Charmayne Mary Lee Hughes

Prof. Dr. Charmayne Mary Lee Hughes

orcid

Research Focus & Metrics

Representative Publications

View All Publications
12 November 2019 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
CHCharmayne Mary Lee Hughes
Charmayne Mary Lee Hughes
ALAlexander Louie
Alexander Louie
SSSelena Sun
Selena Sun
CGChloe Gordon-Murer
Chloe Gordon-Murer
GBGashaw Jember Belay
Gashaw Jember Belay
XZXiaorong Zhang
Xiaorong Zhang
The development of context-appropriate sensor technologies could alleviate the significant burden of stroke in Sub-Saharan African rehabilitation clinicians and health care facilities. However, many commercially available wearable sensors are beyond the financial capabilities of the majority of African persons. In this study, we evaluated the concurrent validity of a low-cost wearable sensor (i.e., the outREACH sensor) to measure upper limb movement kinematics of 31 healthy persons, using an 8-camera Vicon motion capture system as the reference standard. The outREACH sensor showed high correlation (r range: 0.808–0.990) and agreement (mean difference range: −1.60 to 1.10) with the reference system regardless of task or kinematic parameter. Moreover, Bland-Altman analyses indicated that there were no significant systematic errors present. This study indicates that upper limb movement kinematics can be accurately measured using the outREACH sensor, and have the potential to enhance stroke evaluation and rehabilitation in sub-Saharan Africa.

30 September 2019 in Health Informatics Journal
Verified
Journal Article
Open access
PDF file
CHCharmayne Mary Lee Hughes
Charmayne Mary Lee Hughes
APAlejandra Padilla
Alejandra Padilla
AHAmy Hintze
Amy Hintze
TRTatiana Mariscal Raymundo
Tatiana Mariscal Raymundo
MSMichael Sera
Michael Sera
MBMoges Baye
Moges Baye
Stroke is the leading cause of adult disability worldwide, with 70 percent of survivors exhibiting residual impairments of the upper limb that require frequent in-person visits to rehabilitation clinic over several months. This study explored rehabilitation clinician’s preferences for design features to be included in an mHealth-enabled app for post-stroke upper limb rehabilitation. Data were collected via online survey, sampling participants from Ethiopia (n = 69) and the United States (n = 75). Survey results indicated that Ethiopian and US rehabilitation clinicians have different opinions about the importance of design features that should be included in a stroke tele-rehabilitation system which are likely due to differences in culture, the availability of human and physical resources, and how the field of rehabilitation is organized and managed. Our results, thus, indicate that mHealth technologies must be tailored to the geographical and cultural context of the end users.

27 June 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
CHCharmayne Mary Lee Hughes
Charmayne Mary Lee Hughes
BTBao Tran
Bao Tran
AMAmir Modan
Amir Modan
XZXiaorong Zhang
Xiaorong Zhang
Stroke is one of the leading causes of death and disability worldwide, with a disproportionate burden represented by low- and middle-income countries (LMICs). To improve post-stroke outcomes in LMICs, researchers have sought to leverage emerging technologies that overcome traditional barriers associated with stroke management. One such technology, inertial measurement units (IMUs), exhibit great potential as a low-cost, portable means to evaluate and monitor patient progress during decentralized rehabilitation protocols. As such, the aim of the present study was to determine the ability of a low-cost single IMU sensor-based wearable system (named the T’ena sensor) to reliably and accurately assess movement quality and efficiency in physically and neurologically healthy adults. Upper limb movement kinematics measured by the T’ena sensor were compared to the gold standard reference system during three functional tasks, and root mean square errors, Pearson’s correlation coefficients, intraclass correlation coefficients, and the Bland Altman method were used to compare kinematic variables of interest between the two systems for absolute accuracy and equivalency. The T’ena sensor and the gold standard reference system were significantly correlated for all tasks and measures (rrange = 0.648—0.947), although less so for the Finger to Nose task (rrange = 0.648—0.894). Results demonstrate that single IMU systems are a valid, reliable, and objective method by which to measure movement kinematics during functional tasks. Context-appropriate enabling technologies specifically designed to address barriers to quality health services in LMICs can accelerate progress towards the United Nations Sustainable Development Goal 3.

22 April 2025 in Frontiers in Aging
Verified
Journal Article
Open access
PDF file
CHCharmayne Mary Lee Hughes
Charmayne Mary Lee Hughes
YZYan Zhang
Yan Zhang
APAli Pourhossein
Ali Pourhossein
TJTerezia Jurasova
Terezia Jurasova
Background: Physical frailty is a pressing public health issue that significantly increases the risk of disability, hospitalization, and mortality. Early and accurate detection of frailty is essential for timely intervention, reducing its widespread impact on healthcare systems, social support networks, and economic stability.Objective: This study aimed to classify frailty status into binary (frail vs. non-frail) and multi-class (frail vs. pre-frail vs. non-frail) categories. The goal was to detect and classify frailty status at a specific point in time. Model development and internal validation were conducted using data from wave 8 of the English Longitudinal Study of Ageing (ELSA), with external validation using wave 6 data to assess model generalizability.Methods: Nine classification algorithms, including Logistic Regression, Random Forest, K-nearest Neighbor, Gradient Boosting, AdaBoost, XGBoost, LightGBM, CatBoost, and Multi-Layer Perceptron, were evaluated and their performance compared.Results: CatBoost demonstrated the best overall performance in binary classification, achieving high recall (0.951), balanced accuracy (0.928), and the lowest Brier score (0.049) on the internal validation set, and maintaining strong performance externally with a recall of 0.950, balanced accuracy of 0.913, and F1-score of 0.951. Multi-class classification was more challenging, with Gradient Boosting emerging as the top model, achieving the highest recall (0.666) and precision (0.663) on the external validation set, with a strong F1-score (0.664) and reasonable calibration (Brier Score = 0.223).Conclusion: Machine learning algorithms show promise for the detection of current frailty status, particularly in binary classification. However, distinguishing between frailty subcategories remains challenging, highlighting the need for improved models and feature selection strategies to enhance multi-class classification accuracy.

17 April 2023 in Frontiers in Medical Technology
Verified
Journal Article
Open access
CHCharmayne Mary Lee Hughes
Charmayne Mary Lee Hughes
AJAndrew Jeffers
Andrew Jeffers
ASArun Sethuraman
Arun Sethuraman
MKMichael Klum
Michael Klum
MTMilly Tan
Milly Tan
VTValerie Tan
Valerie Tan
Introduction: Surgical Site Infection (SSI) is a common healthcare-associated infection that imposes a considerable clinical and economic burden on healthcare systems. Advances in wearable sensors and digital technologies have unlocked the potential for the early detection and diagnosis of SSI, which can help reduce this healthcare burden and lower SSI-associated mortality rates.Methods: In this study, we evaluated the ability of a multi-modal bio-signal system to predict current and developing superficial incisional infection in a porcine model infected with Methicillin Susceptible Staphylococcus Aureus (MSSA) using a bagged, stacked, and balanced ensemble logistic regression machine learning model.Results: Results demonstrated that the expression levels of individual biomarkers (i.e., peri-wound tissue oxygen saturation, temperature, and bioimpedance) differed between non-infected and infected wounds across the study period, with cross-correlation analysis indicating that a change in bio-signal expression occurred 24 to 31 hours before this change was reflected by clinical wound scoring methods employed by trained veterinarians. Moreover, the multi-modal ensemble model indicated acceptable discriminability to detect the presence of a current superficial incisional SSI (AUC = 0.77), to predict an SSI 24 hours in advance of veterinarian-based SSI diagnosis (AUC = 0.80), and to predict an SSI 48 hours in advance of veterinarian-based SSI diagnosis (AUC = 0.74).Discussion: In sum, the results of the current study indicate that non-invasive multi-modal sensor and signal analysis systems have the potential to detect and predict superficial incisional SSIs in porcine subjects under experimental conditions.

12 December 2019 in Frontiers in Neurology
Verified
Journal Article
Open access
PDF file
CHCharmayne Mary Lee Hughes
Charmayne Mary Lee Hughes
MBMoges Baye
Moges Baye
CGChloe Gordon-Murer
Chloe Gordon-Murer
ALAlexander Louie
Alexander Louie
SSSelena Sun
Selena Sun
XZXiaorong Zhang
Xiaorong Zhang
Acquired brain injuries place a significant burden on sub-Saharan African rehabilitation clinicians and health care facilities. While wearable sensors have the potential to alleviate these issues, many are beyond the financial capabilities of the majority of African persons and clinics. To bridge this gap, we have developed a low-cost wrist-worn sensor (the outREACH sensor) capable of accurately measuring upper limb movement kinematics. In this study we evaluated the extent to which the outREACH sensor is sensitive to the hand performing the task (unimpaired, impaired) and level of impairment (mild, moderate) in 14 Ethiopian persons with acquired brain injury (mean age = 51.6 ± 12.2 years, 1 female, 13 male). Participants performed an object manipulation task with both the impaired and the unimpaired limb, and reaching performance was measured using standard kinematic measures (i.e., movement time, spectral arc length, peak velocity, peak acceleration, mean velocity, mean acceleration). Overall, movements were smoother and faster when performed by the patient's unimpaired limb. In contrast, maximum velocity did not differ between the two limbs. Moreover, the outREACH sensor was sensitive to differences in performance-based upper limb impairment. Fugl-Meyer assessment for upper extremity scores were significantly correlated with movement time, spectral arc length, and peak velocity. Upper limb movement kinematics can be accurately measured using the outREACH sensor. The outREACH sensor can be a valuable addition to standardized clinical measures that provides rehabilitation clinicians with information regarding initial upper limb impairment level and changes in function across the rehabilitation lifespan.