J. Daniel Mena Baladés

Dr. J. Daniel Mena Baladés

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2013 in Energy and Buildings
Verified
Journal Article
Closed access
IMIsmael Rodríguez Maestre
Ismael Rodríguez Maestre
FGFrancisco Javier Gonzalez
Francisco Javier Gonzalez
PGPascual Alvarez Álvarez Gómez
Pascual Alvarez Álvarez Gómez
JBJ. Daniel Mena Baladés
J. Daniel Mena Baladés

27 October 2023 in Metals
Verified
Journal Article
Open access
PDF file
MJMaría Jesús Jiménez-Come
María Jesús Jiménez-Come
FGFrancisco Javier Gonzalez
Francisco Javier Gonzalez
PGPascual Alvarez Álvarez Gómez
Pascual Alvarez Álvarez Gómez
JBJ. Daniel Mena Baladés
J. Daniel Mena Baladés
The main objective established in this work was to develop a model based on artificial neural networks (ANNs) to predict the corrosion status of stainless steel involved in biogas production, analyzing the influence of the material composition and the breakdown potential value. To achieve this objective, an ANN model capable of predicting the corrosion status of the material without the need to perform microscopic analysis on the material surface was proposed. The applicability of the corrosion models was verified via the experimental data considering different factors such as stainless steel composition, biogas environments simulated by artificial solution, temperature, surface finish, and the breakdown potential of the passive layer of stainless steel obtained from electrochemical tests. The optimal prediction performance shown by the model in terms of specificity and sensitivity values were 0.969 and 0.971, respectively, obtaining an accuracy of 0.966. Furthermore, analyzing the influence of the breakdown potential on corrosion modelling, an alternative model was presented capable of predicting the corrosion status automatically, without the need to resort to electrochemical tests for new conditions. The results demonstrated the utility of this technique to be considered in design and maintenance planning tasks for stainless steel structures subjected to localized corrosion in biogas production.

1 October 2016 in Energy and Buildings
Verified
Journal Article
Closed access
JBJuan Luis Foncubierta Blázquez
Juan Luis Foncubierta Blázquez
IMIsmael Rodríguez Maestre
Ismael Rodríguez Maestre
FGFrancisco Javier Gonzalez
Francisco Javier Gonzalez
JBJ. Daniel Mena Baladés
J. Daniel Mena Baladés

16 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
IMIsmael Rodríguez Maestre
Ismael Rodríguez Maestre
JBJuan Luis Foncubierta Blázquez
Juan Luis Foncubierta Blázquez
FGFrancisco Javier Gonzalez
Francisco Javier Gonzalez
JBJ. Daniel Mena Baladés
J. Daniel Mena Baladés
The calculation of sunlit surfaces in a building has always been a relevant aspect in building energy simulation programs. Due to the high computational cost, some programs use algorithms for shading calculation for certain solar positions after discretization of hemispherical sky. The influence of the level of discretization on the estimation of incident direct radiation on building surfaces, as well as on the required computational times, are studied in this work. The direct solar energy on a window for a year, with simulation time steps of five minutes, has been simulated by using an algorithm based on Projection and Clipping Methods. A total of 6144 simulations have been carried out, varying window sizes, window orientations, typologies of shading devices, latitudes and discretization levels of the hemispherical sky. In terms of annual incident solar energy, the results show that maximum error values are about 5% for a low level of angular discretization. Errors up to 22% in hourly incident solar energy have been estimated for some of the configurations analysed. Furthermore, a great number of configurations show errors of shading factor on a window of up to 30%, which could be most relevant in studies of natural lighting. The study also shows that the improvement achieved by the most accurate discretization level implies an increase in computational cost of about 30 times.

2 November 2014 in Journal of Building Performance Simulation
Verified
Journal Article
Closed access
IMIsmael Rodríguez Maestre
Ismael Rodríguez Maestre
JBJ. Daniel Mena Baladés
J. Daniel Mena Baladés
LPLuis Pérez-Lombard
Luis Pérez-Lombard
JGJavier González Gallero
Javier González Gallero

8 August 2013 in Applied Mechanics and Materials
Verified
Journal Article
Closed access
PDF file
JBJ. Daniel Mena Baladés
J. Daniel Mena Baladés
IMIsmael Rodríguez Maestre
Ismael Rodríguez Maestre
PGPascual Alvarez Álvarez Gómez
Pascual Alvarez Álvarez Gómez
JBJuan Luis Foncubierta Blázquez
Juan Luis Foncubierta Blázquez
The ground-coupled heat transfer in buildings is a complex, transient and multidimensional problem. There have been many studies focused to obtain the heat flux in slab and basement foundations. Most of them include the multidimensional effects occur at the perimeter however there are situations in which the heat transfer is mainly one-dimensional. This paper presents a study that aims to establish the accurate of an analytical one-dimensional solution to estimate the ground-coupled heat transfer. Detailed simulation by using finite element software is used to obtain the total heat flux at indoor surface of the building for a whole year. Typical slabs and basements foundations for different dimensions have been analyzed. A correlation to estimate the relative error is proposed.