergy was greater than PCTenergy for the 100–275 Hz bandwidth. In conclusion, during IS there is increased energy around and within the carotid artery, including lower frequency amplification for PCS. These findings may have implications for carotid atherogenesis and/or plaque rupture.

1 November 2010 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
JAJason Amatoury
Jason Amatoury
KKKristina Kairaitis
Kristina Kairaitis
JWJohn R. Wheatley
John R. Wheatley
LBLynne E. Bilston
Lynne E. Bilston
TATerence C. Amis
Terence C. Amis
We studied the impact of wall strain and surrounding pressure on the onset of airflow limitation in a thin-walled “floppy” tube model. A vacuum source-generated steady-state (baseline) airflow (0–350 ml/s) through a thin-walled latex tube (length 80 mm, wall thickness 0.23 mm) enclosed within a rigid, sealed, air-filled, cylindrical chamber while upstream minus downstream pressure, chamber pressure (Pc), and lumen geometry [in-line digital camera; segmentation (Amira 5.2.2) and analysis (Rhinoceros 4) software] were monitored. Longitudinal strain (S; 0–62.5%) and Pc (0–20 cmH2O) combinations were imposed, and Pc associated with onset of 1) reduced airflow and 2) fully developed airflow limitation recorded. At any strain, increasing Pc resulted in a decrease in airflow. Across all baseline airflow, threshold pressure was 1–7 cmH2O for S < 25%, 6–8 cmH2O at S = 25% and 37.5%, and 5–7 cmH2O at S = 50% and 62.5%. Pc associated with fully developed airflow limitation was 4–6 cmH2O for S < 25%, >20 cmH2O at S = 25% (i.e., no flow limitation), 18 cmH2O at S = 37.5%, and 8–12 cmH2O at S = 50% and 62.5%. Lumen area decreased with increasing Pc but was 1) larger at S = 25% and 2) characterized by bifold narrowing at S < 25% and trifold narrowing at S ≥ 25%. In conclusion, tube function was modulated by Pc vs. S interactions, with S = 25% producing trifold lumen narrowing, maximal patency, and no airflow limitation. Findings may have implications for understanding peripharyngeal tissue pressure and pharyngeal wall strain effects on passive pharyngeal airway function in humans.

1 April 2012 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
KKKristina Kairaitis
Kristina Kairaitis
MVManisha Verma
Manisha Verma
JAJason Amatoury
Jason Amatoury
JWJohn R. Wheatley
John R. Wheatley
DWDavid P. White
David P. White
TATerence C. Amis
Terence C. Amis
Increasing lung volume improves upper airway airflow dynamics via passive mechanisms such as reducing upper airway extraluminal tissue pressures (ETP) and increasing longitudinal tension via tracheal displacement. We hypothesized a threshold lung volume for optimal mechanical effects on upper airway airflow dynamics. Seven supine, anesthetized, spontaneously breathing New Zealand White rabbits were studied. Extrathoracic pressure was altered, and lung volume change, airflow, pharyngeal pressure, ETP laterally (ETPlat) and anteriorly (ETPant), tracheal displacement, and sternohyoid muscle activity (EMG%max) monitored. Airflow dynamics were quantified via peak inspiratory airflow, flow limitation upper airway resistance, and conductance. Every 10-ml lung volume increase resulted in caudal tracheal displacement of 2.1 ± 0.4 mm (mean ± SE), decreased ETPlat by 0.7 ± 0.3 cmH2O, increased peak inspiratory airflow of 22.8 ± 2.6% baseline (all P < 0.02), and no significant change in ETPant or EMG%max. Flow limitation was present in most rabbits at baseline, and abolished 15.7 ± 10.5 ml above baseline. Every 10-ml lung volume decrease resulted in cranial tracheal displacement of 2.6 ± 0.4 mm, increased ETPant by 0.9 ± 0.2 cmH2O, ETPlat was unchanged, increased EMG%max of 11.1 ± 0.3%, and a reduction in peak inspiratory airflow of 10.8 ± 1.0%baseline (all P < 0.01). Lung volume, resistance, and conductance relationships were described by exponential functions. In conclusion, increasing lung volume displaced the trachea caudally, reduced ETP, abolished flow limitation, but had little effect on resistance or conductance, whereas decreasing lung volume resulted in cranial tracheal displacement, increased ETP and increased resistance, and reduced conductance, and flow limitation persisted despite increased muscle activity. We conclude that there is a threshold for lung volume influences on upper airway airflow dynamics.