Giulia Matteoli

Dr. Giulia Matteoli

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
EQErica Quagliarini
Erica Quagliarini
JWJunbiao Wang
Junbiao Wang
SRSerena Renzi
Serena Renzi
LCLishan Cui
Lishan Cui
LDLuca Digiacomo
Luca Digiacomo
Giulio CaraccioloGiulio Caracciolo
Giulio Caracciolo

25 February 2025 in Communications Biology
Verified
Journal Article
Open access
PDF file
VLValentina De Lorenzi
Valentina De Lorenzi
SGSamuele Ghignoli
Samuele Ghignoli
MBMario Bernardi
Mario Bernardi
GMGiulia Matteoli
Giulia Matteoli
GFGianmarco Ferri
Gianmarco Ferri
Francesco CardarelliFrancesco Cardarelli
Francesco Cardarelli
It is widely accepted that the pH of insulin granules is acidic, and that its active regulation during granule maturation plays a role in the process of insulin secretion by β-cells. Yet, a calibrated measurement of the absolute granule pH with organelle specificity is still lacking. To tackle this issue, we use the genetically encoded E1GFP pH reporter inserted into the C-peptide of proinsulin and expressed in Insulinoma 1E cells. Following verification of correct targeting of the E1GFP reporter in the insulin granules, phasor-based Fluorescence Lifetime Imaging Microscopy (FLIM) is applied to obtain a calibrated and probe-concentration-independent measurement of insulin-granule pH. Our results confirm the acidic nature of insulin granules under maintenance cell culture conditions, with an average luminal pH of ~5.8, and show that acidity is actively maintained, as evidenced by its near-neutralization upon treatment with the vacuolar H+-ATPase inhibitor concanamycin. Additionally, by exploiting the intrinsic spatial resolution of FLIM, we highlight that granules which are proximal to the plasma membrane are slightly more acidic than those which are distal, a difference preserved even during the early phase of glucose-induced insulin secretion. This study lays the foundations for future investigations of granule pH in physiology and disease.

20 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
GMGiulia Matteoli
Giulia Matteoli
PMPasquale Mastella
Pasquale Mastella
EOElisa Ottalagana
Elisa Ottalagana
RNRiccardo Nifosì
Riccardo Nifosì
Luca BellucciLuca Bellucci
Luca Bellucci
SLStefano Luin
Stefano Luin
Prostate-specific antigen (PSA) is a key biomarker for the early detection of prostate cancer recurrence following surgical treatment. In this study, we present a PSA-responsive, aptamer-based switchable aggregate system, named AS2-US-AuNP-Aggregate, composed of ultrasmall gold nanoparticles (US-AuNPs) linked by (partially) pairing oligomers that selectively disassemble in the presence of PSA. The system was optimised also using a previously developed in silico routine and is designed for enhanced detection capabilities and for supporting in vivo applicability. We measured the sizes of the nanosystems by dynamic light scattering (DLS) and their extinction spectra, also in the presence of PSA in simple buffers, in the presence of DNaseI, and under blood-mimicking conditions (filtered plasma), obtaining a response down to 10 fM PSA in buffers and to 1 pM in filtered plasma. Our findings highlight the potential of aptamer-based nanoparticle aggregates as a basis for user-friendly diagnostic tools. Additionally, we discuss key optimisation strategies to further advance their development for in vivo diagnostic applications.

5 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
GMGiulia Matteoli
Giulia Matteoli
PMPasquale Mastella
Pasquale Mastella
EOElisa Ottalagana
Elisa Ottalagana
RNRiccardo Nifosì
Riccardo Nifosì
Luca BellucciLuca Bellucci
Luca Bellucci
SLStefano Luin
Stefano Luin
Prostate-specific antigen (PSA) is a key biomarker for the early detection of prostate cancer recurrence following surgical treatment. In this study, we present a PSA-responsive, aptamer-based switchable aggregate system (AS2-US-AuNPs-Aggregate) composed of ultrasmall gold nanoparticles (US-AuNPs) linked by (partially) pairing oligomers that selectively disassemble in the presence of PSMA. The system was optimized also using a previously developed in-silico routine, and is designed for enhanced sensing capabilities and for supporting in vivo applica-bility. We measured the sizes of the nanosystems by dynamic light scattering (DLS), and their extinction spectra, also in presence of PSA in simple buffers, in the presence of DNAse, and under blood-mimicking conditions (filtered plasma) and We measured a response down to 1 fM PSA in buffers and to 1 pM in filtered plasma. Our findings highlight the potential of aptamer-based nanoparticle aggregates as a basis for us-er-friendly, portable diagnostic tools. Additionally, we discuss key optimization strat-egies to further advance their development for in-vivo diagnostic applications.