Shaun E. Gruenbaum

Dr. Shaun E. Gruenbaum


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2021 in Epilepsia
Verified
Journal Article
Closed access
PDF file
BGBenjamin Fredrick Gruenbaum
Benjamin Fredrick Gruenbaum
MSMani Ratnesh S. Sandhu
Mani Ratnesh S. Sandhu
RBRaphael A. O. Bertasi
Raphael A. O. Bertasi
TBTais G. O. Bertasi
Tais G. O. Bertasi
ASAntonia Schonwald
Antonia Schonwald
GSGerard Sanacora
Gerard Sanacora

4 May 2021 in Neurology
Verified
Journal Article
Closed access
PDF file
RDRoni Dhaher
Roni Dhaher
SGShaun E. Gruenbaum
Shaun E. Gruenbaum
MSMani Ratnesh S. Sandhu
Mani Ratnesh S. Sandhu
SOSigrid Ottestad-Hansen
Sigrid Ottestad-Hansen
NTNathan Tu
Nathan Tu
TETore Eid
Tore Eid
Objective To test the hypothesis that glutamate and GABA are linked to the formation of epilepsy networks and the triggering of spontaneous seizures, we examined seizure initiation/propagation characteristics and neurotransmitter levels during epileptogenesis in a translationally relevant rodent model of mesial temporal lobe epilepsy. Methods The glutamine synthetase (GS) inhibitor methionine sulfoximine was infused into one of the hippocampi in laboratory rats to create a seizure focus. Long-term video-intracranial EEG recordings and brain microdialysis combined with mass spectrometry were used to examine seizure initiation, seizure propagation, and extracellular brain levels of glutamate and GABA. Results All seizures (n = 78 seizures, n = 3 rats) appeared first in the GS-inhibited hippocampus of all animals, followed by propagation to the contralateral hippocampus. Propagation time decreased significantly from 11.65 seconds early in epileptogenesis (weeks 1–2) to 6.82 seconds late in epileptogenesis (weeks 3–4, paired t test, p = 0.025). Baseline extracellular glutamate levels were 11.6-fold higher in the hippocampus of seizure propagation (7.3 µM) vs the hippocampus of seizure onset (0.63 µM, analysis of variance/Fisher least significant difference, p = 0.01), even though the concentrations of the major glutamate transporter proteins excitatory amino acid transporter subtypes 1 and 2 and xCT were unchanged between the brain regions. Finally, extracellular GABA in the seizure focus decreased significantly from baseline several hours before a spontaneous seizure (paired t test/false discovery rate). Conclusion The changes in glutamate and GABA suggest novel and potentially important roles of the amino acids in epilepsy network formation and in the initiation and propagation of spontaneous seizures.

1 October 2019 in Current Opinion in Anaesthesiology
Verified
Journal Article
Closed access
BGBenjamin F. Gruenbaum
Benjamin F. Gruenbaum
SGShaun E. Gruenbaum
Shaun E. Gruenbaum
Purpose of review This article reviews the recent outcome studies that investigated intraoperative neurophysiological monitoring (IONM) during spine, neurovascular and brain tumor surgery. Recent findings Several recent studies have focused on identifying which types of neurosurgical procedures might benefit most from IONM use. Despite conflicting literature regarding its efficacy in improving neurological outcomes, many experts have advocated for the use of IONM in neurosurgery. Several themes have emerged from the recent literature: the entire perioperative team must always work together to ensure adequate communication and intervention; systems and checklists, in which each member of the perioperative team has a clearly defined role, can be useful in the event of a sudden intraoperative changes in electrophysiological signals; regardless of the IONM modality used, any sudden change in electrophysiological signal should prompt an immediate and appropriate intervention; a multimodal IONM approach is often, but not always, advantageous over a single IONM approach. Summary For neurosurgical procedures that can be complicated by neural injury, the use of IONM should be considered according to specific patient and surgical factors. Future studies should focus on improving IONM technology and optimizing sensitivity and specificity for detecting any impending neural damage.

16 July 2019 in CNS Drugs
Verified
Journal Article
Closed access
SGShaun E. Gruenbaum
Shaun E. Gruenbaum
ECEric C. Chen
Eric C. Chen
MSMani Ratnesh Singh Sandhu
Mani Ratnesh Singh Sandhu
KDKetaki Deshpande
Ketaki Deshpande
RDRoni Dhaher
Roni Dhaher
TETore Eid
Tore Eid

1 November 2021 in World Neurosurgery
Verified
Journal Article
Closed access
SGShaun E. Gruenbaum
Shaun E. Gruenbaum
CGChristian S. Guay
Christian S. Guay
BGBenjamin F. Gruenbaum
Benjamin F. Gruenbaum
AKAidos Konkayev
Aidos Konkayev
AFAndrea Falegnami
Andrea Falegnami
FBFederico Bilotta
Federico Bilotta

13 October 2020 in Journal of Neurosurgical Anesthesiology
Verified
Journal Article
Closed access
SGShaun E. Gruenbaum
Shaun E. Gruenbaum
FBFederico Bilotta
Federico Bilotta
TBTais G.O. Bertasi
Tais G.O. Bertasi
RBRaphael A.O. Bertasi
Raphael A.O. Bertasi
WCWilliam E. Clifton
William E. Clifton
AQAlfredo Quinones-Hinojosa
Alfredo Quinones-Hinojosa
Background: During awake craniotomy, securing the patient’s airway might be necessary electively or emergently. The objective of this study was to compare the feasibility of airway management using a laryngeal mask airway (LMA) and 4 alternative airway management techniques in an awake craniotomy simulation. Methods: After completing a questionnaire, 9 anesthesia providers attempted airway management in a cadaver positioned to simulate awake craniotomy conditions. Following the simulation, participants rated and ranked the devices in their order of preference. Results: Only 3 approaches resulted in the successful securement of an airway device for 100% of participants: LMA (median; interquartile range time to secure the airway 6 s, 5 to 10 s), fiberoptic bronchoscopy through an LMA (41 s; 23 to 51 s), and video laryngoscopy (49 s; 43 to 127 s). In contrast, the oral and nasal fiberoptic approaches demonstrated only 44.4% (154.5 s; 134.25 to 182 s) and 55.6% (75 s; 50 to 117 s) success rates, respectively. The LMA was the fastest and most reliable primary method to secure the airway (P=0.001). After the simulation, 100% of participants reported that an LMA would be their first choice for emergency airway management, followed by fiberoptic intubation through the LMA (7 of 9 participants) if the LMA failed to properly seat. Conclusions: We demonstrated that an LMA was the fastest and most reliable primary method to secure an airway in a laterally positioned cadaver with 3-pin skull fixation. Fiberoptic and video laryngoscope airway equipment should be readily available during awake craniotomy procedures, and an attempt to visualize the vocal cords through the LMA should be attempted before removing it for alternative techniques.